Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sample preparation sensitivity

A major advantage of this hydride approach lies in the separation of the remaining elements of the analyte solution from the element to be determined. Because the volatile hydrides are swept out of the analyte solution, the latter can be simply diverted to waste and not sent through the plasma flame Itself. Consequently potential interference from. sample-preparation constituents and by-products is reduced to very low levels. For example, a major interference for arsenic analysis arises from ions ArCE having m/z 75,77, which have the same integral m/z value as that of As+ ions themselves. Thus, any chlorides in the analyte solution (for example, from sea water) could produce serious interference in the accurate analysis of arsenic. The option of diverting the used analyte solution away from the plasma flame facilitates accurate, sensitive analysis of isotope concentrations. Inlet systems for generation of volatile hydrides can operate continuously or batchwise. [Pg.99]

Determination of gold concentrations to ca 1 ppm in solution via atomic absorption spectrophotometry (62) has become an increasingly popular technique because it is available in most modem analytical laboratories and because it obviates extensive sample preparation. A more sensitive method for gold analysis is neutron activation, which permits accurate determination to levels < 1 ppb (63). The sensitivity arises from the high neutron-capture cross section (9.9 x 10 = 99 barns) of the only natural isotope, Au. The resulting isotope, Au, decays by P and y emission with a half-life of 2.7 d. [Pg.381]

Gold is a useflil caUbration standard for this method (see Radioactive tracers). Whereas similar sensitivities can be achieved by inductively coupled plasma mass spectrometry (qv), the latter requires more extensive sample preparation to overcome interference by other metals such as copper (64). [Pg.381]

Glass-Transition Temperature. The T of PVP is sensitive to residual moisture (75) and unreacted monomer. It is even sensitive to how the polymer was prepared, suggesting that MWD, branching, and cross-linking may play a part (76). Polymers presumably with the same molecular weight prepared by bulk polymerization exhibit lower T s compared to samples prepared by aqueous solution polymerization, lending credence to an example, in this case, of branching caused by chain-transfer to monomer. [Pg.528]

The very low Hg concentration levels in ice core of remote glaciers require an ultra-sensitive analytical technique as well as a contamination-free sample preparation methodology. The potential of two analytical techniques for Hg determination - cold vapour inductively coupled plasma mass spectrometry (CV ICP-SFMS) and atomic fluorescence spectrometry (AFS) with gold amalgamation was studied. [Pg.171]

Most of the transition elements that are of primary interest in the semiconductor industry such as Fe, Cr, Mn, Co, and Ni, can be analyzed with very low detection limits. Second to its sensitivity, the most important advantage of NAA is the minimal sample preparation that is required, eliminating the likelihood of contamination due to handling. Quantitative values can be obtained and a precision of 1-5% relative is regularly achieved. Since the technique measures many elements simultaneously, NAA is used to scan for impurities conveniently. [Pg.672]

Recent developments in Raman equipment has led to a considerable increase in sensitivity. This has enabled the monitoring of reactions of organic monolayers on glassy carbon [4.292] and diamond surfaces and analysis of the structure of Lang-muir-Blodgett monolayers without any enhancement effects. Although this unenhanced surface-Raman spectroscopy is expected to be applicable to a variety of technically or scientifically important surfaces and interfaces, it nevertheless requires careful optimization of the apparatus, data treatment, and sample preparation. [Pg.260]

Elimination of sample preparation and handling of toxic solvents such as carbon disulphide Absence of solvent simplifies chromatograph Increased sensitivity Sample tubes can be reused ... [Pg.321]

The main advantages of electrothermal atomisers are that (a) very small samples (as low as 0.5 pL) can be analysed (b) often very little or no sample preparation is needed, in fact certain solid samples can be analysed without prior dissolution (c) there is enhanced sensitivity, particularly with elements with a short-wavelength resonance line in practice there is an improvement of between 102- and 103-fold in the detection limits for furnace AAS compared with flame AAS. [Pg.788]

In the analysis of polymer surfaces and interfaces there has been tremendous progress in recent years. This is to a large extent due to the development of surface- and interface-sensitive analytical techniques which previously had not been applied to polymers. It is thus possible to achieve molecular resolution both for the free polymer surface and for buried interfaces between polymers. In addition, suitable sample preparation techniques are available and extremely homogeneous and smooth polymer thin films can be prepared. They may be put together to investigate the interface between polymers. [Pg.394]

