Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Steam generators, cost

When boilers can handle multiple fuels, fuel selection could be very beneficial in reducing steam generation cost by taking advantage of the market variability in fuel prices. Calculations of steam cost generated by different fuels should reveal incentives for fuel switch. However, maintenance cost and emission regulations must be considered. [Pg.388]

In order to estimate accurately steam generation costs, it is necessary to conplete a steam balance on the plant. An algorithm for carrying out a steam balance for a new facility is listed below. [Pg.238]

The problem with this approach is that if the steam generated in the boilers is at a very high pressure and/or the ratio of power to fuel costs is high, then the value of low-pressure steam can be extremely low or even negative. This is not sensible and discourages efficient use of low-pressure steam, since it leads to low-pressure steam with a value considerably less than its fuel value. [Pg.411]

As of the mid-1990s, many older conventional steam plants have been converted to combined cycle. The old boiler is removed and replaced by a combustion turbine and heat recovery steam generator. Although the cycle efficiency is not as high as completely new plants, substantial capital cost is avoided by the modification and reuse of existing steam turbine and auxiHary equipment. In many combined cycle power plants, steam is injected into the combustors of the combustion turbine to lower peak flame temperatures and consequendy lower NO. ... [Pg.367]

Overall comparison between amine and carbonate at elevated pressures shows that the amine usually removes carbon dioxide to a lower concentration at a lower capital cost but requires more maintenance and heat. The impact of the higher heat requirement depends on the individual situation. In many appHcations, heat used for regeneration is from low temperature process gas, suitable only for boiler feed water heating or low pressure steam generation, and it may not be usefiil in the overall plant heat balance. [Pg.22]

Steam-Generating Facilities These form the second largest investment item for chemical-plant auxiliaiy equipment. Variations in capacity, location indoors or outdoors, the type of fuel used, pressure and temperature levels, and the type of process served have an important effect on actual cost as well as on cost relative to other auxiliaiy items. Package boiler instaUations can be purchased as shop-built units which are assembled, piped, and wired ready to be erected on the owner s foundations. They are available in units up to about 136,000 kg/h (300,000 Ib/h), although units larger than about 45,360... [Pg.872]

The cost estimate should include provisions for any required satellite boiler water analysis laboratories. The central control lab cannot normally handle analyses of widely spread boilers satisfactorily. The designers, while remembering satellite water laboratory facilities for the utilities area, might overlook similar facilities for the steam generation in the process area. [Pg.227]

NOTE All boiler plant operators are urged to meter the MU water consumption as an aid to calculating a material balance. Steam generation rates can be reasonably accurately determined from the fuel consumption because records of fuel costs are always maintained. Daily and weekly BD rates usually can be estimated from the use of a measuring bucket or pipe velocity table. The difference between steam production and MU represents a combination ofBD and loss of CR. [Pg.181]

Traditionally, customers employ water treatment service companies simply as external contractors to assist in the maintenance of clean and efficient waterside surfaces in their various heating, steam generating, cooling, and certain industrial process systems. The customers benefit from genuine improvements in operating efficiency, reductions in maintenance time, and replacement component costs. In addition, where industrial processes are involved they often profit from an added-value, due to an improved product quality or reduction in manufacturing cost. [Pg.994]

If the steam generated in the boilers is at a very high pressure and/or the ratio of power to fuel costs is high, then the value of low-pressure steam can be extremely low... [Pg.27]

The overall efficiency of steam generation and distribution is 60%. Which scheme is most cost-effective, the steam turbine, the gas turbine or the heat pump ... [Pg.385]

However, this is not likely to be the case. In this example, the two boilers might have different fuels, with different fuel costs and different efficiencies, and the gas turbine (perhaps, with supplementary firing) will have completely different characteristics from the steam boilers. Thus, there are degrees of freedom created by multiple steam generation devices with different costs of fuels, different boiler efficiencies and different power generation potential. Individual steam boilers and HRSGs will have minimum and maximum flows. [Pg.499]


See other pages where Steam generators, cost is mentioned: [Pg.334]    [Pg.335]    [Pg.909]    [Pg.871]    [Pg.334]    [Pg.335]    [Pg.909]    [Pg.871]    [Pg.198]    [Pg.408]    [Pg.425]    [Pg.45]    [Pg.220]    [Pg.55]    [Pg.233]    [Pg.234]    [Pg.873]    [Pg.2394]    [Pg.2397]    [Pg.2413]    [Pg.76]    [Pg.226]    [Pg.340]    [Pg.146]    [Pg.405]    [Pg.406]    [Pg.754]    [Pg.754]    [Pg.200]    [Pg.202]    [Pg.29]    [Pg.148]    [Pg.195]    [Pg.26]    [Pg.32]    [Pg.379]    [Pg.494]    [Pg.499]    [Pg.501]    [Pg.501]    [Pg.503]    [Pg.504]   
See also in sourсe #XX -- [ Pg.809 ]




SEARCH



Steam costing

Steam costs

Steam generation

Steam-generator

© 2024 chempedia.info