We have built a fluidic puiser system that can generate approximately 100 psi peak to peak with 500 gal/min mud flowrate. It is to be used down to 15,000 ft. The surface detector needs a 5-psi peak to peak sine wave for proper phase detection. The following oil-base mud is used ... [Pg.953]

Atomic force microscopes have been built in many different versions, with at least six different ways of measuring the deflection of the cantilever [36, 37, 40-42], The commercially available AFM systems use the double photo detector system shown in Figure 7.17 and described by Meyer and Amer [44], Here, a lens focuses a laser beam on the end of the cantilever, which reflects the beam onto two photo detectors which measure intensities T and f2. When the cantilever bends towards the surface, detector 2 receives more light and the difference (h — h) becomes larger. If the tip is scanned over the sample by means of the x- and y-components of the piezo crystal, the difference signal (T — h)/(h + h)... [Pg.200]

The designs of tank farm level detectors include (1) wire-guided float, (2) servo-operated float, (3) surface detector (plumb-bob), (4) radiation backscatter, (5) radar, (6) HTG, and (7) hybrid gauges. Their ranges go up to 60 m (200 ft). [Pg.461]

Estimates of shifts of spectra in curved crystal geometries are often calculated for an ideal detector located on the Rowland circle. However, the detection surface is usually fiat and therefore cannot lie on the Rowland circle. Detectors located on a fixed length detector arm will additionally travel off the Rowland circle as the Bragg angle is scanned unless the crystal curvature is simultaneously scanned (which raises problems of stress hysteresis). Conventional shifts calculated for detection on the Rowland circle do not agree with shifts at a flat extended detector and this systematic error can be 100-200 ppm for any Johann curved crystal spectrometer. We have incorporated fiat surface detectors located off the Rowland circle into the general theory [18,17]. [Pg.704]

The surface detectors are used to obtain the diffraction figures in x-ray, with the consequence of the considerable decrease of the time required for the reordering of the diffraction figures for the crystals. [Pg.86]

Most electrochemical detectors, such as amperometric and potentiometric detectors, are surface detectors. They respond to substances that are either oxidizable or reducible and the electrical output results from an electron flow caused by the chemical reaction that takes place at the surface of the electrodes (Rao et ah, 2002 Mehrvar and Abdi, 2004 Trojanowicz, 2009). Successful operation of a surface detector requires a reproducible radial concentration distribution. There are several types of flow-through detection cells, each type being characterized by parameters such as the length, diameter, and shape of its detection channel, which determine the laminar character of the liquid flow under the given experimental conditions and the predominant mode of the mass transport within the cell. [Pg.107]

Sand production from loosely consolidated formations may lead to erosion of tubulars and valves and sand-fill in of both the sump of the A/ell and surface separators. In addition, sand may bridge off in the tubing, severely restricting flow. The presence of sand production may be monitored by in-line detectors. If the quantities of sand produced become unacceptable then downhole sand exclusion should be considered (Section 9.7). [Pg.340]

The Zond VD - 96 portable eddy-current flaw detector-tester is an original Russian development possessing heightened sensitivity for the surface defects and high inspection capacity. (Russia patent Xs 2063025. All-Union state standard certificate of Russian Federation JVa 2846 of 14. 07. 97)... [Pg.342]

The eombination in a compact system of an infrared sensor and a laser as excitation source is called a photothermal camera. The surface heating is aehieved by the absorption of the focused beam of a laser. This localisation of the heating permits a three-dimensional heat diffusion in the sample to be examined. The infrared (IR) emission of the surface in the neighbourhood of the heating spot is measured by an infrared detector. A full surface inspection is possible through a video scanning of the excitation and detection spots on the piece to test (figure 1). [Pg.393]

It was found that that in the case of soft beta and X-ray radiation the IPs behave as an ideal gas counter with the 100% absorption efficiency if they are exposed in the middle of exposure range ( 10 to 10 photons/ pixel area) and that the relative uncertainty in measured intensity is determined primarily by the quantum fluctuations of the incident radiation (1). The thermal neutron absorption efficiency of the present available Gd doped IP-Neutron Detectors (IP-NDs) was found to be 53% and 69%, depending on the thicknes of the doped phosphor layer ( 85pm and 135 pm respectively). No substantial deviation in the IP response with the spatial variation over the surface of the IP was found, when irradiated by the homogeneous field of X-rays or neutrons and deviations were dominated by the incident radiation statistics (1). [Pg.507]

