Transducer types

Class WAVEFORM Transducer type Thickness range Accuracy... [Pg.895]

Some vibration analyzers include a user-selected time delay that can automatically be downloaded as part of the measurement route. If this feature is included, the delay can be pre-programmed for the specific transducer that will be used to acquire data. No further adjustment is required until the transducer type is changed. [Pg.691]

Gas pressures in vacuum applications are usually either recorded via membrane transducers, systems that monitor the gas density via partial ionisation of the gas or sensors that make use of the fact that the thermal conductivity or diffusivity of a gas is pressure dependent. The first type of transducer is sensitive to the total gas pressure while the other methods yield gas dependent signals. In terms of application properties such as the response time of the sensor, the sensitivity and the pressure range that the sensor covers are important technical specifications. The response of a membrane pressure sensor to a step-like pressure change is essentially an exponential function characterized by a relaxation time r for a MKS transducer, type Baratron 220 [1], r was determined to be 0.227 s (see Fig. 1), the actual pressure and the value as recorded by the transducer therefore do not match within the error bars given for the sensor until more than a second passed. [Pg.443]

We now describe the different approaches to the combination of MIMs with some of the transducer types outlined above, emphasising especially electrochemical transducers for measurements in solution, since other sensor approaches will be dealt with elsewhere in this volume. [Pg.423]

For example, parameters such as transducer type and pretreatment, enzyme and mediator concentration and their rahos within the film, type of immobihzation matrix, immobihzation parameters, and film thickness are varied. A rahonal optimization approach includes that the main parameters affecting the overah ET pathway and hence the final sensor response have to be investigated in order to find reasonable tools for tuning the performance of the selected biosensor design. [Pg.25]

The development of enzyme membrane sensors for glucose began with the first enzyme electrode constructed by Clark. The sensors developed since differ with respect to the biological component and, even more, with the transducer type used. A common element to all of them is that the biocomponent is fixed in front of the transducer by a semi-permeable membrane. [Pg.91]

These reactions are coupled with a signal transducer using mainly the pH decrease and the reaction enthalpy. Whereas (3-lactamase has been combined with various transducer types, penicillin amidase has been applied only in one enzyme electrode for penicillin (Table 9). [Pg.176]

High importance must also be placed on validation of biosensors and immunosensors from the transducer type point of view. Because the biochemical reaction is very sensitive, only the sensors based on an ampero-metric, fluorescent, or chemiluminescent transducer may be validated. [Pg.94]

Transducer type Transduction mechanism Recognition event Signal... [Pg.142]

General transducer types Analyte generates signal Polymer generates signal... [Pg.687]

Although there are a variety of pressure transducer types available, for most lespiiatory applications the newer solid-state pressure transducers offer the most attractive alternative. Variable-capacitance... [Pg.548]

Transducer type Robustness Temperature sensitivity Dynamic response Total error... [Pg.90]

Sensor type Transducer type Detected gas Threshold sensitivity (ppm) Response time (s)... [Pg.99]

Figures 24, 25, and 26 show some comparisons between left and right side temperatures on the follower plate. In Fig.24 and 25 the long transducer type was used, in Fig.26 the short type (Fig.15). The cam cycle temperature is scanned in Fig.27. Figures 24, 25, and 26 show some comparisons between left and right side temperatures on the follower plate. In Fig.24 and 25 the long transducer type was used, in Fig.26 the short type (Fig.15). The cam cycle temperature is scanned in Fig.27.
Molecularly imprinted polymers have also been applied for bio -sensor development. In this case, the MIP act as specific recognition element linked to a transducer, which generates a signal in response to a binding event taking place at the MIP recognition site. Table 7.5 lists some examples of MIP-based sensors using a variety of transducer types. [Pg.151]

A biosensor consists of three main elements a bioreceptor, a transducer, and a signal processing system (David et al., 2008). Biosensors can be classified by their bioreceptor or their transducer types. The classifications of biosensors based on bioreceptors and transducers are represented in Figure 1.2. [Pg.3]

Xenobiotic compound technique Transducer Type of damage References... [Pg.212]


See other pages where Transducer types is mentioned: [Pg.567]    [Pg.29]    [Pg.419]    [Pg.49]    [Pg.300]    [Pg.188]    [Pg.64]    [Pg.3]    [Pg.155]    [Pg.78]    [Pg.690]    [Pg.691]    [Pg.694]    [Pg.688]    [Pg.904]    [Pg.514]    [Pg.1965]    [Pg.81]    [Pg.49]    [Pg.294]    [Pg.94]    [Pg.342]   
See also in sourсe #XX -- [ Pg.500 ]

See also in sourсe #XX -- [ Pg.243 ]