Loudspeaker type velocity transducer

Fig. 3.16 Schematic drawing of the MIMOS II Mossbauer spectrometer. The position of the loudspeaker type velocity transducer to which both the reference and main Co/Rh sources are attached is shown. The room temperature transmission spectrum for a prototype internal reference standard shows the peaks corresponding to hematite (a-Fe203), a-Fe, and magnetite (Fe304). The internal reference standards for MIMOS II flight units are hematite, magnetite, and metallic iron. The backscatter spectrum for magnetite (from the external CCT (Compositional Calibration Target) on the rover) is also shown... Fig. 3.16 Schematic drawing of the MIMOS II Mossbauer spectrometer. The position of the loudspeaker type velocity transducer to which both the reference and main Co/Rh sources are attached is shown. The room temperature transmission spectrum for a prototype internal reference standard shows the peaks corresponding to hematite (a-Fe203), a-Fe, and magnetite (Fe304). The internal reference standards for MIMOS II flight units are hematite, magnetite, and metallic iron. The backscatter spectrum for magnetite (from the external CCT (Compositional Calibration Target) on the rover) is also shown...
Fe which have full width 2r at 0.2 mm s . Other isotopes are less demanding, e.g., Au, for which the lines are ten times wider. Most spectrometers are equipped with electromechanical Mossbauer velocity transducers of the loudspeaker type. This technique is suitable for velocity variations ranging from less than 1 mm s full scale up to several cm s and covers the whole reach of hyperfine splitting for most of the common isotopes. Kalvius, Kankeleit, Cranshaw, and others [1-5] have been pioneers in the field, who laid foundations for the development of high-precision drives with feedback amplifiers for proper linear velocity scales with high stability and low hum. Other techniques for Doppler modulation have been developed for isotopes with extremely narrow hyperfine lines, e.g., Zn. For such isotopes, piezoelectric transducers are mostly used [6, 7], more details of which are found in Sect. 7.2.1. [Pg.27]

The Mossbauer measurement requires the generation of a precise, controllable relative motion between the source and the absorber. A large variety of drive systems has been developed. The majority of drives work on electromechanical, mechanical, hydrauHc, and piezoelectric principle. The spectrometers can be classified into constant-velodty spectrometers and velocity-sweep spectrometers. The mechanical drives, hke a lead screw or a cam, move with constant velocity. They have advantages for the thermal scan method and because their absolute velocity calibration is straightforward. The velocity-sweep spectrometers are usually of electromechanical nature (like loudspeaker-type transducers) and normally used in conjunction with a multichannel analyzer. The most commonly used M(t) functions are rectangular (constant velocity), triangular (constant acceleration), trapezoidal, and sinusoidal. A typical Mossbauer spectrometer is shown schematically in O Fig. 25.24. [Pg.1428]


See also in sourсe #XX -- [ Pg.56 ]




SEARCH



Transducer types

Transducer, transducers

Transducers velocity

© 2024 chempedia.info