There are two procedures for doing this. The first makes use of a metal probe coated with an emitter such as polonium or Am (around 1 mCi) and placed above the surface. The resulting air ionization makes the gap between the probe and the liquid sufficiently conducting that the potential difference can be measured by means of a high-impedance dc voltmeter that serves as a null indicator in a standard potentiometer circuit. A submerged reference electrode may be a silver-silver chloride electrode. One generally compares the potential of the film-covered surface with that of the film-free one [83, 84]. [Pg.116]

Birss V I and Smith C K 1987 The anodic behaviour of silver in chloride solutions-l. The formation and reduction of thin silver chloride films Electrochim. Acta 32 259-68... [Pg.2756]

Addition of silver nitrate to a solution of a chloride in dilute nitric acid gives a white precipitate of silver chloride, AgCl, soluble in ammonia solution. This test may be used for gravimetric or volumetric estimation of chloride the silver chloride can be filtered off, dried and weighed, or the chloride titrated with standard silver nitrate using potassium chromate(VI) or fluorescein as indicator. [Pg.348]

Addition of silver nitrate to a solution of a bromide in nitric acid produces a cream-coloured precipitate of silver bromide, soluble in ammonia (but not so readily as silver chloride). The reaction may be used quantitatively, as for a chloride. [Pg.349]

A compound of cobalt has the formula Co(NH3)jtCl. 0.500 g of it was dissolved in 50.00 cm M hydrochloric acid the excess acid required 40.00 cm M sodium hydroxide solution to neutralise it. Another 0.500 g portion of the compound was dissolved in water and allowed to react with excess silver nitrate solution. 0.575 g of silver chloride was precipitated. [Pg.422]

Silver chloride is readily soluble in ammonia, the bromide less readily and the iodide only slightly, forming the complex cation [Ag(NH3)2]. These halides also dissolve in potassium cyanide, forming the linear complex anion [AglCN) ] and in sodium thiosulphate forming another complex anion, [Ag(S203)2] ... [Pg.428]

All the silver halides are sensitive to light, decomposing eventually to silver. In sunlight, silver chloride turns first violet and finally black. The use of these compounds in photography depends on this (see below). (All silver salts are, in fact, photosensitive—the neck of a silver nitrate bottle is black owing to a deposit of silver.)... [Pg.428]

Silver chloride is reduced to the metal by zinc. One of the methods of recovering silver from silver residues depends on this. The residue is first treated with concentrated hydrochloric acid and then sulphuric acid and zinc added ... [Pg.428]

It was known in the sixteenth century that silver salts were photosensitive, but it was not until the beginning of the nineteenth century, when Herschel found that silver chloride was soluble in sodium thiosulphate, that photography became possible. [Pg.428]

The fixed plate is now a negative , for those patches on which most light fell are black. The process is reversed in printing to make the positive —the printing paper having a covering of silver chloride or bromide or a mixture of the two. This, in turn, is developed and fixed as was the plate or film. [Pg.428]

Add a few drops of the distillate to an aqueous silver nitrate solution containing some dilute nitric acid and warm gently no silver chloride should be precipitated, indicating the complete absence of unchanged acetyl chloride. [Pg.116]

To determine which halogen is present, take 1-2 ml. of the filtrate from the sodium fusion, and add dilute sulphuric acid until just acid to litmus. Add about 1 ml. of benzene and then about 1 ml. of chlorine water and shake. A yellowish-brown colour in the benzene indicates bromine, and a violet colour iodine. If neither colour appears, the halogen is chlorine. The result may be confirmed by testing the solubility of the silver halide (free from cyanide) in dilute ammonia solution silver chloride is readily soluble, whereas the bromide dissolves with difficulty, and the iodide not at all. [Pg.325]

Acid chlorides (but not acid anhydrides) precipitate silver chloride on treatment with aqueous AgNOg acidified with HNO3-... [Pg.364]

Add a known volume ofo oaM.AgNOj solution (in excess) and boil the solution until the silver chloride has coagulated. Filter through a conical 5 cm. funnel, ensuring that the filter-paper does not protrude above the r m of the funnel. Wash the silver chloride and the filter-paper several times with a fine jet of distilled water. To the united filtrate and washings add i ml. of saturated ferric alum solution. The solution should be almost colourless if it is more than faintly coloured, add a few drops of concentrated nitric acid. Then titrate with 0 02M-ammonium thiocyanate solution until the permanent colour of ferric thiocyanate is just perceptible. (Alternatively the chloride may be determined potentiometrically.)... [Pg.507]

