Vent sizing package

Vent Sizing Package (VSP) The VSP is an extension of ARC technology. The VSP is a bench-scale apparatus for characterizing runaway chemical reactions. It makes possible the sizing of pressure relief systems with less engineering expertise than is required with the ARC or other methods. [Pg.2312]

The vent sizing package (VSP) was developed by Fauskes Associates, Inc. The VSP and its latest version VSP2 employ the low thermal mass test cell stainless steel 304 and Hastelloy test cell with a volume of 120 ml contained in a 4-1, high-pressure vessel as shown in Figure 12-13. The typical ([t-factor is 1.05-1.08 for a test cell wall thickness of 0.127-0.178 mm. Measurements consist of sample temperature Tj and pressure Pj, and external guard temperature Tj and... [Pg.934]

Figure 12-13. Vent sizing package (VSP) apparatus. (Source Fauskes Associates Inc.)... Figure 12-13. Vent sizing package (VSP) apparatus. (Source Fauskes Associates Inc.)...
Fauske and Associates, Inc., Vent Sizing Package System Manual Methodology and General Operations, FAI/88-41, February 1988. [Pg.546]

Leung, J. C., Creed, M. J. and Fisher, H. G., Round-Robin Vent Sizing Package Results, Proceedings of the International Symposium on Runaway Reactions, CCPS, Cambridge, MA, March 1989. [Pg.546]

Several commercial calorimeters are available to characterize runaway reactions. These include the accelerating rate calorimeter (ARC), the reactive system screening tool (RSST), the automatic pressure-tracking adiabatic calorimeter (APTAC), and the vent sizing package (VSP). Each calorimeter has a different sample size, container design, data acquisition hardware, and data sensitivity. [Pg.366]

Figure 8-9 Runaway reaction temperature data acquired using the vent sizing package (VSP). Figure 8-9 Runaway reaction temperature data acquired using the vent sizing package (VSP).
When a runaway reaction occurs within a reactor vessel, two-phase flow should be expected during the relief process. The vent sizing package (VSP) laboratory apparatus described in chapter 8 provides the much needed temperature and pressure rise data for relief area sizing. [Pg.395]

ARC = Accelerating Rate Calorimeter (Columbia Scientific Instrument Corp.) DSC = Differential Scanning Calorimeter DTA = Differential Thermal Analysis RC1 = Reactor Calorimeter (Mettler-Toledo Inc.) RSST = Reactive System Screening Tool (Fauske and Associates) VSP = Vent Size Package (Fauske and Associates) ... [Pg.6]

Experimental data can be obtained from the DSC and from reaction calorimeters for the conditions of the desired reactions, and from the DSC, the ARC, the Reactive System Screening Test (RSST—Fauske and Associates) and from the Vent Size Package (VSP) for conditions allowing undesired reactions. The pressure effect can be studied using the ARC or DIERS methods. From the results of these tests, the rate of temperature rise and the maximum acceptable conditions for specific equipment can be calculated. The same holds for the pressure rise rate. [Pg.93]

The original Vent Size Package (VSP) became available first in the United States, and is currently distributed by Fauske and Associates. A very similar type of equipment, called PHI-TEC, is available in Europe. [Pg.124]

FIGURE 3.15. Vent Size Package (VSP) Test Cell. [Pg.125]

The Reactive System Screening Tool (RSST) was described in Section 33.2.7. This apparatus is a relatively recent development. Therefore, only limited literature data are available regarding the application of results from this equipment for direct scale-up of reactor systems. The Vent Size Package (VSP) is discussed further in Section 3.3.2.6. [Pg.137]

The Vent Size Package (VSP) apparatus was described in Section 3.3.2.6. The relatively small 100-cm3 test cell size implies that the samples tested may not be fully representative of commercial scale systems in some cases. The contents of the test vessel may be stirred, although the stirring facilities are not... [Pg.145]

Testing includes screening (e.g., literature research, mixing calorimetiy, thermodynamic calculations, estimation of heats of reaction, DSC, flash point calculations), quantitative assessment (e g., accelerated rate calorimetry, specialized calorimetry), and scaleup (vent size packaging [VSP], modeling, reaction calorimetry). [Pg.383]

Vent Sizing Package". A type of adiabatic calorimeter. See A2.2.2. [Pg.230]


See other pages where Vent sizing package is mentioned: [Pg.181]    [Pg.185]    [Pg.233]    [Pg.934]    [Pg.934]    [Pg.124]    [Pg.428]    [Pg.117]    [Pg.124]    [Pg.145]    [Pg.30]    [Pg.78]    [Pg.9]    [Pg.9]    [Pg.100]    [Pg.270]    [Pg.128]    [Pg.97]    [Pg.90]    [Pg.233]   
See also in sourсe #XX -- [ Pg.934 , Pg.935 ]

See also in sourсe #XX -- [ Pg.934 , Pg.935 ]

See also in sourсe #XX -- [ Pg.43 ]




SEARCH



Scale-up of Vent Size Package (VSP) Results

Vent Size Package

Vent Size Package

Vent Size Package (VSP)

Vent Size Package described

Vent Size Package results

Vent sizing

Vent sizing package (VSP

Venting

Vents

Vents vent sizing package

Vents vent sizing package