Solid-phase microextraction sampling time

Table 4 Effect of Solid-Phase Microextraction Sampling Time on the Changes of Measured Gas Phase Concentrations Using a lO-gm Polydimethyl Siloxane Fiber... Table 4 Effect of Solid-Phase Microextraction Sampling Time on the Changes of Measured Gas Phase Concentrations Using a lO-gm Polydimethyl Siloxane Fiber...
Lestremau, R, Andersson, F.A., Desauziers, V., Fanlo, J.L. (2003). Evaluation of Solid-Phase Microextraction for Time-Weighted Average Sampling of Volatile Sulfur Compounds at ppb Concentrations. Anal. Chem., 75, 2626-2632. [Pg.270]

Solid-phase microextractions also have been developed. In one approach, a fused silica fiber is placed inside a syringe needle. The fiber, which is coated with a thin organic film, such as poly(dimethyl siloxane), is lowered into the sample by depressing a plunger and exposed to the sample for a predetermined time. The fiber is then withdrawn into the needle and transferred to a gas chromatograph for analysis. [Pg.213]

Solid-phase microextraction eliminates many of the drawbacks of other sample preparation techniques, such as headspace, purge and trap, LLE, SPE, or simultaneous distillation/extraction techniques, including excessive preparation time or extravagant use of high-purity organic solvents. SPME ranks amongst other solvent-free sample preparation methods, notably SBSE (Section 3.5.3) and PT (Section 4.2.2) which essentially operate at room temperature, and DHS (Section 4.2.2),... [Pg.132]

Principles and Characteristics As mentioned already (Section 3.5.2) solid-phase microextraction involves the use of a micro-fibre which is exposed to the analyte(s) for a prespecified time. GC-MS is an ideal detector after SPME extraction/injection for both qualitative and quantitative analysis. For SPME-GC analysis, the fibre is forced into the chromatography capillary injector, where the entire extraction is desorbed. A high linear flow-rate of the carrier gas along the fibre is essential to ensure complete desorption of the analytes. Because no solvent is injected, and the analytes are rapidly desorbed on to the column, minimum detection limits are improved and resolution is maintained. Online coupling of conventional fibre-based SPME coupled with GC is now becoming routine. Automated SPME takes the sample directly from bottle to gas chromatograph. Split/splitless, on-column and PTV injection are compatible with SPME. SPME can also be used very effectively for sample introduction to fast GC systems, provided that a dedicated injector is used for this purpose [69,70],... [Pg.437]

The choice of solid-phase microextraction sorbent phase was shown to be important especially for the amino metabolities of trinitrotoluene and RDX, which were extracted better on polar phases. Although equilibration times were quite lengthy, on the order of 30 min or greater, a sampling time of only 10 min was shown to be sufficient for achieving low part-per-billion (ppb) to part-per-trillion (ppt) detection limits for trinitrotoluene and the amino metabolities in real seawater samples. Solid-phase microextraction was ideal for rapid screening of explosives in seawater samples. [Pg.413]

The time required for quantification of volatiles by both the Basic Protocol and the Alternate Protocol depends on the isolation/extrac-tion procedure chosen. A complete homogenization of the labeled standards with the sample usually requires not more than 30 min and GC-MS analysis is accomplished within 1 hr. In combination with a high-throughput method like solid-phase microextraction, the GC cycle times (-1 hr) become the limiting factor in the quantification of multiple samples by IDAs. [Pg.1022]

Lopez-Avila et al. [107] showed that microwave-assisted extraction of pesticides and polycyclic aromatic hydrocarbons from soil is a viable alternative to Soxhlet extraction and needs a smaller sample volume and extraction time [108,109]. These techniques have also been compared in the case of chlorophenols. Lopez-Avila et al. compared microwave-assisted extraction with electron capture gas chromatography to ELISA for the determination of polychlorinated biphenyls in soils. Both techniques are applicable to field screening and monitoring applications. Microwave-assisted extraction [111, 112] and solid-phase microextraction [113] have been applied to the extraction of pesticides from soil. It was observed by these and other workers [114] that the selectivity of microwave-assisted extraction is highly dependent on the soil composition. [Pg.10]

Supercritical fluid extraction [153,154], accelerated solvent extraction [68] and subcritical fluid extraction [107,155] have been studied. To reduce the equipment cost and the analysis time in the extraction process and sample preconcentration, a solid-phase microextraction method was proposed by Pawliszyn and coworkers [156-158]. [Pg.103]

Ouyang, G., Y. Chen, and J. Pawliszyn. 2005. Time-weighted average water sampling with a solid-phase microextraction device. Anal. Chem. 77 7319-7325. [Pg.62]

