Vacuum monitors

The airflow equations presented above are based on the assumption that the soil is a spatially homogeneous porous medium with constant intrinsic permeability. However, in most sites, the vadose zone is heterogeneous. For this reason, design calculations are rarely based on previous hydraulic conductivity measurements. One of the objectives of preliminary field testing is to collect data for the reliable estimation of permeability in the contaminated zone. The field tests include measurements of air flow rates at the extraction well, which are combined with the vacuum monitoring data at several distances to obtain a more accurate estimation of air permeability at the particular site. [Pg.530]

Weekly monitoring of the interstitial space of a double-walled tank may be practiced using pressure monitoring, vacuum monitoring, electronic monitoring, or manual sampling. [Pg.102]

Vacuum monitors which indicate leaks in vacuum systems have now been developed. Leaks are indicated by a gauge and the instrument can discriminate between leaks caused by air, water vapour or contaminating gases. [Pg.86]

A typical straight run section is shown in Fig. 6. All end connections are identical. A casing burst disk is provided and also a valve for vacuum monitoring and maintenance. Liquid line supports, or spacers, are located on 5 ft to 10 ft centers as required. [Pg.298]

A complete solid solubility with a slight negative deviation from Vegard s rule is reported for the concentrational section Smi tEU tBg, revealing the CaB -type (Pm3m) (Konovalova et al., 1982). Samples were prepared by borothermal reduction of oxide mixtures in vacuum. Monitored by X-ray Lm absorption spectroscopy the Sm-valence was found to increase on Sm/Eu substitution from 2.52 (SmB ) to 3.0 in Smo.jEuojB, ... [Pg.508]

This teclnhque can be used both to pennit the spectroscopic detection of molecules, such as H2 and HCl, whose first electronic transition lies in the vacuum ultraviolet spectral region, for which laser excitation is possible but inconvenient [ ], or molecules such as CH that do not fluoresce. With 2-photon excitation, the required wavelengdis are in the ultraviolet, conveniently generated by frequency-doubled dye lasers, rather than 1-photon excitation in the vacuum ultraviolet. Figure B2.3.17 displays 2 + 1 REMPI spectra of the HCl and DCl products, both in their v = 0 vibrational levels, from the Cl + (CHg) CD reaction [ ]. For some electronic states of HCl/DCl, both parent and fragment ions are produced, and the spectrum in figure B2.3.17 for the DCl product was recorded by monitoring mass 2 (D ions. In this case, both isotopomers (D Cl and D Cl) are detected. [Pg.2083]

The KDF filter was first tested in prototype on a coal mine in northern Germany. It was installed in parallel with existing vacuum filters and it produced filter cakes consistendy lower in moisture content by 5 to 7% than the vacuum filters. Two production models have been installed and operated on a coal mine in Belgium. The filter is controlled by a specially developed computer system this consists of two computers, one monitoring the function of the filter and all of the detection devices installed, and the other controlling the filtration process. The system allows optimization of the performance, automatic start-up or shut-down, and can be integrated into the control system of the whole coal washing plant. [Pg.406]

It is often important to quantify the contamination of pore fluid in the unsaturated soil 2one, where monitoring wells are ineffective. In this region, suction cup lysimeters are useful (7). These samplers consist of a porous cup, typically ceramic, having two access tubes which are usually Teflon. One access tube provides a pressure-vacuum, the other discharges the sampled fluid to the surface. The porous cup, typically between 2 and 5 cm in diameter, is attached to a PVC sample accumulation chamber. [Pg.404]

The reaction is completed after 6—8 h at 95°C volatiles, water, and some free phenol are removed by vacuum stripping up to 140—170°C. For resins requiring phenol in only trace amounts, such as epoxy hardeners, steam distillation or steam stripping may be used. Both water and free phenol affect the cure and final resin properties, which are monitored in routine quaHty control testing by gc. OxaHc acid (1—2 parts per 100 parts phenol) does not require neutralization because it decomposes to CO, CO2, and water furthermore, it produces milder reactions and low color. Sulfuric and sulfonic acids are strong catalysts and require neutralization with lime 0.1 parts of sulfuric acid per 100 parts of phenol are used. A continuous process for novolak resin production has been described (31,32). An alternative process for making novolaks without acid catalysis has also been reported (33), which uses a... [Pg.297]

Penetration—Indentation. Penetration and indentation tests have long been used to characterize viscoelastic materials such as asphalt, mbber, plastics, and coatings. The basic test consists of pressing an indentor of prescribed geometry against the test surface. Most instmments have an indenting tip, eg, cone, needle, or hemisphere, attached to a short rod that is held vertically. The load is controlled at some constant value, and the time of indentation is specified the size or depth of the indentation is measured. Instmments have been built which allow loads as low as 10 N with penetration depths less than mm. The entire experiment is carried out in the vacuum chamber of a scanning electron microscope with which the penetration is monitored (248). [Pg.194]

