Sample preparation chromatographic techniques

Analytical Techniques. Sorbic acid and potassium sorbate are assayed titrimetricaHy (51). The quantitative analysis of sorbic acid in food or beverages, which may require solvent extraction or steam distillation (52,53), employs various techniques. The two classical methods are both spectrophotometric (54—56). In the ultraviolet method, the prepared sample is acidified and the sorbic acid is measured at 250 260 nm. In the colorimetric method, the sorbic acid in the prepared sample is oxidized and then reacts with thiobarbituric acid the complex is measured at - 530 nm. Chromatographic techniques are also used for the analysis of sorbic acid. High pressure Hquid chromatography with ultraviolet detection is used to separate and quantify sorbic acid from other ultraviolet-absorbing species (57—59). Sorbic acid in food extracts is deterrnined by gas chromatography with flame ionization detection (60—62). [Pg.284]

Application of rotating coiled columns has become attractive for preparative-scale separations of various substances from different samples (natural products, food and environmental samples) due to advantages over traditional liquid-liquid extraction methods and other chromatographic techniques. The studies mainly made during the last fifteen years have shown that using rotating coiled columns is also promising for analytical chemistry, particularly for the extraction, separation and pre-concentration of substances to be determined (analytes) before their on-line or off-line analysis by different determination techniques. [Pg.247]

Chlorophenoxy acids are relatively polar pesticides which are usually determined by LC because volatile derivatives have to be prepared for GC analysis. This group of herbicides can be detected by multiresidue methods combined with automated procedures for sample clean-up, although selectivity and sensitivity can be enhanced by coupled-column chromatographic techniques (52). The experimental conditions for Such analyses are shown in Table 13.1. [Pg.353]

In order to reduce or eliminate off-line sample preparation, multidimensional chromatographic techniques have been employed in these difficult analyses. LC-GC has been employed in numerous applications that involve the analysis of poisonous compounds or metabolites from biological matrices such as fats and tissues, while GC-GC has been employed for complex samples, such as arson propellants and for samples in which special selectivity, such as chiral recognition, is required. Other techniques include on-line sample preparation methods, such as supercritical fluid extraction (SFE)-GC and LC-GC-GC. In many of these applications, the chromatographic method is coupled to mass spectrometry or another spectrometiic detector for final confirmation of the analyte identity, as required by many courts of law. [Pg.407]

The sample preparation in LC analysis is as important as the chromatographic separation itself. The procedure will often require considerable skill copied with a basic understanding of chromatographic methodology. The analyst will need to have some familiarity with micro techniques including general micro-manipulation, microfiltration, centrifugation and derivatization. [Pg.195]

Current interest in supercritical fluid extraction as a sample preparation technique for chromatographic analysis is intense, in spite of it receiving very little tion until the mid-1980s. Although neglected by analytical cl Hsts, during the... [Pg.408]

Solubilizing all or part of a sample matrix by contacting with liquids is one of the most widely used sample preparation techniques for gases, vapors, liquids or solids. Additional selectivity is possible by distributing the sample between pairs of immiscible liquids in which the analyte and its matrix have different solubilities. Equipment requirements are generally very simple for solvent extraction techniques. Table 8.2 [4,10], and solutions are easy to manipulate, convenient to inject into chromatographic instruments, and even small volumes of liquids can be measured accurately. Solids can be recovered from volatile solvents by evaporation. Since relatively large solvent volumes are used in most extraction procedures, solvent impurities, contaminants, etc., are always a common cause for concern [65,66]. [Pg.891]

The main characteristics of the ideal extraction method are given in Table 3.47, which at the same time are also criteria for comparison of sample preparation techniques. It is unlikely that a unique best method can be defined, which is analyte and matrix independent. Extraction is affected by polymer functionality, molecular weight and cross-linking. Selective extraction of some additives is basically not possible. Hence, the goal of an ideal extraction would be the complete extraction of all additives from the polymer for subsequent chromatographic separation. [Pg.134]

Gas chromatographic analysis starts with introduction of the sample on the column, with or without sample preparation steps. The choice of inlet system will be dictated primarily by the characteristics of the sample after any preparation steps outside the inlet. Clearly, sample preparation has a profound influence on the choice of injection technique. For example, analysts may skip the solvent evaporation step after extraction by eliminating solvent in the inlet with splitless transfer into the column. Sample introduction techniques are essentially of two types conventional and programmed temperature sample introduction. Vogt et al. [89] first described the latter in 1979. Injection of samples, which... [Pg.187]

Principles and Characteristics Although early published methods using SPE for sample preparation avoided use of GC because of the reported lack of cleanliness of the extraction device, SPE-GC is now a mature technique. Off-line SPE-GC is well documented [62,63] but less attractive, mainly in terms of analyte detectability (only an aliquot of the extract is injected into the chromatograph), precision, miniaturisation and automation, and solvent consumption. The interface of SPE with GC consists of a transfer capillary introduced into a retention gap via an on-column injector. Automated SPE may be interfaced to GC-MS using a PTV injector for large-volume injection [64]. LVI actually is the basic and critical step in any SPE-to-GC transfer of analytes. Suitable solvents for LVI-GC include pentane, hexane, methyl- and ethylacetate, and diethyl or methyl-f-butyl ether. Large-volume PTV permits injection of some 100 iL of sample extract, a 100-fold increase compared to conventional GC injection. Consequently, detection limits can be improved by a factor of 100, without... [Pg.436]


See other pages where Sample preparation chromatographic techniques is mentioned: [Pg.432]    [Pg.3419]    [Pg.42]    [Pg.247]    [Pg.355]    [Pg.354]    [Pg.5343]    [Pg.16]    [Pg.139]    [Pg.41]    [Pg.136]    [Pg.217]    [Pg.265]    [Pg.290]    [Pg.407]    [Pg.2]    [Pg.147]    [Pg.163]    [Pg.80]    [Pg.429]    [Pg.748]    [Pg.25]    [Pg.884]    [Pg.205]    [Pg.24]    [Pg.54]    [Pg.88]    [Pg.135]    [Pg.176]    [Pg.182]    [Pg.226]    [Pg.232]    [Pg.246]    [Pg.306]    [Pg.429]    [Pg.429]    [Pg.429]    [Pg.430]    [Pg.431]    [Pg.431]   