Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Standard salt solutions

Isopiestic determination is one of the most commonly used methods for measuring food aw. In this method a sample of known mass is stored in a closed chamber and allowed to reach equilibrium with an atmosphere of known ERH (or equilibrate with a standard of known aw). In the first protocol (see Basic Protocol), a standard salt solution, for which aw is well established, is used to control this atmosphere. The aw of the sample is then determined by equilibration with the resulting atmosphere. In the second protocol (see Alternate Protocol), the isopiestic determination of aw is accomplished by equilibration of the sample with a reference material, for which the relationship between water content and aw is known. The condition of equilibrium is determined by reweighing the sample at intervals until constant mass is reached. The moisture content of the sample is then determined either directly or by calculation from the reference material s original moisture content and change in mass. Unsaturated salt solutions of known ERH can also be used to equilibrate the samples however, this requires estimation of the ERH of the jars at the end of the equilibration by measuring the exact concentration of the salt solution, which may be tedious. [Pg.51]

FIGURE 2.40 Water penetration rate of chitin-Mg silicate and Avicel 200 as a function of particle size (primary axis). Hygroscopicity measurements of chitin-Mg silicate coprecipitate under different humidity conditions, performed using standard salt solutions stored inside desiccators at room temperature for 1 week (secondary axis). [Pg.90]

The salt content is determined by potentiometric titration in a non-aqueous solution in which the conductivity of a solution of crude oil in a polar solvent is compared with that of a series of standard salt solutions in... [Pg.42]

Fig. 17.7. Two experimental techniques for measuring stoichiometric ion activity coefficients in hydrothermal solutions, (a) Determination by measuring difference in vapor pressures between solutions of known total salt concentration and pure water, (b) Isopiestic measurement in which sample solutions containing known weights of salts are equilibrated with a standard solution for which activity coefficients have been independently measured. In a sealed system water activity is everywhere the same at equilibrium measured salt concentrations in each sample container give the desired activity coefficients from the known activity of water in the standard salt solution. Fig. 17.7. Two experimental techniques for measuring stoichiometric ion activity coefficients in hydrothermal solutions, (a) Determination by measuring difference in vapor pressures between solutions of known total salt concentration and pure water, (b) Isopiestic measurement in which sample solutions containing known weights of salts are equilibrated with a standard solution for which activity coefficients have been independently measured. In a sealed system water activity is everywhere the same at equilibrium measured salt concentrations in each sample container give the desired activity coefficients from the known activity of water in the standard salt solution.
Direct Titrations. The most convenient and simplest manner is the measured addition of a standard chelon solution to the sample solution (brought to the proper conditions of pH, buffer, etc.) until the metal ion is stoichiometrically chelated. Auxiliary complexing agents such as citrate, tartrate, or triethanolamine are added, if necessary, to prevent the precipitation of metal hydroxides or basic salts at the optimum pH for titration. Eor example, tartrate is added in the direct titration of lead. If a pH range of 9 to 10 is suitable, a buffer of ammonia and ammonium chloride is often added in relatively concentrated form, both to adjust the pH and to supply ammonia as an auxiliary complexing agent for those metal ions which form ammine complexes. A few metals, notably iron(III), bismuth, and thorium, are titrated in acid solution. [Pg.1167]

BackTitrations. In the performance of aback titration, a known, but excess quantity of EDTA or other chelon is added, the pH is now properly adjusted, and the excess of the chelon is titrated with a suitable standard metal salt solution. Back titration procedures are especially useful when the metal ion to be determined cannot be kept in solution under the titration conditions or where the reaction of the metal ion with the chelon occurs too slowly to permit a direct titration, as in the titration of chromium(III) with EDTA. Back titration procedures sometimes permit a metal ion to be determined by the use of a metal indicator that is blocked by that ion in a direct titration. Eor example, nickel, cobalt, or aluminum form such stable complexes with Eriochrome Black T that the direct titration would fail. However, if an excess of EDTA is added before the indicator, no blocking occurs in the back titration with a magnesium or zinc salt solution. These metal ion titrants are chosen because they form EDTA complexes of relatively low stability, thereby avoiding the possible titration of EDTA bound by the sample metal ion. [Pg.1167]

In a back titration, a slight excess of the metal salt solution must sometimes be added to yield the color of the metal-indicator complex. Where metal ions are easily hydrolyzed, the complexing agent is best added at a suitable, low pH and only when the metal is fully complexed is the pH adjusted upward to the value required for the back titration. In back titrations, solutions of the following metal ions are commonly employed Cu(II), Mg, Mn(II), Pb(II), Th(IV), and Zn. These solutions are usually prepared in the approximate strength desired from their nitrate salts (or the solution of the metal or its oxide or carbonate in nitric acid), and a minimum amount of acid is added to repress hydrolysis of the metal ion. The solutions are then standardized against an EDTA solution (or other chelon solution) of known strength. [Pg.1167]

Slurry contains 35 g of API Standard Evaluation Base Clay per 350 cm saturated salt solution. [Pg.179]

Determination of Na " and Na" ions in raw cosmetic materials was conducted with the developed method of flame photometry. A necessity of development of method of samples preparation arose up in the work process, as this spicily-aromatic raw material contained pectin in amount 0.1-0.5% and that prevented preparation of samples by standard method of extracts dilution and required incineration of analyzed sample, time of analysis was increased in 60 times. It was established that CaCl, solution with the concentration 0,4 % caused destmctions of the carbopol gel. It was established that the addition of 0,1% CaCl, and 0,1% NaCl salts solutions into the system intensified the effect of negative action of these salts onto the gel stmcture and the gel destmcted completely. [Pg.375]

