Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Units, battery

Under-the-hood parts, ventilation and air conditioning units, battery boxes, air ducts, air vents, ventilation nozzles, fan blades, fan bases, fan shrouds, heating device housings, belt covers, corrugated sheaths for wires and cables, windscreen washer parts. .. [Pg.87]

Figure 7. Top panels Schematic diagram of 3-D cylindrical battery arrays in parallel row (left) and alternating anode/cathode (right) configurations. Middle panels Isopotential lines between cathode (C) and anode (A) for unit battery cells. Bottom panel Current densities (in arbitrary units, a.u.) at the electrode surfaces as a function of the angle 9 (see middle panel for definition of 9). The area of the cathodes and anodes is equal throughout the diagram. (Reprinted with permission from ref 19. Copyright 2003 Elsevier.)... Figure 7. Top panels Schematic diagram of 3-D cylindrical battery arrays in parallel row (left) and alternating anode/cathode (right) configurations. Middle panels Isopotential lines between cathode (C) and anode (A) for unit battery cells. Bottom panel Current densities (in arbitrary units, a.u.) at the electrode surfaces as a function of the angle 9 (see middle panel for definition of 9). The area of the cathodes and anodes is equal throughout the diagram. (Reprinted with permission from ref 19. Copyright 2003 Elsevier.)...
Within process unit battery limits of processing facilities, potassium bicarbonate dry chemical extinguishers should be provided along main access ways. On elevated structures, the extinguisher locations should be near stairway landings. [Pg.230]

The required protection may be obtained by active, passive, or a combination of both protection systems. For example, steel support located in a fire exposed area within process unit battery limits may be protected by either a fixed water spray system or the application of fire resistant insulating material to the steelwork or possibly both. Note Passive protection is generally the preferable method for protecting structural steel. [Pg.255]

Cable trays outside of process areas or unit battery limits are normally not provided with either passive or active fire protection regardless of size. Small cable trays are usually not fire protected regardless of location when they provide service for ancillary equipment or for equipment designed to fail to a safe state on loss of power, control signal or communication. [Pg.277]

Primary cable trays inside of process areas, process structures, or unit battery limits should be reviewed to determine if their routing or location presents a potential fire exposure. Potential external fire exposures to cable trays are typically at those locations where flammable or combustible liquids or gases are handled, such as ... [Pg.277]

Main banks of aboveground instrument runs in cable trays (such as those coming from the control room and supported on process unit pipe racks) that are located inside process unit battery limits should be considered for fireproofing by one of the following passive methods ... [Pg.279]

There are K times L such unit cells in each unit battery and KLZ unit cells in the entire reactor. The unit cells are labeled 1,2. ..k. .. K in the x direction (oxidant flow), 1,2. .. . .. L in the y direction (fuel flow), and they are stacked along the z direction but not indexed due to the two-dimensional nature of the problem. [Pg.172]

The unit batteries, as shown in Figure 1, are connected in series. The model formulation can easily be extended to cover parallel unit battery configurations. However, all numerical runs were carried out for the series configuration. [Pg.172]

It can be shown that for typical thicknesses of solid electrolyte (say, 100 ym) and porous metal catalyst film (say, lOym), the major source of ohmic resistance (>99%) is the solid electrolyte. The consequence is that the actual dimensionless operating voltage X] is constant along each channel and also constant for all channels electrically connected in parallel (as shown in Figure 1), i.e., constant within each unit battery. This observation significantly simplifies the development of the electron balance equations. [Pg.179]

To obtain a second equation between E and i it is necessary to specify the nature of the electrical connections between the unit batteries. [Pg.180]

Series Connection of Unit Batteries. In this case every second plate in the monolith is not covered with a catalyst-electrode. [Pg.180]

Z unit batteries it can be shown that the electron balance equations (40) and (41) remain valid, but the dimensionless numbers and will change ... [Pg.181]

Resistance of electrical connection between unit batteries, ohm... [Pg.191]