The X-ray instrumentation requires a commercial small angle X-ray camera, a standard fine structure X-ray generator and a sample manipulator if scanning is requested. The essential signal is the relative difference between the refraction level Ir and the absorption level Ia. Both levels are measured simultaneously by two scintillation detectors. At fixed angles of deflection this signal depends solely on the inner surface density factor C and thickness d of the sample [2] ... [Pg.558]

The laminography method was developed initially for medical applications as a non-computer layer-by-layer visualization of the human body [1,2]. In this case an inclined initial X-ray beam projects an image of a specific layer of the object to the detector surface with defocusing of the other layers during a synchronous rotation of the object and the detector (Fig. 1). [Pg.568]

The methods and means for ecological diagnostics make rapid strides among all the NDT and TD developing areas. To provide the atmosphere monitoring recently the good results were achieved in the development of surface-acoustics wave sensors (SAW), laser measuring systems, infrared detectors and systems based on other physical principles. [Pg.912]

The most widely used experimental method for determining surface excess quantities at the liquid-vapor interface makes use of radioactive tracers. The solute to be studied is labeled with a radioisotope that emits weak beta radiation, such as H, C, or One places a detector close to the surface of the solution and measures the intensity of beta radiation. Since the penetration range of such beta emitters is small (a ut 30 mg/cm for C, with most of the adsorption occurring in the first two-tenths of the range), the measured radioactivity corresponds to the surface region plus only a thin layer of solution (about 0.06 mm for C and even less for H). [Pg.77]

Tajima and co-workers [108] determined the surface excess of sodium dode-cyl sulfate by means of the radioactivity method, using tritiated surfactant of specific activity 9.16 Ci/mol. The area of solution exposed to the detector was 37.50 cm. In a particular experiment, it was found that with 1.0 x 10" Af surfactant the surface count rate was 17.0 x 10 counts per minute. Separate calibration showed that of this count was 14.5 X 10 came from underlying solution, the rest being surface excess. It was also determined that the counting efficiency for surface material was 1.1%. Calculate F for this solution. [Pg.93]

Figure Al.7.11. Schematic diagram of a generic surface science experiment. Particles, such as photons, electrons, or ions, are mcident onto a solid surface, while the particles emitted from the surface are collected and measured by the detector. Figure Al.7.11. Schematic diagram of a generic surface science experiment. Particles, such as photons, electrons, or ions, are mcident onto a solid surface, while the particles emitted from the surface are collected and measured by the detector.
The diffraction pattern observed in LEED is one of the most connnonly used fingerprints of a surface structure. Witii XRD or other non-electron diffraction methods, there is no convenient detector tliat images in real time the corresponding diffraction pattern. Point-source methods, like PD, do not produce a convenient spot pattern, but a diffrise diffraction pattern that does not simply reflect the long-range ordermg. [Pg.1766]

In TOF-SARS [9], a low-keV, monoenergetic, mass-selected, pulsed noble gas ion beam is focused onto a sample surface. The velocity distributions of scattered and recoiled particles are measured by standard TOF methods. A chaimel electron multiplier is used to detect fast (>800 eV) neutrals and ions. This type of detector has a small acceptance solid angle. A fixed angle is used between the pulsed ion beam and detector directions with respect to the sample as shown in figure Bl.23.4. The sample has to be rotated to measure ion scattering... [Pg.1805]


See other pages where Surface detectors is mentioned: [Pg.199]    [Pg.48]    [Pg.154]    [Pg.184]    [Pg.219]    [Pg.17]    [Pg.218]    [Pg.515]    [Pg.138]    [Pg.199]    [Pg.48]    [Pg.154]    [Pg.184]    [Pg.219]    [Pg.17]    [Pg.218]    [Pg.515]    [Pg.138]    [Pg.478]    [Pg.656]    [Pg.723]    [Pg.1062]    [Pg.1063]    [Pg.200]    [Pg.309]    [Pg.1165]    [Pg.1264]    [Pg.1307]    [Pg.1313]    [Pg.1328]    [Pg.1630]    [Pg.1631]    [Pg.1781]    [Pg.1783]    [Pg.1786]    [Pg.1791]    [Pg.1800]    [Pg.1800]    [Pg.1806]    [Pg.1807]   
See also in sourсe #XX -- [ Pg.192 , Pg.214 , Pg.221 , Pg.233 , Pg.237 , Pg.383 ]




SEARCH



Beam detectors negative surface ionization

Detectors surface sensing

High resolution surface barrier detectors

Molecular beams surface ionization detector

Silicon surface barrier detector

Silicon surface detector

Surface acoustic wave detector

Surface analysis barrier detectors

Surface barrier detector

Surface ionization detector

Surface potential detector

Surface-enhanced Raman scattering detectors