Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sample processing and analysis

As stated earlier the procedure for this analysis is based largely on the methods developed by Hangartner.(4) Figure 1 outlines the scheme utilised for sample processing and analysis. In addition to the detection system already discussed the only other significant difference in this work is the choice of adsorbent which is Carbotrap D-l a graphitised carbon black (GCB). The use of GCB s in environmental analysis is well documented in the literature both as column materials and adsorbants. (7, 8) Initial work within Severn Trent confirmed the claimed superiority of GCB s compared with adsorbents based on porous polymers such as Tenax GC. No evaluation of the relative merits of GCB s and activated carbons have been made at this laboratory but tests with the latter are likely in the future. [Pg.327]

Fig. 17 Detection of B. anthracis from murine blood, (a) Detector responses during all three stages of sample processing and analysis are portrayed in terms of total analysis time. The SPE trace (green) was taken from off-line DNA extraction of the same murine sample and is representative of the total DNA concentration observed in a typical extraction. The temperature (blue) and fluorescence intensity (black) represent on-line data, with a total analysis time <24 min. Three sequential injections and separations were carried out to ensure the presence of amplified product, (b) Fluorescence data from an integrated analysis of a blank sample (no DNA) control with marker peaks labeled. The inset represents valve actuation during co-injection, with the PR and MR pumping inlets indicated by the arrows, (c) Zoomed view of the first separation shown in (a), with the product peak marked. The second and third runs are overlaid with the time axis cropped. Inset shows the sizing curve of inverse migration time vs. logfbase pairs) with both the sizing standard peaks (open diamonds) and product (square) plotted for all three runs shown in (a). From these data, the product was 211 2 bp. Reproduced from [10] with permission... Fig. 17 Detection of B. anthracis from murine blood, (a) Detector responses during all three stages of sample processing and analysis are portrayed in terms of total analysis time. The SPE trace (green) was taken from off-line DNA extraction of the same murine sample and is representative of the total DNA concentration observed in a typical extraction. The temperature (blue) and fluorescence intensity (black) represent on-line data, with a total analysis time <24 min. Three sequential injections and separations were carried out to ensure the presence of amplified product, (b) Fluorescence data from an integrated analysis of a blank sample (no DNA) control with marker peaks labeled. The inset represents valve actuation during co-injection, with the PR and MR pumping inlets indicated by the arrows, (c) Zoomed view of the first separation shown in (a), with the product peak marked. The second and third runs are overlaid with the time axis cropped. Inset shows the sizing curve of inverse migration time vs. logfbase pairs) with both the sizing standard peaks (open diamonds) and product (square) plotted for all three runs shown in (a). From these data, the product was 211 2 bp. Reproduced from [10] with permission...
There are a number of other elements appearing from time to time in the laboratory. From these, chromium and nickel are most common. Both appear in enhanced concentrations in workers exposed to welding fumes, in galvanization processes, and in processing of ores. Prolonged exposure to Cr and/or Ni causes cancer and affects the kidney. Preferred methods of determination of Ni and Cr in urine are GF-AAS. Because of the risk of contamination of the very low concentrations in urine, extreme precautions in sample handling and analysis must be carried out. [Pg.206]

In this article, sampling methods for sediments of both paddy field and adjacent water bodies, and also for water from paddy surface and drainage sources, streams, and other bodies, are described. Proper sample processing, residue analysis, and mathematical models of dissipation patterns are also overviewed. [Pg.893]

In the following section, we explain the basic protocols used for removing the second-order quadrupolar broadening based on the refocusing of the second-order quadrupolar interaction. These protocols rely on mechanical reorientation of the rotor axis (DAS) or use a combination of sample spinning and rf manipulation of the spins evolution (MQMAS and STMAS). Experimental aspects of these methods, as well as methods for data processing and analysis, are described in Sects. 5.3 and 5.4. [Pg.144]

The application of technology in laboratories via automation and robotics (flexible automation) minimizes the need for human intervention in analytical processes, increases productivity, improves data quality, reduces costs, and enables experimentation that otherwise would be impossible. Pharmaceutical companies continuously look for ways to reduce the time and effort required for testing. To meet the ever-increasing demands for efficiency while providing consistent quality of analysis, more pharmaceutical R D and QC laboratories have now automated their sampling, sample preparation, and analysis procedures. [Pg.269]

