Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Ready

At present the Cobas Ready consumes S to 6 xl of serum or plasma per test, depending on the chemistry performed. This volume is automatically pipetted by the built-in autosampler, which avoids the need of manual pipetting and therefore of eventual operator-to-operator pipetting variations. [Pg.22]

Multi-test reagent strips of the Cobas Ready system [Pg.22]

Heart CARD Cholesterol, urea, total protein, AST, CK, LDH [Pg.22]

Liver LIVER Total bilirubin, total protein, albumin, AST, ALT, LDH [Pg.22]

Kidney RENAL Urea, albumin, uric acid, total protein, creatinine [Pg.22]


SHINSKEY Feedback Controllers for the Process Industries SHUGAR, DEAN The Chemist s Ready Reference Handbook SHUGAR, BALLINGER The Chemical Technicians Ready Reference Handbook... [Pg.462]

Vaska s compound, tri7rt5-[Ir(CO)(Ph3P)2Cl]. Undergoes ready oxidative addition to give Ir(IlI) complexes. [Pg.418]

Beside all technical reasons the big advantage of a pneumatic test is, that the steam drums can remain within the line because first we have no additional load for the bearing and only small adjustments (for the connection with the pressurisation unit and the tightening of the man ways for the applied low temperature gas test) have to be done to make the drum ready for a pneumatic loading. The pressurised air is available in every paper mill and even if the maximum pressure does not fit, the use of a compressor or pressure bottles produce no problems. [Pg.32]

When network weights have been trained to appropriate values, the NSC is ready to start classifying. The data set to be classified is specified in the same manner as previously used for the training and validation sets. The classifier is applied to data through the use of a menu and generates a list including filenames, suggested class and the neuron outputs from the output layer (used for decision). The result is currently presented in a simple text editor, from which it can be saved and included in other documents. [Pg.107]

The operation is quite simple One sets the frequency to the lowest value, adjusts the gain and phase to the desired sensitivity using a special calibration standard discussed below and performs a zero-compensation on a defect free zone of the standard. Now one is ready to test. As one slides the probe across the surface of an aluminum structure, a signal response will be indicative of the presence of corrosion or of the presence of a subsurface edge. [Pg.286]

The three-part draft of the radioscopy standard pr EN 13068 is ready for the necessary european inquiries. This standard covers the requirements placed on the imaging system, the checking procedures as to the performance of the entire system and also the specifications of user guidelines for certain inspection tasks. The standard remains open to the definition of new inspection classes for future application cases. [Pg.441]

The tubes of the new MCB series are a highly integrated and reliable ready-to-use component for radiation applications, which until now were not feasible due to the lack of robustness, size, or stability requirements. [Pg.532]

The metal vacuum envelope is grounded and can be made quite thick. Even radiation-tight designs are feasible. The tube ean be shipped ready-to-use with a bonded cable. [Pg.534]

When a block is inside, the entrance panel is closed and the inspection is ready to start. The inside of the stainless steel X-ray tubehead housing is clad in lead with an on/ofT shutter in front of a thin plastic X-ray window. The thin window is to ensure the IP 65 classification. The window is of plastic that is not affected by the cleaning agents. The on/off shutter is interlocked with the entrance and exit panels so X-rays can be kept on at all times without risk of radiation leakage or exposure of the frozen fish blocks prior to the actual inspection. [Pg.591]

RF Technical Physics and Automation Research Institute is ready to production and supply computer industrial tomograph, scanning devices, measuring units, soft-hardware interfaces connecting the measuring units with computer and the adapted program complexes for the industrial tomography. [Pg.601]

For the testing of the ready pistons the conventional method are used. In this... [Pg.884]

Redaction of the draft was finished during the meeting of September 1997, and it has been sent for two-month enquiry in December 1997. The ad hoc group is now expecting the comments drawn by this enquiry to proceed to the revision of the document and to get it ready for six-month enquiry. [Pg.924]

Here, r is positive and there is thus an increased vapor pressure. In the case of water, P/ is about 1.001 if r is 10" cm, 1.011 if r is 10" cm, and 1.114 if r is 10 cm or 100 A. The effect has been verified experimentally for several liquids [20], down to radii of the order of 0.1 m, and indirect measurements have verified the Kelvin equation for R values down to about 30 A [19]. The phenomenon provides a ready explanation for the ability of vapors to supersaturate. The formation of a new liquid phase begins with small clusters that may grow or aggregate into droplets. In the absence of dust or other foreign surfaces, there will be an activation energy for the formation of these small clusters corresponding to the increased free energy due to the curvature of the surface (see Section IX-2). [Pg.54]

