Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sample consistent

The mean and standard deviation for this sample are, respectively, 3.117 g and 0.051 g. Since the sample consists of seven measurements, there are six degrees... [Pg.80]

A series of samples consisting of any possible combination of KCl, NaCl, and NH4CI is to be analyzed by adding AgN03 to precipitate AgCl. What is the minimum volume of 5% w/v AgN03 necessary to completely precipitate the chloride in any 0.5-g sample ... [Pg.269]

According to EPA, "The maximum acceptable concentrations of PCB in any sample consisting of a homogenate of 25 or more whole fish of any species that is consumed by fish-eating birds and mammals, within the size range consumed is 0.5 mg/kg on a net weight basis."... [Pg.289]

Rotating Beam Fatigue Test for Steel Cords. The purpose of this test method is to evaluate steel cord for pure bending fatigue (121). The test sample consists of a 3-mm diameter mbber embedded with steel cord. Different bending stress levels are appHed and the time to failure is recorded. The test stops at 1.44 million cycles. The fatigue limit is calculated from S—N (stress—number of cycles) curve. [Pg.90]

Figure 4.29. Sample assembly for optical shock temperature measurements. The sample consists of a metal film deposited on a transparent substrate which serves as both an anvil and a transparent window through which thermal radiation is emitted. Rapid compression of gases and surface irregularities at the interface between the sample film and the driver produce very high temperatures in this region. The bottom portion of the figure illustrates the thermal distribution across through the assembly. (After Bass et al. (1987).)... Figure 4.29. Sample assembly for optical shock temperature measurements. The sample consists of a metal film deposited on a transparent substrate which serves as both an anvil and a transparent window through which thermal radiation is emitted. Rapid compression of gases and surface irregularities at the interface between the sample film and the driver produce very high temperatures in this region. The bottom portion of the figure illustrates the thermal distribution across through the assembly. (After Bass et al. (1987).)...
Representative sampling consistent with intended interpretation of measurement... [Pg.547]

Physical and/or chemical conditioning of sample consistent with analytical operation, with controlled and/or known effects on sample integrity... [Pg.547]

Figure 4 RBS spectra from a sample consisting of 240 nm of Si on 170 nm of Si02 on a Si substrate. The spectrum in (a) was acquired using a scattering angle of 160° while the spectrum in (b) used a detector angle of 110°. This sample was implanted with 2.50 x 10 As atoms/cm, but the Aa peak cannot be positively identified from either spectrum alone. Only As at a depth of 140 nm will produce the correct peak in both spectra. Figure 4 RBS spectra from a sample consisting of 240 nm of Si on 170 nm of Si02 on a Si substrate. The spectrum in (a) was acquired using a scattering angle of 160° while the spectrum in (b) used a detector angle of 110°. This sample was implanted with 2.50 x 10 As atoms/cm, but the Aa peak cannot be positively identified from either spectrum alone. Only As at a depth of 140 nm will produce the correct peak in both spectra.
As in RBS analysis, ERS can provide information on the atomic concentration of hydrogen as a function of depth (measured in atoms/cm ). This is derived from the height Aobs°f ERS spectrum (counts per channel), at energies corresponding to particular depths within the sample (see Figure 3c). For a sample consisting of H and another material X, with composition the spectrum height... [Pg.494]

In polycrystalline solids or samples consisting of various phases, each grain may sputter at a different rate producing extensive roughness in the bottom of the cra-... [Pg.544]

As a second example, results from a TOP ERDA measurement for a multi-element sample are shown in Fig. 3.65 [3.171]. The sample consists of different metal-metal oxide layers on a boron silicate glass. The projectiles are 120-MeV Kr ions. It can be seen that many different recoil ions can be separated from the most intense line, produced by the scattered projectiles. Figure 3.66 shows the energy spectra for O and Al recoils calculated from the measured TOF spectra, together with simulated spectra using the SIMNRA code. The concentration and thickness of the O and Al layers are obtained from the simulations. [Pg.169]

