Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Solid phase extraction eluting

Water Solid phase extraction. Eluted with pentane, concentrated. GC/ECD 0.1 ppb 100 Russo et al. 1993... [Pg.145]

To overcome this problem, a radioimmunoassay method was developed (155) in which urine is enzymatically hydrolyzed to be subsequently purified by Ci8 solid-phase extraction. Elution was carried out using ethyl acetate, and the extract was analyzed by reversed-phase LC. The fraction containing the analyte was collected, evaporated, and submitted to radioimmunoassay. In this way, dexamethasone separated from natural corticosteroids and other synthetic corticosteroids that could cross-react in the assay. [Pg.863]

Solid-phase extraction, elution, evaporation, and formation of TMS-deriva-tives is the most frequently used pretreatment method for the determination of cocaine and its metabolites by GC-MS. A CFS for the automated pretreatment... [Pg.260]

A method which uses supercritical fluid/solid phase extraction/supercritical fluid chromatography (SE/SPE/SEC) has been developed for the analysis of trace constituents in complex matrices (67). By using this technique, extraction and clean-up are accomplished in one step using unmodified SC CO2. This step is monitored by a photodiode-array detector which allows fractionation. Eigure 10.14 shows a schematic representation of the SE/SPE/SEC set-up. This system allowed selective retention of the sample matrices while eluting and depositing the analytes of interest in the cryogenic trap. Application to the analysis of pesticides from lipid sample matrices have been reported. In this case, the lipids were completely separated from the pesticides. [Pg.241]

To determine secondary alkanesulfonates in sewage wastewaters, solid phase extraction (SPE) and a single-step procedure which combines elution and injection port derivatization for analysis with GC-MS were developed [36]. Again a tetrabutylammonium ion pair reagent was employed both to elute the secondary alkanesulfonates as their ion pairs from CI8-bonded silica disks and to derivatize sulfonate ion pairs under GC injection port conditions. Secondary alkanesulfonates were effectively recovered from samples of raw sewage (>92%) and from primary (>98%) and secondary (>85%) effluents. No... [Pg.170]

Residues of isoxaflutole, RPA 202248 and RPA 203328 are extracted from surface water or groundwater on to an RP-102 resin solid-phase extraction (SPE) cartridge, then eluted with an acetonitrile-methanol solvent mixture. Residues are determined by liquid chromatography/tandem mass spectrometry (LC/MS/MS) on a Cg column. Quantitation of results is based on a comparison of the ratio of analyte response to isotopically labeled internal standard response versus analyte response to internal standard response for calibration standards. [Pg.510]

Milbemectin consists of two active ingredients, M.A3 and M.A4. Milbemectin is extracted from plant materials and soils with methanol-water (7 3, v/v). After centrifugation, the extracts obtained are diluted to volume with the extraction solvent in a volumetric flask. Aliquots of the extracts are transferred on to a previously conditioned Cl8 solid-phase extraction (SPE) column. Milbemectin is eluted with methanol after washing the column with aqueous methanol. The eluate is evaporated to dryness and the residual milbemectin is converted to fluorescent anhydride derivatives after treatment with trifluoroacetic anhydride in 0.5 M triethylamine in benzene solution. The anhydride derivatives of M.A3 and M.A4 possess fluorescent sensitivity. The derivatized samples are dissolved in methanol and injected into a high-performance liquid chromatography (HPLC) system equipped with a fluorescence detector for quantitative determination. [Pg.1332]

Principles and Characteristics Solid-phase extraction (SPE) is a very popular sample preparation and clean-up technique. In SPE solutes are extracted from a liquid (or gaseous) phase into a solid phase. Substances that have been extracted by the solid particles can be removed by washing with an appropriate liquid eluent. Usually, the volume of solvent needed for complete elution of the analytes is much smaller (typically < 1 mL) than the original sample volume. A concentration of the analytes is thus achieved. [Pg.124]

Application of SPE to sample clean-up started in 1977 with the introduction of disposable cartridges packed with silica-based bonded phase sorbents. The solid phase extraction term was devised in 1982. The most commonly cited advantages of SPE over liquid-liquid extraction (LLE) as practiced on a macroscale include the reduced time and labor requirements, use of much lower volumes of solvents, minimal risk of emulsion formation, selectivity achievable when desired, wide choices of sorbents, and amenability to automation. The principle of operation consists of four steps (1) conditioning of the sorbent with a solvent and water or buffer, (2) loading of the sample in an aqueous or aqueous low organic medium, (3) washing away unwanted components with a suitable combination of solvents, and (4) elution of the desired compound with an appropriate organic solvent. [Pg.6]