CF-IRMS provides reliable data on micromoles or even nanomoles of sample without the need for cryogenic concentration because more of the sample enters the ion source than in DI-IRMS. CF-IRMS instruments accept solid, liquid, or gaseous samples such as leaves, soil, algae, or soil gas, and process 100-125 samples per day. Automated sample preparation and analysis takes 3-10 min per sample. The performance of CF-IRMS systems is largely determined by the sample preparation technology. A variety of inlet and preparation systems is available, including GC combustion (GC/C), elemental analyzer, trace gas pre-concentrator and other. The novel... [Pg.166]

This type of QC blank consists of a batch or subset of individual SPMDs of the same size and material as those prepared for a specific project. After preparation, SPMD-fabrication blanks are maintained frozen in vapor-tight metal cans under argon at -10 to -20 °C in the laboratory until the analysis of the project SPMDs. Processing and analysis of these blanks is concurrent with and identical to that of environmentally exposed SPMDs. The primary purpose of this type of QC sample is to account for any background contribution due to interferences from SPMD components, and for contamination incurred during laboratory storage, processing, and analytical procedures. [Pg.104]

When environmental conditions at an exposure site differ from those used for laboratory calibrations or when calibration data for an analyte are not available, at least one SPMD per site is spiked with PRCs. The type of compounds used for PRCs and their spiking levels were discussed earlier. PRC samples and standard SPMD samples (i.e., field-deployed SPMDs) differ only by the presence of the PRCs. Handling, processing and analysis are also identical. As implied above, the purpose of the PRC sample is to provide data for estimation of in situ sampling rates of target compounds. [Pg.106]

CE instrumentation is quite simple (see Chapter 3). A core instrument utilizes a high-voltage power supply (capable of voltages in excess of 30,000 V), capillaries (approximately 25—lOOpm I.D.), buffers to complete the circuit (e.g., citrate, phosphate, or acetate), and a detector (e.g., UV-visible). CE provides simplicity of method development, reliability, speed, and versatility. It is a valuable technique because it can separate compounds that have traditionally been difficult to handle by HPLC. Furthermore, it can be automated for quantitative analysis. CE can play an important role in process analytical technology (PAT). For example, an on-line CE system can completely automate the sampling, sample preparation, and analysis of proteins or other species that can be separated by CE. [Pg.3]

Natural products, from plants and foods to rocks and minerals, are complicated systems, but their analysis by Raman spectroscopy is a growing area. Most examples come from quality control laboratories, motivated to replace current time-consuming sample preparation and analysis steps with a less labor-intensive, faster technique but most authors anticipated the eventual application to process control. Often a method will be practiced in a trading house or customs facility to distinguish between items perceived to be of different qualities, and thus prices. [Pg.220]

The range of cell types that must be prepared, cultured and manufactured on a just in time basis, the number of detection systems that must be accommodated, the complex scheduling of incubation periods, sample preparation and analysis procedures, the form and fashion of data and post-analytical processing all contribute to a very complex laboratory, balancing a complicated set of demands. [Pg.13]

For these reasons, chromatography in its many forms has been the most widely used tool in both sample processing and measurement for trace organic analysis. Of the various chromatographic techniques, gas chromatography (GC) has been the method of unquestioned widest use for final measurement. This fact clearly recognizes that gas chromatographic techniques presently provide... [Pg.368]


See other pages where Sample processing and analysis is mentioned: [Pg.872]    [Pg.888]    [Pg.991]    [Pg.106]    [Pg.297]    [Pg.1153]    [Pg.1224]    [Pg.141]    [Pg.262]    [Pg.278]    [Pg.872]    [Pg.888]    [Pg.991]    [Pg.106]    [Pg.297]    [Pg.1153]    [Pg.1224]    [Pg.141]    [Pg.262]    [Pg.278]    [Pg.499]    [Pg.852]    [Pg.952]    [Pg.885]    [Pg.253]    [Pg.435]    [Pg.451]    [Pg.398]    [Pg.270]    [Pg.321]    [Pg.231]    [Pg.60]    [Pg.251]    [Pg.251]    [Pg.39]    [Pg.113]    [Pg.84]    [Pg.889]    [Pg.128]    [Pg.114]    [Pg.339]    [Pg.515]    [Pg.562]    [Pg.82]    [Pg.196]   


SEARCH



Process Sample

Process analysis

Process analysis processes

Process sampling

Processing analysis

Sample processing

Sampling and Sample Analysis

© 2024 chempedia.info