Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Spectroscopy spectrophotometers

Photometry Illuminance Irradiance Scattered light intensity Absorption Spectroscopy Spectrophotometer... [Pg.1636]

Kinetic measurements were performed employii UV-vis spectroscopy (Perkin Elmer "K2, X5 or 12 spectrophotometer) using quartz cuvettes of 1 cm pathlength at 25 0.1 C. Second-order rate constants of the reaction of methyl vinyl ketone (4.8) with cyclopentadiene (4.6) were determined from the pseudo-first-order rate constants obtained by followirg the absorption of 4.6 at 253-260 nm in the presence of an excess of 4.8. Typical concentrations were [4.8] = 18 mM and [4.6] = 0.1 mM. In order to ensure rapid dissolution of 4.6, this compound was added from a stock solution of 5.0 )j1 in 2.00 g of 1-propanol. In order to prevent evaporation of the extremely volatile 4.6, the cuvettes were filled almost completely and sealed carefully. The water used for the experiments with MeReOj was degassed by purging with argon for 0.5 hours prior to the measurements. All rate constants were reproducible to within 3%. [Pg.123]

Spectrophotometer Works, /. Chem. Educ. 1979, 56, 681-684. Consult the following sources for more information about reflectance techniques for IR spectroscopy. [Pg.458]

Nuclear Magnetic Resonance Spectroscopy. Bmker s database, designed for use with its spectrophotometers, contains 20,000 C-nmr and H-nmr, as weU as a combined nmr-ms database (66). Sadder Laboratories markets a PC-based system that can search its coUection of 30,000 C-nmr spectra by substmcture as weU as by peak assignments and by fiiU spectmm (64). Other databases include one by Varian and a CD-ROM system containing polymer spectra produced by Tsukuba University, Japan. CSEARCH, a system developed at the University of Vieima by Robien, searches a database of almost 16,000 C-nmr. Molecular Design Limited (MDL) has adapted the Robien database to be searched in the MACCS and ISIS graphical display and search environment (63). Projects are under way to link the MDL system with the Sadder Hbrary and its unique search capabiHties. [Pg.121]

Fig. 19.2 Layout of an infrared spectrophotometer employing a diffraction grating for monochromation. Reproduced by permission from R. C. J. Osland, Principles and Practices of Infrared Spectroscopy, 2nd edn, Philips Ltd, 1985. Fig. 19.2 Layout of an infrared spectrophotometer employing a diffraction grating for monochromation. Reproduced by permission from R. C. J. Osland, Principles and Practices of Infrared Spectroscopy, 2nd edn, Philips Ltd, 1985.
Within the confines of the present volume it is not possible to provide a detailed discussion of instrumentation for atomic fluorescence spectroscopy. An instrument for simultaneous multi-element determination described by Mitchell and Johansson53 has been developed commercially. Many atomic absorption spectrophotometers can be adapted for fluorescence measurements and details are available from the manufacturers. Detailed descriptions of atomic fluorescence spectroscopy are to be found in many of the volumes listed in the Bibliography (Section 21.27). [Pg.800]

Earlier studies using thermal denaturation analysis and spectrophotomet-ric titration with TxA T and CxC-C" containing DNA triplexes showed that coralyne binds strongly to these triplexes by intercalation and does not exhibit a significant sequence-selectivity [222]. In a later study by Morau Allen et al. [217], employing DNase footprinting, thermal denaturation analysis, UV-visible spectrophotometric titrations, circular dichroism and NMR spectroscopy, showed that coralyne is fully intercalated into TxA T triplex DNA whereas in C GxC triplex, it is partially intercalated due to electrostatic repulsion between the cationic alkaloid and the protonated cytosine [217]. Kepler et al. [223] demonstrated that coralyne intercalated to parallel triplex DNA but did not intercalate to antiparallel triplex DNA. Recently Hud and coworkers [219,224] demonstrated that duplex poly(dA) poly(dT) is trans-... [Pg.194]

UV spectroscopy can be used to detect low levels of organic corrosion inhibitors in produced water. An analytic method has been developed using a diode array UV spectrophotometer [630]. [Pg.87]