Pankey et al.21 described a rapid, reliable, and specific enzyme multiplied immunoassay technique (EMIT ) for amitriptyline, nortriptyline, imipramine, and desipramine in sera. To overcome crossreactivity, solid phase extraction was included in sample pretreatment. Disposable 1 mL columns packed with covalently labeled silica gel were conditioned with HPLC-grade methanol (1 mL) and then with de-ionized or distilled water (1 mL). Serum (calibrator, control, or patient sample, 500 L) was applied onto the column, eluted to waste, washed with 900 /uL of wash solution containing acetonitrile (236.1 g/L) and ion-pairing reagent in acetate buffer, pH 4.2, washed with 500 fiL of mobile phase solution containing acetonitrile (393.5 g/L) in methanolic phosphate buffer, pH 7.0,... [Pg.301]

De la Torre, R. et al. 1998. Quantitative determination of tricyclic antidepressnts and their metabolites in plasma by solid phase extraction (bond-elut TCA) and separation by capillary gas chromatography with nitrogen-phosphorus detection. Ther Drug Monit. 20 340. [Pg.316]

Mills and Thurman [105] studied the mixed mode isolation of Triazine metabolites from soils using automated solid phase extraction with methanohwater (4 lu/u) extracts of the sample. Methanol is evaporated from the extract and the metabolites are collected on an octadecyl resin (Cl8) column. The analytes are eluted with ethyl acetate leaving the impurities on the C18 resin column. The detection limit of this method is 0-lgg kg 1-... [Pg.239]

In solid phase extraction, the liquid solution containing the analyte is passed through a cartridge containing a solid sorbent. The sorbent retains either the analyte or its matrix. If it is the analyte that is retained by the sorbent, the cartridge is first washed with a solvent that will sweep away interferences. The analyte is then eluted with a stronger solvent and collected. If it is the matrix that is retained by the sorbent, the analyte is eluted immediately and collected. [Pg.29]

Water Solid phase extraction with Empore disk. Eluted with ethyl acetate. Dried with sodium sulfate, concentrated. GC/ECD 4 ppt 86 Tomkins et al.1992... [Pg.145]

Solid phase extraction of milk mixed with 0.5% toluene. Eluted with hexane. [Pg.146]

In environmental analytical applications where analyte concentrations, e.g. surfactants or their metabolites, are quite low, extraction and concentration steps become essential. Solid phase extraction (SPE) with cartridges, disks or SPME fibres (solid phase micro extraction) because of its good variety of SP materials available has become the method of choice for the analysis of surfactants in water samples in combination with FIA as well as LC—MS analysis. SPE followed by sequential selective elution provides far-reaching pre-separations if eluents with different polarities and their mixtures are applied. The compounds under these conditions are separated in the MS spectrometer by their m/z ratios providing an overview of the ionisable compounds contained in a sample. Identification in the sense it has been mentioned before, however, requires the generation of fragments. [Pg.156]

Other techniques to improve throughput are instrumentation based and may involve multiple HPLC systems. The simplest method involves the automated use of solid phase extraction cartridges for sample cleanup followed by direct injection into the mass spectrometer [114], Coupling of multiple HPLC systems to one mass spectrometer allows one column to equilibrate and separate while another column to flow into the mass spectrometer. Multiple HPLC systems may be configured such that the mass spectrometer is only exposed to each serial HPLC eluent as the analyte of interest is eluted [115,116]. Although multiple H P LC-based methods may increase throughput, they also typically decrease sensitivity and may confound data workup and interpretation. [Pg.205]


See other pages where Solid phase extraction eluting is mentioned: [Pg.234]    [Pg.234]    [Pg.213]    [Pg.589]    [Pg.589]    [Pg.241]    [Pg.378]    [Pg.31]    [Pg.265]    [Pg.427]    [Pg.123]    [Pg.508]    [Pg.426]    [Pg.591]    [Pg.773]    [Pg.716]    [Pg.905]    [Pg.430]    [Pg.137]    [Pg.61]    [Pg.333]    [Pg.216]    [Pg.193]    [Pg.356]    [Pg.173]    [Pg.10]    [Pg.10]    [Pg.22]    [Pg.121]    [Pg.227]    [Pg.28]    [Pg.92]    [Pg.110]    [Pg.196]    [Pg.225]   
See also in sourсe #XX -- [ Pg.258 ]




SEARCH



Extract phase

Molecularly imprinted solid phase extraction with pulsed elution

Phase extraction

Solid phase extraction elution pattern

Solid-phase extraction elution

© 2024 chempedia.info