Limiting factor

Additional limiting factor is the unsharpness resulted fi om the X-ray source size, [6] The unsharpness (Ug), in terms of the source size (f)and geometrical magnification (M), is given... [Pg.477]

The linear relation between the PSL signal and neutron fluence was established to exist over three decades up to 6. lO cm. The IP-ND can be used as fast and efficient neutron monitors at rather low neutron fluxes. However, for neutron dosimetry individual IP-ND must be calibrated individually since their sensitiviy can differ from one plate to another. In Gd/film based direct NR the film fog below the exposure dose of about 8.10 cm is the limiting factor. [Pg.509]

The final velocity of these two ions will be the same, but their final flight times will differ by the above turnaround time, This results in a broadening of the TOF distributions for each ion mass, and is anotiier limiting factor when considering the mass (time) resolution of the instrument. [Pg.1353]

Typically, PIXE measurements are perfonned in a vacuum of around 10 Pa, although they can be perfonned in air with some limitations. Ion currents needed are typically a few nanoamperes and current is nonnally not a limiting factor in applying the teclmique with a particle accelerator. This beam current also nonnally leads to no significant damage to samples in the process of analysis, offering a non-destmctive analytical method sensitive to trace element concentration levels. [Pg.1843]

One of the major limiting factors for the time resolution of flow-hibe experiments is the time required for mixing reactants and—to a lesser extent—the resolution of distance. With typical fast flow rates of more than 25 ms [42, 43] the time resolution lies between milliseconds and microseconds. [Pg.2117]

Van Gunsteren, W.F., Beutler, T.C., Praternali, F., King, P.M., Mark, A.E., Smith, P.E. Computation of free energy in practice Choice of approximations and accuracy limiting factors, in Computer Simulations of Biomolecular Systems, Vol 2, W.F. van Gunsteren, P.K. Weiner and A.J. Wilkinson, eds. Escom, Leiden (1993) 315-348. [Pg.28]

Finally, values of sx are directly proportional to transmittance for indeterminate errors due to fluctuations in source intensity and for uncertainty in positioning the sample cell within the spectrometer. The latter is of particular importance since the optical properties of any sample cell are not uniform. As a result, repositioning the sample cell may lead to a change in the intensity of transmitted radiation. As shown by curve C in Figure 10.35, the effect of this source of indeterminate error is only important at low absorbances. This source of indeterminate errors is usually the limiting factor for high-quality UV/Vis spectrophotometers when the absorbance is relatively small. [Pg.411]

Accuracy The accuracy of a controlled-current coulometric method of analysis is determined by the current efficiency, the accuracy with which current and time can be measured, and the accuracy of the end point. With modern instrumentation the maximum measurement error for current is about +0.01%, and that for time is approximately +0.1%. The maximum end point error for a coulometric titration is at least as good as that for conventional titrations and is often better when using small quantities of reagents. Taken together, these measurement errors suggest that accuracies of 0.1-0.3% are feasible. The limiting factor in many analyses, therefore, is current efficiency. Fortunately current efficiencies of greater than 99.5% are obtained routinely and often exceed 99.9%. [Pg.507]

For given operating conditions and submergence, the dry cake production rate increases with the speed of rotation (eq. 10) and the limiting factor is usually the minimum cake thickness which can stiU be successfiiUy discharged by the method used in the filter. Equation 11 shows the dependence of the sohds yield on cake thickness ... [Pg.393]

In air conditioning (qv) of closed spaces, a wider latitude in design features can be exercised (23,24). Blowers are used to pass room or cabin air through arrays of granules or plates. Efficiencies usuaHy are 95% or better. The primary limiting factor is the decreased rate of absorption of carbon dioxide. However, an auxHiary smaH CO2 sorption canister can be used. Control of moisture entering the KO2 canister extends the life of the chemical and helps maintain the RQ at 0.82. [Pg.487]

The potential for normal brain tissue injury is one of the limiting factors in the use of XRT for brain tumors. Pentobarbital is a cerebral radioprotectant in rodent and primate models after single doses, but is associated with significant risks. Of alternative barbiturates, thiopental given to tats receiving 70-Gy (7000-rad) whole-brain irradiation in a single fraction enhances the 30-day survival similarly to pentobarbital, whereas ethohexital and phenobarbital show no radioprotective activity (250). [Pg.499]


See other pages where Limiting factor is mentioned: [Pg.271]    [Pg.774]    [Pg.1055]    [Pg.574]    [Pg.1235]    [Pg.1350]    [Pg.1460]    [Pg.2485]    [Pg.161]    [Pg.395]    [Pg.597]    [Pg.1183]    [Pg.123]    [Pg.508]    [Pg.237]    [Pg.29]    [Pg.322]    [Pg.325]    [Pg.486]    [Pg.181]    [Pg.212]    [Pg.56]    [Pg.278]    [Pg.32]    [Pg.231]    [Pg.265]    [Pg.474]    [Pg.351]    [Pg.165]    [Pg.401]    [Pg.122]    [Pg.184]    [Pg.338]    [Pg.466]    [Pg.82]    [Pg.191]    [Pg.54]    [Pg.481]    [Pg.499]    [Pg.20]   
See also in sourсe #XX -- [ Pg.455 ]

See also in sourсe #XX -- [ Pg.21 , Pg.22 ]

See also in sourсe #XX -- [ Pg.361 ]

See also in sourсe #XX -- [ Pg.137 ]