Preparation of the samples

Sample concentrations 20 mg/ml of protein are used, since lower concentrations do not give spectra with a good signal-to-noise ratio in aqueous solvent. Once prepared the solution is sealed in its container with parafilm and stored at 4°C. [Pg.212]


The system is equipped with an DEC- Alpha Station running at 400 MHz. Therefore the time for image reconstruction is not important compared to the time for data acquisition and preparation of the sample. [Pg.585]

The previous discussion demonstrates that measurement of precise isotope ratios requires a substantial amount of operator experience, particularly with samples that have not been examined previously. A choice of filament metal must be made, the preparation of the sample on the filament surface is important (particularly when activators are used), and the rate of evaporation (and therefore temperature control) may be crucial. Despite these challenges, this method of surface ionization is a useful technique for measuring precise isotope ratios for multiple isotopes. Other chapters in this book discuss practical details and applications. [Pg.52]

Every chromatographic investigation begins with the preparation of the sample and the chromatographic system. This is followed by the crux of the separation process (development of the chromatogram) which is in turn followed by the visualization of the separated substances and the preservation of the chromatogram and finally by the analysis of the results. [Pg.119]

We conclude that the preparation of the samples of the polymer composites with the corresponding electrical properties in the form, say, of the plates, bars, hollow cylinders, etc., that are usually used for the purpose of research in the laboratories, and of real articles should be considered as two interrelated problems. This is important and should be stressed, as the values of the conductivity and other parameters obtained for the simple forms might prove different for the forms that may be used as constructional elements. Therefore, these circumstances should be taken into account at the design stage of a conducting composite as well as the optimum technological techniques of molding of practically important articles. [Pg.131]

This study was supported by MURST (Rome-Italy). The authors thanks prof R.J. Willey of Northeastern University of Boston for the preparation of the samples via aerogel technique. [Pg.482]

A protocol must be established and followed for sample preparation, labeling, packaging, shipping, and chain-of-custody procedures. Also, the volume of the samples will be specified by the analytical laboratory depending on the analytical methods to be used and the desired sensitivity. Accordingly, principal attention will be given here to the sampling methods, preparation of the samples for analysis, and QA/QC aspects of both. [Pg.102]

However, this simplified reasoning does not meet the real situation of the analysis as a whole, where both the preparation of the sample and the renewal of the titration medium cause a certain and often considerable loss of time therefore, the following set of more or less well defined symbols are used (see Fig. 5.2. a and b for a signal S of first-order response) ... [Pg.321]

When dissection of fruits was involved in the preparation of the samples, the values reported represent the parts per million of toxicant based on fresh weight of the indicated component only and not of the weight of the whole fruit. As separated in these studies the peel of most citrus fruits constitutes approximately one sixth the weight of the whole fruits. [Pg.130]

Almost all applications of mass spectrometry in biochemistry and biomedicine require preparation of the samples prior to MS analysis. Sample preparation typically includes a number of steps to purify and concentrate target biomarker analytes. However, heme crystal formation, a unique evolutionary... [Pg.164]

Cell lysis When studying signaling components, it is important that the integrity and phosphorylation states of proteins of interest are not altered during cell lysis and the subsequent preparation of the samples prior to analysis. The principal precautions include the use of inhibitors of protein phosphatases and of proteases, in addition to working speedily and keeping samples cold (0 to 4°). [Pg.161]

A radiocarbon AMS measurement cannot occur without previous treatment or preparation of the sample to be dated. [Pg.473]

This analytical method, based on TXRF, enables a large number of trace elements to be determined simultaneously. The range is suitable for different areas of the sea. The motivation to use TXRF resulted mainly from the characteristic features of the method its high detection power, its universal calibration curve, which eliminates the need for matrix-dependent standard samples or standard-addition procedures, the simple preparation of the sample films, and of course the possibility of multielement determination. [Pg.279]

Great care is needed during the preparation of the sample, since dirt, adsorbed CO2 and other impurities can all contain additional sources of carbon. The dirt may come from the sample, or it could have been adsorbed during sample collection or even contamination during the dating procedure. The more recent the contamination, the higher the proportion of carbon that is radioactive 14C that has... [Pg.384]

