Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Overall Comparison

Total water usage at manufacturing plants, however, includes many more opera-hons than just the direct use of process water to make products, such as [Pg.324]


Overall comparison between amine and carbonate at elevated pressures shows that the amine usually removes carbon dioxide to a lower concentration at a lower capital cost but requires more maintenance and heat. The impact of the higher heat requirement depends on the individual situation. In many appHcations, heat used for regeneration is from low temperature process gas, suitable only for boiler feed water heating or low pressure steam generation, and it may not be usefiil in the overall plant heat balance. [Pg.22]

Figure 20. Overall comparison of capacity. (Reproduced with permission of the American Institute of Chemical Engineers. Copyright 1994 AlChE. All rights reserved.)... Figure 20. Overall comparison of capacity. (Reproduced with permission of the American Institute of Chemical Engineers. Copyright 1994 AlChE. All rights reserved.)...
Figure 9-17. Overall comparison of capacity at flood for 24-in. tray spacing with random packing. Reproduced with permission of the American Institute of Chemical Engineers, Kister, H. Z., Larson, K. F., Yanagi, T., Chemical Engineering Progress, V. 90., No. 2 (1994) p. 23 all rights reserved. Figure 9-17. Overall comparison of capacity at flood for 24-in. tray spacing with random packing. Reproduced with permission of the American Institute of Chemical Engineers, Kister, H. Z., Larson, K. F., Yanagi, T., Chemical Engineering Progress, V. 90., No. 2 (1994) p. 23 all rights reserved.
Part 1 Overall comparison of both locations and analytical methods for precision and accuracy ... [Pg.171]

Fig. 3 From the run of Fig. 2, as an overall comparison, are shown the CA6 outlet response and the response for a completely mixed system, given by CAiM. Fig. 3 From the run of Fig. 2, as an overall comparison, are shown the CA6 outlet response and the response for a completely mixed system, given by CAiM.
The biofuel yield of different crops is differs, but a more correct analysis also requires consideration of the (fossil) energy inputs needed to seed, harvest, and process the crops, etc. Clearly, the results depend significantly on regional and technology details, but an overall comparison of net energy yield factors is given in Fig. 1. [Pg.391]

Different selections of calibration and test data set may lead to different answers for the errors. In the following, we present results from one random split however, in the final overall comparison (Section 5.8.1.8) the evaluation scheme is repeated 100 times to get an idea of the distribution of the test error for the optimal parameter choice. [Pg.250]

Overall, comparison of the structure data with the natural mutation spectrum of p53 shows that specific DNA binding is closely associated with the function as a tumor suppressor. A disruption of specific DNA binding apparently has serious effects on the tumor suppressing fimction of p53. [Pg.445]

It is very difficult to make an overall comparison of the organic and conventional production... [Pg.307]

The expectation of lower densities for bcc structures is not consistent with the data in Table 4.2. Overall comparisons indicate that the densities for bcc, hep, and ccp structures are about the same, with the bcc structure slightly more likely to be more dense than hep and ccp structures at the same temperatures. The compressibilities of metals are evident from the effects of pressure. For Nd, the hep structure converts to ccp at 50 kbar with a 19% decrease in atomic volume. [Pg.46]

The values of 0 are most important here because a varies from 90° to 70° for M(0-dik)3 and M(dtc)3 complexes, respectively. Hence the amount of twist toward D3h by the 0 criterion is greatest for the M(dtc)3 complexes whereas the ip criterion shows that the M(T)3 complexes are actually twisted slightly more. The smaller average 0 value of the M(dtc)3 complexes results because of the smaller average value of a [73.2 compared with 78.1 for M(T)3]. However, since only three M(T)3 complexes have been structurally characterized, the average values of a, 0 and 0 are not statistically meaningful and overall comparisons with the M(dtc)3 complexes are not valid.1 ... [Pg.131]

Analysis of student interviews showed that those who used the website generally made more incomplete statements and fewer correct statements in the discussion of coordination chemistry than students who did not use the website. In the overall comparison of the students concept maps, the proportions of correct, incorrect, and incomplete statements were almost the same. The students who used the website made overall twice as many links on their concept maps as website nonusers made. This may mean that students who used the website may be thinking about chemistry more or differently and are thus making more statements. [Pg.235]

An overall comparison of the results of tests using brine indicates that ethoxylated alcohols and ethoxylated alcohol sulfates were superior for mobility control in enhanced oil recovery. It was found that the optimum hydrophobe for ethoxylated alcohol is a mixture with an average chain length of about 13 carbon atoms. The degree of ethoxylation is also important. It was found that 6 ethoxy late groups is close to the optimum. The formation of the sulfate ester tended to lessen the effect of chain length and reduce the optimum number of ethoxylate groups to 5. [Pg.404]

Watanabe T, Sugahara J, Yoshimatsu T, Sasaki S, Sugiyama Y, Ishi K, Shibata Y, Kondo Y, Yoshii K, Ueda T, Uesaka M. (2002) Overall comparison of subpicosecond electron beam diagnostics by the polychromator, the interferometer and the femtosecond streak camera. Nuel Inst Meth A 480 315-327. [Pg.158]


See other pages where Overall Comparison is mentioned: [Pg.582]    [Pg.525]    [Pg.170]    [Pg.252]    [Pg.26]    [Pg.314]    [Pg.84]    [Pg.114]    [Pg.195]    [Pg.324]    [Pg.391]    [Pg.146]    [Pg.447]    [Pg.52]    [Pg.52]    [Pg.334]    [Pg.138]    [Pg.345]    [Pg.83]    [Pg.74]    [Pg.484]    [Pg.700]    [Pg.265]    [Pg.132]    [Pg.163]    [Pg.428]   


SEARCH



Comparison of theory with experiment overall crystallization

Overall Production Cost Comparison

Therapeutic overall comparison

© 2024 chempedia.info