A. Direct titration. The solution containing the metal ion to be determined is buffered to the desired pH (e.g. to PH = 10 with NH4-aq. NH3) and titrated directly with the standard EDTA solution. It may be necessary to prevent precipitation of the hydroxide of the metal (or a basic salt) by the addition of some auxiliary complexing agent, such as tartrate or citrate or triethanolamine. At the equivalence point the magnitude of the concentration of the metal ion being determined decreases abruptly. This is generally determined by the change in colour of a metal indicator or by amperometric, spectrophotometric, or potentiometric methods. [Pg.311]

The procedure involved in the determination of these anions is virtually that discussed in Section 10.58 for the indirect determination of silver. The anion to be determined is precipitated as the silver salt the precipitate is collected and dissolved in a solution of potassium tetracyanonickelate(II) in the presence of an ammonia/ammonium chloride buffer. Nickel ions are liberated and titrated with standard EDTA solution using murexide as indicator ... [Pg.339]

The method may be applied to those anions (e.g. chloride, bromide, and iodide) which are completely precipitated by silver and are sparingly soluble in dilute nitric acid. Excess of standard silver nitrate solution is added to the solution containing free nitric acid, and the residual silver nitrate solution is titrated with standard thiocyanate solution. This is sometimes termed the residual process. Anions whose silver salts are slightly soluble in water, but which are soluble in nitric acid, such as phosphate, arsenate, chromate, sulphide, and oxalate, may be precipitated in neutral solution with an excess of standard silver nitrate solution. The precipitate is filtered off, thoroughly washed, dissolved in dilute nitric acid, and the silver titrated with thiocyanate solution. Alternatively, the residual silver nitrate in the filtrate from the precipitation may be determined with thiocyanate solution after acidification with dilute nitric acid. [Pg.353]

Discussion. Alkali persulphates (peroxydisulphates) can readily be evaluated by adding to their solutions a known excess of an acidified iron(II) salt solution, and determining the excess of iron(II) by titration with standard potassium permanganate solution. [Pg.374]

A similar procedure may also be used for the determination of antimony(V), whilst antimony (III) may be determined like arsenic(III) by direct titration with standard iodine solution (Section 10.113), but in the antimony titration it is necessary to include some tartaric acid in the solution this acts as complexing agent and prevents precipitation of antimony as hydroxide or as basic salt in alkaline solution. On the whole, however, the most satisfactory method for determining antimony is by titration with potassium bromate (Section 10.133). [Pg.398]

Procedure. Prepare four test solutions of phenol by placing 200 mL of boiled and cooled distilled water in each of four stoppered, 500 mL bottles, and adding to each 5g of sodium chloride this assists the extraction procedure by salting out the phenol. Add respectively 5.0, 10.0, 15.0 and 20.0 mL of the standard phenol solution to the four bottles, then adjust the pH of each solution to about 5 by the careful addition of 5M hydrochloric acid (use a test-paper). Add distilled... [Pg.716]

The potentials of the metals in their 1 mol U salt solution are all related to the standard or normal hydrogen electrode (NHE). For the measurement, the hydrogen half-cell is combined with another half-cell to form a galvanic cell. The measured voltage is called the normal potential or standard electrode potential, E° of the metal. If the metals are ranked according to their normal potentials, the resulting order is called the electrochemi-... [Pg.7]

Cherry and Crandall in 1932 (86) used olive oil as substrate with gum acacia as the emufsTfier. This method has served as the basis for a number of modifications that increased the stability of the emulsion, decreased incubation time and gave better precision. When a serum sample is incubated with a stabilized olive oil emulsion, lipase acts at the interface of substrate and water to hydrolyze olive oil into fatty acid plus diglycerides, and to a small extent to monoglycerides and glycerol. The bile salt sodium deoxycholate activates the reaction. These methods measure the liberated fatty acids by titration with a standardized NaOH solution. An indicator such as phenolphatalein, thymolphthalein or methyl red or a pH meter are used to detect the end point. [Pg.213]

Variations Other protocols use high-salt solutions in combination with isopropanol to precipitate RNA from sucrose fractions. Standard proteinase K digestion in the presence of SDS may be used to extract RNA from the precipitated material. [Pg.138]


See other pages where Standard salt solutions is mentioned: [Pg.15]    [Pg.15]    [Pg.2347]    [Pg.2505]    [Pg.2277]    [Pg.2117]    [Pg.2455]    [Pg.2490]    [Pg.2405]    [Pg.2444]    [Pg.2560]    [Pg.2276]    [Pg.2492]    [Pg.15]    [Pg.15]    [Pg.2347]    [Pg.2505]    [Pg.2277]    [Pg.2117]    [Pg.2455]    [Pg.2490]    [Pg.2405]    [Pg.2444]    [Pg.2560]    [Pg.2276]    [Pg.2492]    [Pg.327]    [Pg.444]    [Pg.181]    [Pg.103]    [Pg.216]    [Pg.193]    [Pg.353]    [Pg.375]    [Pg.652]    [Pg.257]    [Pg.25]    [Pg.44]    [Pg.435]   
See also in sourсe #XX -- [ Pg.188 ]




SEARCH



Chromium salts, standardization procedure for solutions

Solutions standard solution

Solutions standardization

Standard Salt Solutions for Humidity

Standard Salt Solutions for Humidity Calibration

Standard Solutions of Acids, Bases, and Salts

Standard solution

Standardized Solutions

© 2024 chempedia.info