Ouyang, G.F., W.N. Zhao, L. Bragg, Z.P. Qin, M. Alaee, and J. Pawliszyn. 2007. Time-weighted average water sampling in Lake Ontario with solid-phase microextraction passive samplers. Environ. Sci. Technol. 41 4026MO31. [Pg.62]

MEPS has so far been applied mainly to the analysis of drugs in biological samples only one application for the extraction of PAHs in water has been published.26 One of the major advantages of the MEPS design is that the packed syringe can be used many times over, for example, more than 400 times for water samples. Moreover, the technique permits a fast handling time in the analysis of PAHs in water, the speed enhancement being 15 and 100 times compared to the literature procedures of solid-phase microextraction (SPME) and stir bar sorptive extraction (SBSE), respectively see Sections 4.2.3 and 4.2.4. [Pg.73]

Stir bar sorptive extraction (SBSE), an approach theoretically similar to SPME, was recently introduced [141] for the trace enrichment of organic compounds from aqueous food, biological, and environmental samples. A stir bar is coated with a sorbent and immersed in the sample to extract the analyte from solution. To date, reported SBSE procedures were not usually operated as exhaustive extraction procedures however, SBSE has a greater capacity for quantitative extraction than SPME. The sample is typically stirred with the coated stir bar for a specified time, usually for less than 60 minutes, depending on the sample volume and the stirring speed, to approach equilibrium. SBSE improves on the low concentration capability of in-sample solid-phase microextraction (IS-SPME). [Pg.125]

Solid-phase microextraction (SPME) is a fast and solventless modification of SPE techniques [20]. SPME involves the use of fiber (fused silica fiber or polymer-coated fused fiber) coated by an adsorbent. The method is applied for extraction of different kinds of both volatile and nonvolatile analytes from different kinds of media, which can be in liquid or gas phase. In the direct extraction mode, coated fiber is immersed in the sample for a defined time, until equilibrium between the sample matrix and the solid phase is reached. The analyte is transported by diffusion directly to the extracting phase. In the next stage, the compound of interest... [Pg.128]

Headspace solid-phase microextraction (HS-SPME) is a rapid and solvent-free modification of the SPME technique in which a fine fused silica fiber with a polymeric coating is inserted into a headspace gas to extract organic compounds and directly transfer them into the injector of a gas chromatograph for thermal desorption and analysis. In this technique, the quantity of compounds extracted onto the fiber depends on the polarity and thickness of the stationary phase as well as on extraction time and concentration of volatiles in the sample. [Pg.130]

Calibration is carried out using standard calibration curves. The simplicity, repeatability, and low cost of the method have allowed its use for routine determination of trihalomethanes in tap water. SOME has also been compared with solid phase microextraction (SPME), purge and trap (P T), and direct aqueous injection (DAI) [10]. This technique offers accuracy comparable with that obtained using P T and DAI. With respect to conventional LEE, the SDME method is more accurate. In contrast to DAI and P T, it requires no special equipment. SDME has been used for extraction of chlorophenols [II], pesticides [12, 13], warfare agents [14], and butanone derivatives [15], and for control of food products [16]. The low costs of the SDME method (typical GC syringe and 2-3 pL of solvent), simplicity, and short extraction time (approximately 15 min) make it particularly suitable for preliminary analyses of organic pollutants in water samples. It can also be an effective alternative to SPME, as it does not require the use of expensive instrumentation. [Pg.407]

Sample preparation represents a formidable challenge in the chemical analysis of the real-world samples. Not only is the majority of total analysis time spent in sample preparation, but also it is the most error-prone, least glamorous, and the most labor-intensive task in the laboratory. The components to be separated from the matrix are usually taken up with an auxiliary substance such as a carrier gas, an organic solvent, or an adsorbent. These separation processes can be regarded as extraction procedures (i.e., liquid-liquid extraction, liquid-solid extraction, Soxhlet extraction, solid-phase extraction, supercritical fluid extraction, solid-phase microextraction, etc.). [Pg.1146]


See other pages where Solid-phase microextraction sampling time is mentioned: [Pg.402]    [Pg.102]    [Pg.124]    [Pg.129]    [Pg.431]    [Pg.432]    [Pg.438]    [Pg.264]    [Pg.65]    [Pg.42]    [Pg.102]    [Pg.169]    [Pg.547]    [Pg.547]    [Pg.1084]    [Pg.67]    [Pg.231]    [Pg.320]    [Pg.432]    [Pg.284]    [Pg.261]    [Pg.157]    [Pg.53]    [Pg.345]    [Pg.131]    [Pg.48]    [Pg.422]    [Pg.396]    [Pg.655]    [Pg.1147]   
See also in sourсe #XX -- [ Pg.79 ]