From the theory of the electrochemical cell, the potential in volts of a silver-silver chloride-hydrogen cell is related to the molarity m of HCI by the equation... [Pg.67]

Figure 3-1 Voltage Measurements on a Silver-Silver Chloride, Hydrogen Cell at 298.15 K. The contribution of the Standard Hydrogen Electrode is taken as zero by convention. Figure 3-1 Voltage Measurements on a Silver-Silver Chloride, Hydrogen Cell at 298.15 K. The contribution of the Standard Hydrogen Electrode is taken as zero by convention.
The two estimates for the first or a parameter of the parabolic fit are the intercepts on the voltage axis of Eig. 3-1, so both procedures arrive at a standard potential of the silver-silver chloride half-cell of 0.2225 V. The accepted modem value is 0.2223 V (Barrow, 1996). [Pg.68]

Silver chloride Aqueous ammonia or sodium thiosulfate. [Pg.1146]

Silvcr/Silvcr Chloride Electrodes Another common reference electrode is the silver/silver chloride electrode, which is based on the redox couple between AgCl and Ag. [Pg.473]

When the potential of an electrode of the first kind responds to the potential of another ion that is in equilibrium with M"+, it is called an electrode of the second kind. Two common electrodes of the second kind are the calomel and silver/silver chloride reference electrodes. Electrodes of the second kind also can be based on complexation reactions. Eor example, an electrode for EDTA is constructed by coupling a Hg +/Hg electrode of the first kind to EDTA by taking advantage of its formation of a stable complex with Hg +. [Pg.475]

The attenuated total reflectance (ATR) technique is used commonly in the near-infrared for obtaining absorption spectra of thin Aims and opaque materials. The sample, of refractive index i, is placed in direct contact with a material which is transparent in the region of interest, such as thallium bromide/thallium iodide (known as KRS-5), silver chloride or germanium, of relatively high refractive index so that Then, as Figure 3.f8... [Pg.64]

Silver bromoiodide Silver bronze alloys Silver-cadmium alloys Silver-cadmium cell Silver cell Silver chloride... [Pg.891]

Bronze disease necessitates immediate action to halt the process and remove the cause. For a long time, stabilization was sought by removal of the cuprous chloride by immersing the object in a solution of sodium sesquicarbonate. This process was, however, extremely time-consuming, frequentiy unsuccesshil, and often the cause of unpleasant discolorations of the patina. Objects affected by bronze disease are mostiy treated by immersion in, or surface appHcation of, 1 H-henzotriazole [95-14-7] C H N, a corrosion inhibitor for copper. A localized treatment is the excavation of cuprous chloride from the affected area until bare metal is obtained, followed by appHcation of moist, freshly precipitated silver oxide which serves to stabilize the chloride by formation of silver chloride. Subsequent storage in very dry conditions is generally recommended to prevent recurrence. [Pg.425]

Reference Electrodes and Liquid Junctions. The electrical cincuit of the pH ceU is completed through a salt bridge that usually consists of a concentrated solution of potassium chloride [7447-40-7]. The solution makes contact at one end with the test solution and at the other with a reference electrode of constant potential. The Hquid junction is formed at the area of contact between the salt bridge and the test solution. The mercury—mercurous chloride electrode, the calomel electrode, provides a highly reproducible potential in the potassium chloride bridge solution and is the most widely used reference electrode. However, mercurous chloride is converted readily into mercuric ion and mercury when in contact with concentrated potassium chloride solutions above 80°C. This disproportionation reaction causes an unstable potential with calomel electrodes. Therefore, the silver—silver chloride electrode and the thallium amalgam—thallous chloride electrode often are preferred for measurements above 80°C. However, because silver chloride is relatively soluble in concentrated solutions of potassium chloride, the solution in the electrode chamber must be saturated with silver chloride. [Pg.466]

Miscellaneous. Electron beams can be used to decompose a gas such as silver chloride and simultaneously deposit silver metal. An older technique is the thermal decomposition of volatile and extremely toxic gases such as nickel carbonyl [13463-39-3] Ni(CO)4, to form dense deposits or dendritic coatings by modification of coating parameters. [Pg.137]


See other pages where Silver chlorid is mentioned: [Pg.360]    [Pg.360]    [Pg.414]    [Pg.439]    [Pg.422]    [Pg.423]    [Pg.505]    [Pg.67]    [Pg.65]    [Pg.273]    [Pg.297]    [Pg.756]    [Pg.906]    [Pg.532]    [Pg.587]    [Pg.891]    [Pg.893]    [Pg.893]    [Pg.466]    [Pg.47]    [Pg.440]    [Pg.443]    [Pg.446]   