Retzik, M. and Froehlich, P., Extending the capability of luminescence spectroscopy with a rapid-scanning fluorescence spectrophotometer, Am. Lab., March, 68, 1992. [Pg.54]

The quaternization kinetics were followed by 3H NMR spectroscopy using a JE0L FX-90Q NMR spectrometer. Solvolysis of p nitro-phenylacetate was followed by UV spectroscopy using a Hewlett Packard 8450 A diode array spectrophotometer. [Pg.75]

Infrared spectra were recorded on a Perkin Elmer model 680 spectrophotometer as mulls in nujol or fluorolube. The magnetic susceptibility of the copper complexes was measured from 4.2 to 300 K by the Faraday method . X-ray photoelectron spectroscopy (XPS) was performed with a Perkin Elmer hemispherical spectrometer. [Pg.431]

Samples were characterized by FTIR spectroscopy with a Perkin Elmer (Spectrum BX) spectrometer using KBr pressed disks as matrices. The DRIFT experiments were carried out with a Broker IFS 55 spectrometer equipped with a Thermo Spectra Tech reacting cell. UV-vis Diffuse Reflectance spectra were recorded on a Perkin Elmer Lambda 45 spectrophotometer equipped with a diffuse reflectance attachment. Raman spectra were collected with Perkin Elmer system 2000 NIR FT-Raman using as excitation radiation the 5th harmonic of a diode pumped Nd YAG laser (1065 nm). [Pg.130]

The metal content analysis of the samples was effected by Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES Varian Liberty II Instrument) after microwaves assisted mineralisation in hydrofluoric/hydrochloric acid mixture. Ultraviolet and visible diffuse reflectance spectroscopy (UV-Vis DRS) was carried out in the 200-900 nm range with a Lambda 40 Perkin Elmer spectrophotometer with a BaS04 reflection sphere. HF was used as a reference. Data processing was carried out with Microcal Origin 7.1 software. [Pg.286]

This layer is then analysed directly by internal reflectance infra-red spectroscopy. Since there is no handling of the sample, contamination is reduced to a minimum. However, only infra-red spectral analysis is possible with this system since the material absorbed on the germanium prism is always a mixture of compounds, and since the spectrophotometer used for the production of the spectra is not a high-precision unit, the information coming from this technique is limited. While identification of specific compounds is not usually possible, changes in spectra, which can be related to the time of day, season, or to singular events, can be observed. [Pg.25]

Pierre [60] has reported a study of the characterisation of the surface of oil slicks by infrared reflective spectroscopy. A double-beam spectrophotometer was modified for studying the reflectance spectra (at angles of incidence 45°, 60°, 70°) of oil layers (20-30 xm thick) on the surface of water using pure water as reference. [Pg.387]

Products in the reaction mixture were analyzed by infrared and nmr spectroscopy. IR spectra were obtained on a Perkin-Elmer 521 infrared spectrophotometer. The reaction mixture was first suction filtered through a fine porosity glass frit inside a glove box (Vacuum Atmosphere HE-43-2) under an argon atmosphere, and was placed in NaCl cells (International Crystals, Inc.) of path length 0.1 or 0.5 cm with Teflon stoppers. H nmr spectra... [Pg.265]


See other pages where Spectroscopy spectrophotometers is mentioned: [Pg.173]    [Pg.173]    [Pg.2949]    [Pg.389]    [Pg.445]    [Pg.313]    [Pg.316]    [Pg.417]    [Pg.213]    [Pg.745]    [Pg.32]    [Pg.96]    [Pg.248]    [Pg.878]    [Pg.183]    [Pg.420]    [Pg.507]    [Pg.304]    [Pg.306]    [Pg.313]    [Pg.320]    [Pg.78]    [Pg.76]    [Pg.129]    [Pg.151]    [Pg.156]    [Pg.201]    [Pg.316]    [Pg.15]    [Pg.84]    [Pg.282]   
See also in sourсe #XX -- [ Pg.18 ]




SEARCH



Spectrophotometers

© 2024 chempedia.info