Insulating materials and their properties Ageing of insulation Practices of insulation systems Procedure for vacuum pressure impregnation Maintenance of insulation Monitoring the quality of insulation of HT formed coils during manufacturing... [Pg.996]

Section 10.5 provides extensive advice on the precautions to be taken against indirect contact, including a recommendation that separated systems with insulation monitoring facilities should be used for life-support equipment. This is to prevent such equipment being automatically disconnected in the event of an earth fault, which would be an undesirable outcome. [Pg.172]

BE-7S67 Fibre optics for remote monitoring of structural integrity of elevated temperature insulated systems (FORMS) Mr. Manuel Gomea Eitrada Nacional... [Pg.935]

Schematic diagram of a flame ionization detector. Ions and electrons formed in the flame provide an electrically conducting path between the flame at earth potential and an insulated cylindrical metal electrode at high potential. surrounding the flame the flow of current is monitored, amplified, and passed to the recording system. Schematic diagram of a flame ionization detector. Ions and electrons formed in the flame provide an electrically conducting path between the flame at earth potential and an insulated cylindrical metal electrode at high potential. surrounding the flame the flow of current is monitored, amplified, and passed to the recording system.
Because chloroprene is a flammable, polymerisable Hquid with significant toxicity, it must be handled with care even in the laboratory. In commercial quantities, precaution must be taken against temperature rise from dimerisation and polymerisation and possible accumulation of explosive vapor concentrations. Storage vessels for inhibited monomer require adequate cooling capacity and vessel pressure rehef faciUties, with care that the latter are free of polymer deposits. When transportation of monomer is required, it is loaded cold (< — 10° C) into sealed, insulated vessels with careful monitoring of loading and arrival temperature and duration of transit. [Pg.39]

The changes in the optical absorption spectra of conducting polymers can be monitored using optoelectrochemical techniques. The optical spectmm of a thin polymer film, mounted on a transparent electrode, such as indium tin oxide (ITO) coated glass, is recorded. The cell is fitted with a counter and reference electrode so that the potential at the polymer-coated electrode can be controlled electrochemically. The absorption spectmm is recorded as a function of electrode potential, and the evolution of the polymer s band stmcture can be observed as it changes from insulating to conducting (11). [Pg.41]

Electric Tracing An electric tracing system (see Fig. 10-178) consists of an electric heater placed against the pipe under the thermal insulation, the supply of electricity to the tracer, and any control or monitoring system that may be used (optional). The supply of electricity to the tracer usually consists of an electrical panel and electrical conduit or cable trays. Depending on the size or the tracing system and the capacity of the existing electrical system, an additional transformer may be required. [Pg.1014]

Material solidifies Monitor and control temperature in feed system or is too viscous, Heat trace and/or insulate lines and plugs lines. Potential for proper line break procedures exposure while Use personal protective equipment (PPE) correcting, proper lockout-tagout and confined space problem. entry procedures CCPS G-23 CCPS G-29 Fisher 1990... [Pg.95]

Monitoring the quality of insulation of HT formed coils during manufacturing 9/227... [Pg.219]

In a formed coil system each individual coil is pre-formed. insulated and cured, and is made rigid before it is inserted into the slots. The dielectric qualities of the coil insulation are monitored closely during the process of coil formation to ensure the required quality. For procedure and acceptance norms see Section 11.4.9. [Pg.223]

By monitoring the insulation condition of the windings during maintenance, at least once a year, which can be carried out by measuring (a) the polarization index (Section 9.5.3) and (b) the dielectric loss factor, tan S (Section 9.6) and making up the insulation as in Section 9.5.2, when the condition of the insulation is acceptable and only its level is less than permissible. [Pg.242]

The tests for insulation resistance and dielectric loss factor should, however, be carried out on a completed machine also with formed coils to establish reference data for field tests, as noted in Section 9.6. However, these tests on a completed machine with formed coils do not monitor the process quality of insulation. [Pg.252]

This is a test to monitor the quality and dielectric behaviour of the insulating system of high-voltage machines, 5 kV... [Pg.259]

Anodes are connected to the object to be protected or to the transformer-rectifier by insulated conductors that are resistant to mineral oil (e.g., Teflon-coated cable) with a cross-section of 2.5 mm of Cu. The transformer-rectifier must meet the demands according to Ref. 6 and have the capability for monitoring and controlling its operation. The life of the anodes is in every case designed to be at least 15 years. [Pg.305]

Bus bars of a transformer substation must not be directly grounded. They must be connected with rails by at least two insulated cables. Metal sheathing of feeder and return current cables must only then be connected with the rails or bus bar if an increase in anodic corrosion on other buried installations is absolutely excluded. The insulation of all return cables must therefore be monitored regularly. [Pg.350]

Molecular weight, effect on centrifugal sizing, 159 Mollier charts, 27 Monitoring system, 356 Motor, 146 enclosure, 260 equations, 267 insulation, 257 locked rotor torque, 270 selection, 270 service factor, 262 starting characteristics, 270 starting time, 273, 274 synchronous vs induction, 265 variable frequency drives, 27/, 280 voltage, 258 Motors... [Pg.548]

See also Capacitors and Ultracapacitors Electric Motor Systems Electric Power, Generation of Electric Power, System Protection, Control, and Monitoring ol Electric Power, System Reliability and Electric Power Substations Environmental Problems and Energy Use Insulation T ransformers. [Pg.438]

The galvanic probe continuously monitors the corrosion characteristics of the drilling fluid. The probe (Figure 4-473) consists of two dissimilar metal electrodes, usually brass and steel. The electrodes are mounted on, but insulated... [Pg.1312]


See other pages where Monitoring insulation is mentioned: [Pg.95]    [Pg.302]    [Pg.95]    [Pg.302]    [Pg.523]    [Pg.936]    [Pg.105]    [Pg.204]    [Pg.204]    [Pg.442]    [Pg.333]    [Pg.436]    [Pg.152]    [Pg.405]    [Pg.152]    [Pg.2309]    [Pg.56]    [Pg.188]    [Pg.228]    [Pg.260]    [Pg.496]    [Pg.768]    [Pg.288]    [Pg.300]    [Pg.309]    [Pg.348]    [Pg.471]    [Pg.479]    [Pg.496]    [Pg.338]    [Pg.262]    [Pg.372]    [Pg.1044]   


SEARCH



© 2024 chempedia.info