Fig. 23. Experimental room temperature Raman spectrum from a sample consisting primarily of bundles or ropes of single-wall nanotubes with diameters near that of the (10,10) nanotube. The excitation laser wavelength is 514.5 nm. The inset shows the lineshape analysis of the vibrational modes near 1580 cm . SWNT refers to singlewall carbon nanotubes [195]. Fig. 23. Experimental room temperature Raman spectrum from a sample consisting primarily of bundles or ropes of single-wall nanotubes with diameters near that of the (10,10) nanotube. The excitation laser wavelength is 514.5 nm. The inset shows the lineshape analysis of the vibrational modes near 1580 cm . SWNT refers to singlewall carbon nanotubes [195].
If the sample consisted of pure mobile phase containing no solute, then Xj = 0 and... [Pg.197]

The predominant species observed in SIMS spectra are singly charged atomic and molecular ions [51], However, inorganic and organic cluster ions can also be formed. If the sample consists of a simple single-component metal, then clusters such as M, M, etc., are observed in addition to M+ [52], Oxidation of the metal results in formation of MO ", MO/, M Oll", etc. The relative yield of MO+ to M+ depends on the bond dissociation energy of the oxide [52], For a two-component, oxidized metal, clusters of the type M/", M N, MjO, and M N O/ are observed [51]. [Pg.297]

The contractor at Site H had established area and personnel sampling consistent with HAZWOPER requirements. A photo ionization detector (PID) and a real-time aerosol monitor (RAM) were used on a daily basis to screen for potentially hazardous levels of contaminants. On a weekly basis, personal air samples were collected and submitted for laboratory analysis. PPE requirements, however, were often not based on this data because the oversight agency had established inflexible minimum PPE requirements. The audit team found many of the PPE requirements on Site H to be excessive in light of site monitoring data and hazard determinations. [Pg.190]

FIGURE 7.18 Preparative separation of abnegates from monomer of human IgG on a Fractogel EMD BioSEC (S) column (1000 X 50 mm column volume 1.88 liter). Five milliliters of a sample consisting of IgG (10 mg/ml) was applied at a flow rate of 10 ml/min (21.4 cm/hr) to remove aggregates (eluent 20 mM sodium phosphate, 0.1 At sodium chloride, pH 7.2). [Pg.242]

Figure 11.15 Cation-exchange mia O-LC analysis of a mixture of model proteins (a) the original sample consisting of myoglobin (M), cytochrome C (C) and lysozyme (L) (b) and (c) proteins adsorbed on to and then released from the polyaaylic acid coated fibre with exti ac-tion times of 5 and 240 s, respectively. Reprinted from Journal of Microcolumn Separations, 8, J.-L. Liao et al., Solid phase mia O exti action of biopolymers, exemplified with adsorption of basic proteins onto a fiber coated with polyaaylic acid, pp. 1-4, 1996, with permission from Jolm Wiley Sons, New York. Figure 11.15 Cation-exchange mia O-LC analysis of a mixture of model proteins (a) the original sample consisting of myoglobin (M), cytochrome C (C) and lysozyme (L) (b) and (c) proteins adsorbed on to and then released from the polyaaylic acid coated fibre with exti ac-tion times of 5 and 240 s, respectively. Reprinted from Journal of Microcolumn Separations, 8, J.-L. Liao et al., Solid phase mia O exti action of biopolymers, exemplified with adsorption of basic proteins onto a fiber coated with polyaaylic acid, pp. 1-4, 1996, with permission from Jolm Wiley Sons, New York.
At temperatures greater than -10°C, the Cs NMR spectrum of a Cs-exchanged hectorite in contact with l.OM CsCl solution (a slurry sample) consists of two peaks, one between 3.5 and... [Pg.158]

In general terms, the pyroelectric coefficient of a free sample consists of three components. The first, called the real coefficient, depends on the derivative of spontaneous polarization with respect to the temperature. The second is derived from the temperature dilatation and can be calculated based on mechanical parameters. The third coefficient is related to the piezoelectric effect and results from the temperature gradient that exists along the polar axis of the ciystal. [Pg.249]

It can be seen that pristine NG7 surface contains mostly (53 percent) aromatic carbon, about 20 percent each of CH and COH groups—only 4.8 percent of CO groups, and no COOH groups. The 34 percent burnt sample consists of mostly CO... [Pg.438]

