Process plasma spectrometry

Atomic absorption provides very high sensitivity but requires careful subsampling, extensive sample preparation, and detailed sample-matrix corrections. X-ray fluorescence requires little in terms of sample preparation but suffers from low sensitivity and the application of major matrix corrections. Inductively coupled argon plasma spectrometry provides high sensitivity and few matrix corrections but requires a considerable amount of sample preparation, depending on the process stream to be analyzed. [Pg.276]

Chemically pure reagents were used. Cadmium was added as its sulfate salt in concentrations of about 50 ppm. Lanthanides were added as nitrates. For the experiments with other metal ions so-called "black acid from a Nissan-H process was used. In this acid a large number of metal ions were present. To achieve calcium sulfate precipitation two solutions, one consisting of calcium phosphate in phosphoric acid and the other of a phosphoric acid/sulfuric acid mixture, were fed simultaneously in the 1 liter MSMPR crystallizer. The power input by the turbine stirrer was 1 kW/m. The solid content was about 10%. Each experiment was conducted for at least 8 residence times to obtain a steady state. During the experiments lic iid and solid samples were taken for analysis by ICP (Inductively Coupled Plasma spectrometry, based on atomic emission) and/or INAA (Instrumental Neutron Activation Analysis). The solid samples were washed with saturated gypsum solution (3x) and with acetone (3x), and subsequently dried at 30 C. The details of the continuous crystallization experiments are given in ref. [5]. [Pg.384]

In this procedure (Soltanpour et al., 1982) the NH4HCO3 acts as both an extractant of Mo and a buffer, in a manner similar to the extraction of PO4. During extraction, the pH of the soil-AB-DTPA mixture increases to pH 8.5, dissolving calcium (Ca), aluminum (Al), and Fe molybdates (Soltanpour, 1991). Also, the HCO3- ions desorb molybdates from the surfaces of soil colloids. The DTPA may aid the Mo extraction process, but is included primarily for the extraction of multiple cations. Molybdenum determination is accomplished through use of inductively coupled plasma spectrometry (ICPS). The procedure has not been tested extensively on acid soils, but is outlined for use on alkaline or Mo-contaminated soils or spoils. [Pg.123]

The various oscillators differ mainly in the feedback process used. The two main types of oscillator used in plasma spectrometry are free running and crystal controlled . [Pg.158]

The various stages of this process depend critically on the type of gas, its pressure, and the configuration of the electrodes. (Their distance apart and their shapes control the size and shape of the applied electric field.) By controlling the various parameters, the discharge can be made to operate as a corona, a plasma, or an arc at atmospheric pressure. All three discharges can be used as ion sources in mass spectrometry. [Pg.43]

To examine a sample by inductively coupled plasma mass spectrometry (ICP/MS) or inductively coupled plasma atomic-emission spectroscopy (ICP/AES) the sample must be transported into the flame of a plasma torch. Once in the flame, sample molecules are literally ripped apart to form ions of their constituent elements. These fragmentation and ionization processes are described in Chapters 6 and 14. To introduce samples into the center of the (plasma) flame, they must be transported there as gases, as finely dispersed droplets of a solution, or as fine particulate matter. The various methods of sample introduction are described here in three parts — A, B, and C Chapters 15, 16, and 17 — to cover gases, solutions (liquids), and solids. Some types of sample inlets are multipurpose and can be used with gases and liquids or with liquids and solids, but others have been designed specifically for only one kind of analysis. However, the principles governing the operation of inlet systems fall into a small number of categories. This chapter discusses specifically substances that are normally liquids at ambient temperatures. This sort of inlet is the commonest in analytical work. [Pg.103]

Plasma torches and thermal ionization sources break down the substances into atoms and ionized atoms. Both are used for measurement of accurate isotope ratios. In the breakdown process, all structural information is lost, other than an identification of elements present (e.g., as in inductively coupled mass spectrometry, ICP/MS). [Pg.285]

All three types of discharge involve the formation of ions as part of the process. For various reasons, most of the ions are positive. The ions can be examined by mass spectrometry. If small amounts of a sample substance are introduced into a corona or plasma or arc, ions are formed by the electrons present in the discharge or by collision with ions of the discharge gas. [Pg.388]

This is the basic process in an inductively coupled plasma discharge (ICP). The excited ions can be examined by observing the emitted light or by mass spectrometry. Since the molecules have been broken down into their constituent atoms (as ions) including isotopes, these can be identified and quantified by mass spectrometry, as happens with isotope ratio measurements. [Pg.388]