A = 1 for series connection and =. 5 for parallel connection of unit batteries = Dimensionless current density... [Pg.192]

Figure 10 A cross-flow monolith fuel cell consisting of five unit batteries connected in series. Each unit battery consists of 100 unit cells electrically connected in parallel. Dark areas are covered with conductive metal film. (From Ref. 48.)... Figure 10 A cross-flow monolith fuel cell consisting of five unit batteries connected in series. Each unit battery consists of 100 unit cells electrically connected in parallel. Dark areas are covered with conductive metal film. (From Ref. 48.)...
Fig. 2.6 (Top panel) Schematic diagram of hexagonal 2 1 cathode/anode battery array. (Bottom panel) Isopotential lines between cathode (C) and anode (A) for unit battery cell. Reprinted from [9], with permission from Elsevier... Fig. 2.6 (Top panel) Schematic diagram of hexagonal 2 1 cathode/anode battery array. (Bottom panel) Isopotential lines between cathode (C) and anode (A) for unit battery cell. Reprinted from [9], with permission from Elsevier...
The communication system consists of the intercommunication unit, battery, electrical branch assembly, microphone, and bracket. [Pg.370]

In addition to the basic costs described above, there are other indirect investment costs and annual expenses that must be added to obtain the total investment and unit battery costs. Additional investment costs include launch costs (plant start-up, training, and... [Pg.106]

The equipment list This document lists all the items of equipment and buildings by number and description to be included within the unit battery limits. A sample equipment list is given in Exhibit 3-4. [Pg.29]

For maintenance and safety, the principal access to and from most process units is by auxiliary roads, Ideally, the unit battery limits should be positioned 50 ft (15,000 mm) from the centerline of the main plant roads. This allows adequate space for ditch drainage and firefighting facilities and avoids obstructing roads when such items as heat exchanger tube bundles are removed. Access ways or spur roads should be provided within the unit for access to items that require servicing or for components that require removal for off-site repair. Clearance according to project specification should be provided over roads and ac-... [Pg.44]

Apart from building that house equipment (e.g., compressor houses), it is often necessary to position control houses, substations, analyzer houses, and operator shelters within the process unit battery limits. Administration buildings and warehouses are generally located away from process unit areas. Control houses and substations are usually located at the edge of the unit adjacent to a plant road, 50 ft (15,000 mm) from the operating equipment. As seen in Exhibit 3-24, analyzer houses and operator shelters should be located next to the equipment that they service. [Pg.44]

The invert elevation of lines at the process unit battery limit, as preferred by the client. [Pg.308]

In addition to being more environmentally friendly than NiCad batteries, NiMH batteries also have a greater energy density (energy content per unit battery mass), as we can see in Table 18.2. In some cases, a NiMH battery can carry twice the energy of a NiCad battery of the same mass, making NiMH batteries the most common choice for hybrid electric vehicles. [Pg.888]

Main pipe racks should be located outside of process-unit battery limits. Provide spacing from pipe racks to equipment for operation, maintenance, and to reduce involvement from adjacent fires. Process equipment should not be located under pipe racks. [Pg.238]

Racks should be located so locomotives do not traverse within 15 meters of process-unit battery hmits or tank storage. [Pg.247]

Isolation or battery limit valves should be installed in a safe, weU-Ughted, accessible location at the process-unit battery limits. [Pg.248]


See other pages where Units, battery is mentioned: [Pg.2547]    [Pg.245]    [Pg.281]    [Pg.119]    [Pg.174]    [Pg.180]    [Pg.192]    [Pg.2301]    [Pg.426]    [Pg.235]    [Pg.2551]    [Pg.225]    [Pg.426]    [Pg.307]    [Pg.181]    [Pg.9]    [Pg.531]   


SEARCH



United States Advanced Battery

United States Advanced Battery Consortium

United States Advanced Battery Consortium USABC)

Units, battery commercially available

© 2024 chempedia.info