Towers types

Fluidized-Bed Vinegar Reactors. Intimate contact of air A.cetohacter is achieved in fluidized-bed or tower-type systems. Air introduced through perforations in the bottom of each unit suspends the mixture of Hquid and microorganisms within the unit. Air bubbles penetrating the bottom plate keep Jicetobacter m. suspension and active for the ethanol oxidation in the Hquid phase. Addition of a carrier for the bacterial ceUs to the Hquid suspension is reported to improve the performance (58—60). [Pg.410]

The choice between a tower-type and a tank-type reactor for a fluid-fluid reaction is determined in part by the kinetics of the reaction. As described by the two-film model... [Pg.602]

Method-II This method used the bulk polymerisation in a tower-type reactor. Ethylene having trace amount of oxygen is charged to the reactor at the pressure of 1500 atmosphere and 1900°C temperature. [Pg.144]

Figure 3 shows the ozonation for two different types of reactors the 1500-ml. bottle reactor and the 1500-ml. packed tower reactor. There is no marked difference in the reaction rate constants, although the packed tower has a slightly lower rate constant than the bottle. If mass transfer were controlling in the reaction, the great deal of agitation in the packed tower would be expected to increase the value of K, The results, however, do not indicate this. It can be concluded that the ozonation does not need to be conducted in a packed tower type of reactor, and that the rate of solution of ozone is very fast compared to the rate of its reaction with cyanide, and that the rate of reaction is controlling. [Pg.84]

The case study is based on a tower-type bioreactor that uses S. cerevisiae immobilized in pellets with 4% of citric pectin, for production of bioethanol. The bioreactor is divided in four stages with gas separators between them to prevent the CO2 accumulation during the fennentation process because the CO2 release may eventually result in a drop in the fermentation yield. The experiments were performed at 30 °C, pH 4.0, initial substrate concentration of 161.4 g/L, feed flow rate of 40 mL/h, and residence time of 6.12 h. After 40 h of operation, the system has reached a steady state. A diagram of the system is shown in Fig. 1. [Pg.668]

Two tower types will be porting and guyed towers. [Pg.345]

The design used in the industry is the tower-type decomposer wherein graphite lumps (—10 mm diameter) are packed in the tower and sodium amalgam is flashed from the top of the tower. The denuded mercury is recycled to the amalgam cell and caustic soda... [Pg.276]

STATICS MODEL OF TOWER-TYPE REPLACING ROPE SYSTEM... [Pg.408]

Figure 2. Statics model of tower-type replacing rope system. Figure 2. Statics model of tower-type replacing rope system.
Particulates are a pain in many heat recovery devices, but especially in check-erworks and other packed tower type recovery equipment. Dust deposits cause difficulties in furnace operation by choking flow passages, necessitating higher pressure drops to maintain flows of air and poc. The necessary higher pressures can cause leaks of air, poc, and heat through walls and by dampers. [Pg.225]

The "planar loop" extractor provides for shallow to intermediate bed depths and is offered by one American and several European companies. In this type the extractor compartments move along a path in a vertical plane. Chains driven by sprockets are used to move the compartments along the path (around the loop). Vertical tower types of these extractors have also been built and operated successfully however, building and maintenance requirements appear to have prevented their continued use. The horizontally elongated type of loop or belt extractor is offered by two European and one American supplier. The vertically elongated configuration appears to have been abandoned. [Pg.191]

The void spray tower type of scrubber, originally developed by Swift and Co. and further developed by Fisons... [Pg.340]

The downwind instrumentation grid of multiple levels of sensors was defined by three arrays, at 50, 150, and 250 m from the downwind end of the vapor barrier fence. On these downwind array towers Type K thermocouples were positioned at four heights on the 50-and 150-m arrays and three heights on the 250-m array, to measure cloud temperature as it moved downwind. The exeeption to this was the tower located on the centerline of the 150-m array, which had four levels of RTD sensors rather than thermocouples. Between tests 3 and 4, two towers and their associated instrumentation were moved from the 50-m array and added to the 150-m array to increase the width of the 150-m array. This was done based on the wider than anticipated clouds created during the first three experiments. [Pg.523]

The Raba Water Treatment plant takes the raw water by tower-type water intake from reservoir Dobczyce, which has possibility of water intake from a level of the best quality parameters. The... [Pg.718]

The common arrangements are shown schematically in Fig. 7.17. Of the natural-circulation towers (Fig. 7.17n and b) the atmospheric towers depend on prevailing winds for air movement. The natural-draft design [6, 8] ensures more positive air movement even in calm weather by depending upon the displacement of the warm air inside the tower by the cooler outside air. Fairly tall chimneys are then required. Both these tower types must be relatively tall in order to operate at a small wet-bulb-temperature approach. Natural-draft equipment is used commonly in the southwestern United States and in the Middle East, where the humidity is usually low, in parts of Europe where air temperatures are generally low, and with increasing frequency everywhere as energy for fan power becomes more costly. [Pg.259]

Figure 2.17. Heat and material balance summary-Mmospheric tower. Type U. Figure 2.17. Heat and material balance summary-Mmospheric tower. Type U.
Figure 2.22. Heat and material balance summary—atmospheric tower. Type R. Figure 2.22. Heat and material balance summary—atmospheric tower. Type R.
Figure 2.25. Heat and materiai balance summary-atmospheric tower. Type A with two pumparound circuits. [Pg.39]


See other pages where Towers types is mentioned: [Pg.254]    [Pg.267]    [Pg.380]    [Pg.713]    [Pg.292]    [Pg.70]    [Pg.112]    [Pg.81]    [Pg.55]    [Pg.2786]    [Pg.254]    [Pg.267]    [Pg.380]    [Pg.48]    [Pg.63]    [Pg.160]    [Pg.398]    [Pg.345]    [Pg.421]    [Pg.425]    [Pg.617]    [Pg.1414]    [Pg.73]    [Pg.732]    [Pg.130]    [Pg.534]   
See also in sourсe #XX -- [ Pg.23 , Pg.24 , Pg.25 , Pg.26 , Pg.27 , Pg.28 , Pg.29 , Pg.30 , Pg.31 , Pg.32 , Pg.33 , Pg.34 , Pg.35 , Pg.36 , Pg.37 , Pg.38 ]

See also in sourсe #XX -- [ Pg.221 ]




SEARCH



Cooling tower types

Cooling towers types, comparison

Packed towers types

Plate towers types

Types of Towers

© 2024 chempedia.info