Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Size-a test

When screening experiments are used, it is generally anticipated that several effects may be nonzero. Hence, one ought to use statistical procedures that are known to provide strong control of error rates. It is not enough to control error rates only under the complete null distribution. This section discusses exact confidence intervals. Size-a tests are considered in Section 5. [Pg.276]

To develop the test, we use the closed testing procedure of Marcus et al. (1976). This procedure requires the construction of a size-a test of the hypothesis... [Pg.281]

Let ci denote the upper-a quantile of the distribution of 7 when all It effects are zero. Then, the test that rejects 77o,/ if 7) > c/ is a size-a test of the null hypothesis because the test statistic 7) is a nonincreasing function of Pi for each K I (Voss and Wang, 2005). For each i, the closed testing procedure rejects 770jl Pi = 0 if and only if H0j is rejected for each 7 containing i. Use of this procedure controls the simultaneous error rate to be at most a see Marcus et al. (1976). It requires the... [Pg.281]

Use of a correction factor may be useful as well, especially with smaller sample sizes. A test statistic that makes use of the correction factor is ... [Pg.133]

If the maximum likelihood estimates of the full and reduced models are normally distributed then for large n, — 2Ln( ) is distributed as a chi-squared random variable with f-r degrees of freedom. An approximate size a test then is to declare the full model the superior model if... [Pg.23]

At lower temperatures, the crystals increase in size, and form networks that trap the liquid and hinder its ability to flow. The pour point is attained which can, depending on the diesel fuel, vary between -15 and -30°C. This characteristic (NF T 60-105) is determined, like the cloud point, with a very rudimentary device (maintaining a test tube in the horizontal position without apparent movement of the diesel fuel inside). [Pg.215]

This paper deals with the control of weld depth penetration for cylinders in gold-nickel alloy and tantalum. After introducing the experimental set-up and the samples description, the study and the optimization of the testing are presented for single-sided measurements either in a pulse-echo configuration or when the pump and the probe laser beams are shifted (influence of a thermal phenomenon), and for different kind of laser impact (a line or a circular spot). First, the ultrasonic system is used to detect and to size a flat bottom hole in an aluminium plate. Indeed, when the width of the hole is reduced, its shape is nearly similar to the one of a slot. Then, the optimization is accomplished for... [Pg.693]

Proceed as follows for both solid and liquid compounds. By means of a test-tube holder, hold the tube in a horizontal position, and by means of a small flame gently heat the mixture at the open end. Increase the size of the flame gradually until the mixture is red-hot at this end. Now slowly and cautiously extend the heating towards the closed end until the whole of the mixture is red-hot. (If during the extension of the heating, the mixture tends to be pushed out of the tube by the evolution of gas, stop the heating momentarily, and rotate the... [Pg.326]

It is necessary to estabUsh a criterion for microbial death when considering a sterilization process. With respect to the individual cell, the irreversible cessation of all vital functions such as growth, reproduction, and in the case of vimses, inabiUty to attach and infect, is a most suitable criterion. On a practical level, it is necessary to estabUsh test criteria that permit a conclusion without having to observe individual microbial cells. The failure to reproduce in a suitable medium after incubation at optimum conditions for some acceptable time period is traditionally accepted as satisfactory proof of microbial death and, consequentiy, stetihty. The appHcation of such a testing method is, for practical purposes, however, not considered possible. The cultured article caimot be retrieved for subsequent use and the size of many items totally precludes practical culturing techniques. In order to design acceptable test procedures, the kinetics and thermodynamics of the sterilization process must be understood. [Pg.404]

A number of manufacturers started commercial production of nickel—MH cells in 1991 (31—35). The initial products are "AA"-size, "Sub-C", and "C -size cells constmcted in a fashion similar to small sealed nickel —cadmium cells. Table 6 compares the Ovonics experimental cell and a similar sized nickel—cadmium cell. Ovonics also deUvered experimental electric vehicle cells, 22 A-h size, for testing. The charge—discharge of "AA" cells produced in Japan (Matsushita) are compared in Figure 22. [Pg.562]