Brain et al. [137] reported a tandem mass spectrometry (MS-MS) procedure by which a direct measurement from an n-pentane extract of a surfactant is possible. This procedure is excellent from the standpoint of sensitivity and simplicity of sample preparation but is not commonly applied because of the need of an MS-MS instrument. [Pg.448]

Analysis of methyl parathion in sediments, soils, foods, and plant and animal tissues poses problems with extraction from the sample matrix, cleanup of samples, and selective detection. Sediments and soils have been analyzed primarily by GC/ECD or GC/FPD. Food, plant, and animal tissues have been analyzed primarily by GC/thermionic detector or GC/FPD, the recommended methods of the Association of Official Analytical Chemists (AOAC). Various extraction and cleanup methods (AOAC 1984 Belisle and Swineford 1988 Capriel et al. 1986 Kadoum 1968) and separation and detection techniques (Alak and Vo-Dinh 1987 Betowski and Jones 1988 Clark et al. 1985 Gillespie and Walters 1986 Koen and Huber 1970 Stan 1989 Stan and Mrowetz 1983 Udaya and Nanda 1981) have been used in an attempt to simplify sample preparation and improve sensitivity, reliability, and selectivity. A detection limit in the low-ppb range and recoveries of 100% were achieved in soil and plant and animal tissue by Kadoum (1968). GC/ECD analysis following extraction, cleanup, and partitioning with a hexane-acetonitrile system was used. [Pg.181]

State-of-the-art TOF-SIMS instruments feature surface sensitivities well below one ppm of a mono layer, mass resolutions well above 10,000, mass accuracies in the ppm range, and lateral and depth resolutions below 100 nm and 1 nm, respectively. They can be applied to a wide variety of materials, all kinds of sample geometries, and to both conductors and insulators without requiring any sample preparation or pretreatment. TOF-SIMS combines high lateral and depth resolution with the extreme sensitivity and variety of information supplied by mass spectrometry (all elements, isotopes, molecules). This combination makes TOF-SIMS a unique technique for surface and thin film analysis, supplying information which is inaccessible by any other surface analytical technique, for example EDX, AES, or XPS. [Pg.33]

P-Endosulfan has also been measured in hand rinsings using GC/ECD (Kazen et al. 1974). Sample preparation involves hand rinses with hexane followed by concentration, fractionation, and clean-up with Florisil . Sensitivity, recovery, and precision data were not reported. [Pg.249]

Several methods are available for the analysis of trichloroethylene in biological media. The method of choice depends on the nature of the sample matrix cost of analysis required precision, accuracy, and detection limit and turnaround time of the method. The main analytical method used to analyze for the presence of trichloroethylene and its metabolites, trichloroethanol and TCA, in biological samples is separation by gas chromatography (GC) combined with detection by mass spectrometry (MS) or electron capture detection (ECD). Trichloroethylene and/or its metabolites have been detected in exhaled air, blood, urine, breast milk, and tissues. Details on sample preparation, analytical method, and sensitivity and accuracy of selected methods are provided in Table 6-1. [Pg.229]

It is true that these X-ray procedures are much less sensitive to sample preparation them chemisorption techniques. Nonetheless, it is desirable to use them in conjunction with such methods. In analysis of chemisorption data, it is necessary to make an assumption as to the number of gas molecules that attach to each atom in the catalyst. [Pg.387]


See other pages where Sample preparation sensitivity is mentioned: [Pg.276]    [Pg.235]    [Pg.84]    [Pg.276]    [Pg.235]    [Pg.84]    [Pg.286]    [Pg.49]    [Pg.198]    [Pg.354]    [Pg.315]    [Pg.189]    [Pg.250]    [Pg.592]    [Pg.221]    [Pg.54]    [Pg.232]    [Pg.232]    [Pg.252]    [Pg.286]    [Pg.290]    [Pg.290]    [Pg.25]    [Pg.1029]    [Pg.379]    [Pg.180]    [Pg.211]    [Pg.86]    [Pg.178]    [Pg.181]    [Pg.30]    [Pg.28]    [Pg.147]    [Pg.332]    [Pg.152]    [Pg.169]   
See also in sourсe #XX -- [ Pg.146 ]




SEARCH



Sampling sensitivity

Sensitive preparation

Sensitizer preparation

© 2024 chempedia.info