The first thing we have to decide is whether these matrices should be organized column-wise or row-wise. The spectrum of a single sample consists of the individual absorbance values for each wavelength at which the sample was measured. Should we place this set of absorbance values into the absorbance matrix so that they comprise a column in the matrix, or should we place them into the absorbance matrix so that they comprise a row We have to make the same decision for the concentration matrix. Should the concentration values of the components of each sample be placed into the concentration matrix as a row or as a column in the matrix The decision is totally arbitrary, because we can formulate the various mathematical operations for either row-wise or column-wise data organization. But we do have to choose one or the other. Since Murphy established his laws long before chemometricians came on the scene, it should be no surprise that both conventions are commonly employed throughout the literature ... [Pg.8]

Hence, the extension of an isotropic unoriented partially crystalline polymer leads to the formation of a highly organized material with a characteristic fibrillar structure. The anisotropy of the sample as a whole is expressed by a higher modulus, tenacity and optical anisotropy. It would seem that the increase in strength in the drawing direction suggests that the oriented samples consist of completely extended chains. However, while the strength of such perfect structure for polyethylene has been evaluated as 13000 MPas), the observed values for an oriented sample are 50 to 30 MPa. [Pg.212]

FIGURE E.2 Each sample consists of 1 mol of atoms of the element. Clockwise from the upper right are 32 g of sulfur,... [Pg.63]

Samples consisting of 1 mol N, and 1 mol CH4 are in identical but separate containers, with initial temperatures of 500. K. Both gases gain 1200. J of heat at constant volume. Do the gases have the same final temperature If not, which gas has the higher final temperature Justify your reasoning. [Pg.379]

A sample consisting of 155 mg of a purified protein is dissolved in 10.0 mL of ethanol. This solution is placed in a device for measuring osmotic pressure and rises to a final height of 32.5 cm above the level of pure ethanol. The experiment is performed at 1.00 atm and 298 K. The density of ethanol at 298 K is 0.79 g-cm "3. What is the molar mass of the protein Assume that the density of the solution is the same as that of pure ethanol. See Exercise 8.95. [Pg.472]

If the sample consists of atoms of one element, the mass spectrum gives the isotopic distribution of the sample. The relative molar masses of the isotopes can be determined by comparison with atoms of carbon-12. If the sample is a compound, the formula and structure of the compound can be determined by studying the fragments. For example, the + 1 ions that CH4 could produce are CH4, CH3+, CH, CFI4, C+, and H4. Some of the particles that strike the detector are those that result when the molecule simply loses an electron (for example, to produce Cl I4+ from methane) ... [Pg.871]

In the United States, the threshold mercury concentration for commercial sale of fish is determined by the Food and Drag Administration, whereas consumption advice for recreational (noncommercial) fish is developed by individual states and tribes. Mercury data collected for development of fish-consumption advisories are typically from analyses of filets (axial muscle tissue, with or without skin) for total mercury, with concentrations expressed on a wet-weight basis. Analysis of filets for total mercury yields a valid estimate of MeHg concentration (Grieb et al. 1990 Bloom 1992), whether the analyzed sample consists of a large filet or a small mass of tissue obtained with a biopsy needle (Cizdziel et al. 2002 Baker et al. 2004). [Pg.93]

In the oxamyl tomato study, the DFR samples were obtained using a 5-cm Birkestrand sampler (10-cm disk size using the upper and lower surfaces). The sample consisted of 40 leaf disks or 400 cm from each subplot. The samples were collected impartially or in a nondirected approach from the middle two rows. The plot was four rows wide and the tractor came into contact with the first and fourth rows as the application was made. The middle two rows should be undisturbed by this movement and should therefore provide a more representative sample. [Pg.966]


See other pages where Sample consistent is mentioned: [Pg.1779]    [Pg.186]    [Pg.229]    [Pg.127]    [Pg.90]    [Pg.90]    [Pg.90]    [Pg.196]    [Pg.127]    [Pg.125]    [Pg.226]    [Pg.243]    [Pg.467]    [Pg.240]    [Pg.390]    [Pg.139]    [Pg.462]    [Pg.901]    [Pg.309]    [Pg.421]    [Pg.57]    [Pg.58]    [Pg.259]   
See also in sourсe #XX -- [ Pg.2 , Pg.11 , Pg.13 ]




SEARCH



Monte Carlo Sampling of the Single-Chain Partition Function and Self-Consistent Brownian Dynamics

© 2024 chempedia.info