Central to all SPMs (or local probe methods , or local proximal probes as they are sometimes called) is the presence of a tip or sensor, typically of less than 100 mn radius, that is rastered in close proximity to—or in contact with—tire sample s surface. This set-up enables a particular physical property to be measured and imaged over the scaimed area. Crucial to the development of this family of teclmiques were both the ready availability of piezoelements, with which the probe can be rastered with subnanometre precision, and the highly developed computers and stable electronics of the 1980s, without which the operation of SPMs as we know them would not have been possible. [Pg.1676]

At this stage, we are ready to prove that Kramers theorem holds also for the total angular momentum F. We will do it by reductio ad absurdum. Then, let Itte) be the eigenvector of H with eigenvalue E,... [Pg.564]

Pure hydrazoic acid is a colourless liquid, b.p. 310 K. It is very ready to detonate violently when subjected to even slight shock, and so is used in aqueous solution. It is a weak acid, reacting with alkali to give azides, which contain the ion Nj. [Pg.224]

After these preliminaries we are now ready for a mathematically precise definition of an almost invariant set. Let p M he any probability measure. Wc say that the set B is 5-almost invariant with respect to p if... [Pg.105]

Living calculated the integrals, we are now ready to start the SCF calculation. To formulate the Fock mahix it is necessary to have an initial guess of the density matrix, P. The simplest approach is to use the null matrix in which all elements are zero. In this initial step the Fock nulrix F is therefore equal to... [Pg.83]

This completes one complete cycle of the genetic algorithm. The new papulation then becomes the current population ready for a new cycle. The algorithm repeatedly applies this sequence for a predetermined number of iterations and/or until it com erges. [Pg.497]

Identificatioii by Mixed Melting-points. It will be clear that melting-point determinations afford a ready method of identifying minute quantities of a solid compound, if the probable identity of this compound is already suspected. Thus if there is reason to believe that a particular substance is, for example. [Pg.5]

The column of resin must now be regenerated, i.e. the retained ions must be removed by passing an excess of regenerant (in this case 10% HCl) down the column as described above. The column is then washed with water and is ready for a new cycle of operations. Note that the column must not be allowed to become dry. [Pg.57]

Chloroform was formerly used in medicine as an anaesthetic. One disadvantage for this purpose is the ready oxidation which chloroform undergoes on exposure to light and air, generating the poisonous phosgene, or carbonyl chloride, COCU- This is counteracted by storing the liquid in dark amber-... [Pg.91]

Although the acetylation of alcohols and amines by acetic anhydride is almost invariably carried out under anhydrous conditions owing to the ready hydrolysis of the anhydride, it has been shown by Chattaway (1931) that phenols, when dissolved in aqueous sodium hydroxide solution and shaken with acetic anhydride, undergo rapid and almost quantitative acetylation if ice is present to keep the temperature low throughout the reaction. The success of this method is due primarily to the acidic nature of the phenols, which enables them to form soluble sodium derivatives, capable of reacting with the acetic... [Pg.109]

Lithium aluminium hydride, LiAlH, is a very active reducing agent, and is used particularly for the ready reduction of carboxylic acids (or their esters) to primary alcohols R-COOH -> R CH,OH. [Pg.155]

Aniline undergoes very ready nuclear substitution by bromine even in the cold, the bromine atoms entering the two ortho positions and the para position with the formation of symmetric or 2,4.6-tribromoaniline. The presence... [Pg.165]

Acetanilide also undergoes ready bromination, with the formation of a mixture of o- and /(-bromoacetanilidc. The ortho compound is formed in only... [Pg.166]

One of the characteristic properties of phenol is the ease with which it gives substitution products, this property being particularly well shown by the ready nitration, sulphonation and bromination which the benzene ring in the phenol molecule undergoes. [Pg.170]

Hydrolysis of Benzonitrile. Benzonitrile is moderately readily hydrolysed by 10% aqueous sodium hydroxide, but only slowly by hydrochloric acid (cf. p. 122). Ready hydrolysis is obtained by boiling the nitrile under reflux... [Pg.192]

Benzamide from Benzonitrile. (A) Although benzonitrile when boiled with 70% sulphuric acid undergoes ready hydrolysis to benzoic acid (see above), treatment with hot 90% sulphuric acid gives the intermediate benzamide. This difference arises partly from the difference in temperature employed, but also... [Pg.193]


See other pages where Ready is mentioned: [Pg.102]    [Pg.195]    [Pg.329]    [Pg.361]    [Pg.778]    [Pg.1164]    [Pg.1475]    [Pg.1530]    [Pg.1916]    [Pg.617]    [Pg.152]    [Pg.242]    [Pg.370]    [Pg.478]    [Pg.568]    [Pg.718]    [Pg.23]    [Pg.32]    [Pg.57]    [Pg.58]    [Pg.167]   


SEARCH



Readiness

© 2024 chempedia.info