Acoustic Wave Sensors. Another emerging physical transduction technique involves the use of acoustic waves to detect the accumulation of species in or on a chemically sensitive film. This technique originated with the use of quartz resonators excited into thickness-shear resonance to monitor vacuum deposition of metals (11). The device is operated in an oscillator configuration. Changes in resonant frequency are simply related to the areal mass density accumulated on the crystal face. These sensors, often referred to as quartz crystal microbalances (QCMs), have been coated with chemically sensitive films to produce gas and vapor detectors (12), and have been operated in solution as Hquid-phase microbalances (13). A dual QCM that has one smooth surface and one textured surface can be used to measure both the density and viscosity of many Hquids in real time (14). [Pg.391]

Shorter-wavelength radiation promotes transitions between electronic orbitals in atoms and molecules. Valence electrons are excited in the near-uv or visible. At higher energies, in the vacuum uv (vuv), inner-shell transitions begin to occur. Both regions are important to laboratory spectroscopy, but strong absorption by make the vuv unsuitable for atmospheric monitoring. Electronic transitions in molecules are accompanied by stmcture... [Pg.311]

Fig. 4. Schematic of an ultrahigh vacuum molecular beam epitaxy (MBE) growth chamber, showing the source ovens from which the Group 111—V elements are evaporated the shutters corresponding to the required elements, such as that ia front of Source 1, which control the composition of the grown layer an electron gun which produces a beam for reflection high energy electron diffraction (rheed) and monitors the crystal stmcture of the growing layer and the substrate holder which rotates to provide more uniformity ia the deposited film. After Ref. 14, see text. Fig. 4. Schematic of an ultrahigh vacuum molecular beam epitaxy (MBE) growth chamber, showing the source ovens from which the Group 111—V elements are evaporated the shutters corresponding to the required elements, such as that ia front of Source 1, which control the composition of the grown layer an electron gun which produces a beam for reflection high energy electron diffraction (rheed) and monitors the crystal stmcture of the growing layer and the substrate holder which rotates to provide more uniformity ia the deposited film. After Ref. 14, see text.
For example, in rotary vacuum dryers it is possible to prevent the formation of explosible dust-air mixtures by setting and monitoring a certain partial vacuum (negative pressure). This pressure value must be determined by experiment for each type of dust. With pressures of less than O.I bar, in general, hazardous effects of dust explosions need not be anticipated. If the vacuum system malfunctions, the partial vacuum must be released by inert gas and the instaUation shut down. [Pg.2323]

VACUUM RADIATING DESORPTION AND INFRARED SPECTROMETRY (VRDIR) FOR CONTINUOUS MONITORING OF SUSPENDED PARTICULATE ORGANIC MATTERS IN ATMOSPHERE... [Pg.173]

Monitor vacuum level between source and reaction vessel... [Pg.75]

As discussed in Chapter 2, The Toller Selection Process, evaluating the site s safe work practice procedures should have been a part of the review during the toller selection process. Still, new materials may indicate a need to revise or develop special procedures to address unique chemical and physical hazards. New hazards such as vacuum, ciyogenics, ultra-high pressure, or new rotating equipment could be introduced. Medical monitoring requirements or special handling and spill response procedures for the toll s raw materials and products may indicate a need to write or revise safe work practices. [Pg.88]

Insulating materials and their properties Ageing of insulation Practices of insulation systems Procedure for vacuum pressure impregnation Maintenance of insulation Monitoring the quality of insulation of HT formed coils during manufacturing... [Pg.996]

Air is usually the basic load component to an ejector, and the quantities of water vapor and/or condensable vapor are usually directly proportional to the air load. Unfortunately, no reliable method exists for determining precisely the optimum basic air capacity of ejectors. It is desirable to select a capacity which minimizes the total costs of removing the noncondensable gases which accumulate in a process vacuum system. An oversized ejector costs more and uses unnecessarily large quantities of steam and cooling water. If an ejector is undersized, constant monitoring of air leaks is required to avoid costly upsets. [Pg.198]

Contactless, nondestructive monitoring of band gaps in semiconductors Wide range of temperatures and ambients (air, ultrahigh vacuum) in-situ monitoring of semiconductor growth... [Pg.30]

One of the main uses of RHEED is to monitor crystal struaure during film growth in ultrahigh vacuum. Its ability to distinguish between 2D and 3D struaure gives... [Pg.273]

Clean up all spillages immediately and check for pockets (e.g. in cracks and crevices) by monitoring Decontaminate equipment such as vacuum pumps and glassware prior to service/maintenance... [Pg.132]


See other pages where Vacuum monitors is mentioned: [Pg.89]    [Pg.89]    [Pg.89]    [Pg.89]    [Pg.1677]    [Pg.2709]    [Pg.278]    [Pg.322]    [Pg.347]    [Pg.402]    [Pg.355]    [Pg.527]    [Pg.444]    [Pg.150]    [Pg.350]    [Pg.7]    [Pg.27]    [Pg.383]    [Pg.392]    [Pg.321]    [Pg.408]    [Pg.516]    [Pg.516]    [Pg.766]    [Pg.104]    [Pg.377]    [Pg.372]    [Pg.213]    [Pg.266]    [Pg.956]    [Pg.351]   
See also in sourсe #XX -- [ Pg.86 ]




SEARCH



Automatic protection, monitoring and control of vacuum systems

Monitoring vacuum

Monitoring vacuum

Vacuum monitoring control

Vacuum monitoring mass flow controllers

Vacuum monitoring plasma monitors

© 2024 chempedia.info