Fig. 4. Examples of emission spectrometry as a diagnostic monitoring tool for plasma processing, (a) The removal of chlorine contamination from copper diode leads using a hydrogen—nitrogen plasma. Emissions are added together from several wavelengths, (b) The etching and eventual removal of a 50-p.m thick polyimide layer from an aluminum substrate, where (x ) and (° ) correspond to wavelengths (519.82 and 561.02 nm, respectively) for molecular CO2... Fig. 4. Examples of emission spectrometry as a diagnostic monitoring tool for plasma processing, (a) The removal of chlorine contamination from copper diode leads using a hydrogen—nitrogen plasma. Emissions are added together from several wavelengths, (b) The etching and eventual removal of a 50-p.m thick polyimide layer from an aluminum substrate, where (x ) and (° ) correspond to wavelengths (519.82 and 561.02 nm, respectively) for molecular CO2...
Inductively coupled argon plasma (icp) and direct current argon plasma (dcp) atomic emission spectrometry are solution techniques that have been appHed to copper-beryUium, nickel—beryUium, and aluminum—beryUium aUoys, beryUium compounds, and process solutions. The internal reference method, essential in spark source emission spectrometry, is also useful in minimizing drift in plasma emission spectrometry (17). Electrothermal (graphite... [Pg.68]

In order to relate material properties with plasma properties, several plasma diagnostic techniques are used. The main techniques for the characterization of silane-hydrogen deposition plasmas are optical spectroscopy, electrostatic probes, mass spectrometry, and ellipsometry [117, 286]. Optical emission spectroscopy (OES) is a noninvasive technique and has been developed for identification of Si, SiH, Si+, and species in the plasma. Active spectroscopy, such as laser induced fluorescence (LIF), also allows for the detection of radicals in the plasma. Mass spectrometry enables the study of ion and radical chemistry in the discharge, either ex situ or in situ. The Langmuir probe technique is simple and very suitable for measuring plasma characteristics in nonreactive plasmas. In case of silane plasma it can be used, but it is difficult. Ellipsometry is used to follow the deposition process in situ. [Pg.79]

In isotope dilution inductively coupled plasma-mass spectrometry (ID-ICP-MS) the spike, the unspiked and a spiked sample are measured by ICP-MS in order to determine the isotope ratio. Using this technique, more precise and accurate results can be obtained than by using a calibration graph or by standard addition. This is due to elimination of various systematic errors. Isotopes behave identically in most chemical and physical processes. Signal suppression and enhancement due to the matrix in ICP-MS affects both isotopes equally. The same holds for most long-term instrumental fluctuations and drift. Accuracy and precision obtained with ID-ICP-QMS are better than with other ICP-QMS calibration... [Pg.660]

Brenner et al. [ 169] applied inductively coupled plasma atomic emission spectrometry to the determination of calcium (and sulfate) in brines. The principal advantage of the technique was that it avoided tedious matrix matching of calibration standards when sulfate was determined indirectly by flame techniques. It also avoided time-consuming sample handling when the samples were processed by the gravimetric method. The detection limit was 70 ig/l and a linear dynamic range of 1 g/1 was obtained for sulfate. [Pg.156]

All four dissolution procedures studied were found to be suitable for arsenic determinations in biological marine samples, but only one (potassium hydroxide fusion) yielded accurate results for antimony in marine sediments and only two (sodium hydroxide fusion or a nitricperchloric-hydrofluoric acid digestion in sealed Teflon vessels) were appropriate for determination of selenium in marine sediments. Thus, the development of a single procedure for the simultaneous determination of arsenic, antimony and selenium (and perhaps other hydride-forming elements) in marine materials by hydride generation inductively coupled plasma atomic emission spectrometry requires careful consideration not only of the oxidation-reduction chemistry of these elements and its influence on the hydride generation process but also of the chemistry of dissolution of these elements. [Pg.357]


See other pages where Process plasma spectrometry is mentioned: [Pg.102]    [Pg.119]    [Pg.299]    [Pg.189]    [Pg.952]    [Pg.958]    [Pg.221]    [Pg.5]    [Pg.87]    [Pg.97]    [Pg.198]    [Pg.112]    [Pg.317]    [Pg.46]    [Pg.529]    [Pg.176]    [Pg.333]    [Pg.71]    [Pg.56]    [Pg.260]    [Pg.486]    [Pg.578]    [Pg.989]    [Pg.359]    [Pg.320]    [Pg.348]    [Pg.313]    [Pg.606]    [Pg.295]    [Pg.237]    [Pg.101]    [Pg.76]    [Pg.43]   