Freeze Crystallization. Freezing may be used to form pure ice crystals, which are then removed from the slurry by screens sized to pass the fine sohds but to catch the crystals and leave behind a more concentrated slurry. The process has been considered mostly for solutions, not suspensions. However, freeze crystallization has been tested for concentrating orange juice where sohds are present (see Fruit juices). Commercial apphcations include fmit juices, coffee, beer, wine (qv), and vinegar (qv). A test on milk was begun in 1989 (123). Freeze crystallization has concentrated pulp and paper black hquor from 6% to 30% dissolved sohds and showed energy savings of over 75% compared with multiple-effect evaporation. Only 35—46 kJ/kg (15—20 Btu/lb) of water removed was consumed in the process (124). [Pg.25]

Detention efficiency. Conversion from the ideal basin sized by detention-time procedures to an actual clarifier requires the inclusion of an efficiency factor to account for the effects of turbulence and nonuniform flow. Efficiencies vaiy greatly, being dependent not only on the relative dimensions of the clarifier and the means of feeding but also on the characteristics of the particles. The cui ve shown in Fig. 18-83 can be used to scale up laboratoiy data in sizing circular clarifiers. The static detention time determined from a test to produce a specific effluent sohds concentration is divided by the efficiency (expressed as a fraction) to determine the nominal detention time, which represents the volume of the clarifier above the settled pulp interface divided by the overflow rate. Different diameter-depth combinations are considered by using the corresponding efficiency factor. In most cases, area may be determined by factors other than the bulksettling rate, such as practical tank-depth limitations. [Pg.1679]

Typical separation efficiency curves of an air classifier versus particle size are given in Fig. 20-14. The amount of top size in the fines may be very low, but there is typically 10 to 30 percent fines in the coarse product that is, the low end of the cui ve tends to flatten out at 10 to 30 percent. In addition, the separation at the cut size is typically a gradu cui ve. Data of this sort, which are needed to evaluate closed-circuit mill performance, are seldom available. See subsection on characteristics of size classifiers for a testing method. [Pg.1857]

Based upon the above-mentioned species interactions, pilot-scale testing is generally recommended to accurately size a biofilter bed for a multicomponent waste gas stream. [Pg.2193]

For example, the deterministic value for the yield strength, Sy, for SAE 1018 cold drawn steel for the size range tested is approximately 395 MPa (Green, 1992). Table 4.6 gives the mean and standard deviation as A(540,41) MPa. The lower bound value as used in deterministic design becomes ... [Pg.157]

The vent sizing package (VSP) was developed by Fauskes Associates, Inc. The VSP and its latest version VSP2 employ the low thermal mass test cell stainless steel 304 and Hastelloy test cell with a volume of 120 ml contained in a 4-1, high-pressure vessel as shown in Figure 12-13. The typical ([t-factor is 1.05-1.08 for a test cell wall thickness of 0.127-0.178 mm. Measurements consist of sample temperature Tj and pressure Pj, and external guard temperature Tj and... [Pg.934]


See other pages where Size-a test is mentioned: [Pg.273]    [Pg.276]    [Pg.280]    [Pg.24]    [Pg.90]    [Pg.273]    [Pg.276]    [Pg.280]    [Pg.24]    [Pg.90]    [Pg.450]    [Pg.882]    [Pg.2268]    [Pg.41]    [Pg.168]    [Pg.190]    [Pg.390]    [Pg.111]    [Pg.390]    [Pg.405]    [Pg.205]    [Pg.225]    [Pg.189]    [Pg.1398]    [Pg.1757]    [Pg.444]    [Pg.147]    [Pg.455]    [Pg.154]    [Pg.263]    [Pg.61]    [Pg.168]    [Pg.168]    [Pg.168]    [Pg.528]    [Pg.67]    [Pg.124]    [Pg.362]    [Pg.433]   
See also in sourсe #XX -- [ Pg.273 , Pg.276 ]




SEARCH



© 2024 chempedia.info