Great care is needed during the preparation of the sample before dating to eliminate the possibility of contamination with additional sources of carbon. [Pg.384]

We are grateful to HASYLAB for offering beam time on the synchrotron radiation facility of DESY and for the access to the EXAFS spectrometer. We also thank J.W. 0rnbo for help in the preparation of the samples, N.-Y. Topsjzfe for helpful discussions, and 0. Sorensen for carrying out the electron microscopy investigations. [Pg.91]

The preparation of the sample prior to its analysis will depend upon the nature of both the sample and the analytical method chosen and may involve the disruption of cells, homogenization and extraction procedures as well as the removal of protein or other interfering substances. It may be necessary to prevent the decomposition and degradation of the carbohydrate content during such treatments or during storage by the addition of antibacterial agents such as thymol or merthiolate, or substances such as fluoride ions, which will inhibit the enzymic transformation of the carbohydrates. [Pg.306]

Tablets account for more than 80% of all pharmaceutical formulations therefore, the development and implementation of NIR methods for determining APIs in intact tablets is of a high interest with a view to assuring content uniformity and quality in the end product. Blanco et al developed an innovative strategy to prepare calibration samples for NIR analysis by using laboratory-made samples obtained by mixing the API and excipients in appropriate proportions and compacting the mixture at a pressure similar to that used industrially. This way of matching laboratory and production samples affords more simple and robust NIR methods which require the use of neither HPLC nor UV-vis spectroscopy as reference rather, reference values are obtained by weighing during preparation of the samples. The PLS calibration models thus constructed exhibited a good predictive ability with various production batches. Tablets account for more than 80% of all pharmaceutical formulations therefore, the development and implementation of NIR methods for determining APIs in intact tablets is of a high interest with a view to assuring content uniformity and quality in the end product. Blanco et al developed an innovative strategy to prepare calibration samples for NIR analysis by using laboratory-made samples obtained by mixing the API and excipients in appropriate proportions and compacting the mixture at a pressure similar to that used industrially. This way of matching laboratory and production samples affords more simple and robust NIR methods which require the use of neither HPLC nor UV-vis spectroscopy as reference rather, reference values are obtained by weighing during preparation of the samples. The PLS calibration models thus constructed exhibited a good predictive ability with various production batches.
First, a 50 ml solution was prepared of the sample V without (V-0) and with (V-A) antioxidants. The solution was poured into 12 sampling bottles and injected immediately and then every 2 hrs for 72 hrs. The variation of Mj s with time for these samples is shown in Figures 4 and 5, respectively. [Pg.101]

The total number of imperfections per unit surface characterizes what may be termed the disorder of the crystal surface. Two parts should be distinguished in the disorder biographical disorder, which is retained at the absolute zero of temperature and depends on the method of preparation of the sample and on its entire preceding history and thermal disorder, which increases on heating and is superposed on the biographical disorder. ... [Pg.255]

The selection and preparation of the samples very often is the most crucial item in an interlaboratory test. All characteristics that could affect the integrity of the test have to be considered. This includes homogeneity and stability, which are dealt with in detail later. The PT provider has to look for possible changes in and the effect of ambient conditions on the samples. [Pg.308]

Because the sampling error is usually the biggest error in the whole analysis, care must be taken to consider all aspects from sampling. Measurement uncertainties arising from the process of sampling and the physical preparation of the sample can be estimated. [Pg.342]

Qualitative and quantitative elemental analysis of polymers can be carried out by the conventional methods used for low-molecular-weight compounds. So a detailed description is not needed here. Elemental analysis or determination of functional groups is especially valuable for copolymers or chemically modified polymers. For homopolymers where the elemental analysis should agree with that of the monomer, deviations from the theoretical values are an indication of side reactions during polymerization. However, they can also sometimes be caused by inclusion or adsorption of solvent or precipitant, or, in commercial polymers, to the presence of added stabilizers. The preparation of the sample for... [Pg.86]

Kind permission for using the 2Q-HoMQC spectrum of apo-cytochrome c was received from Prof. Jannette Carey (Princeton University, NJ), while Xinshan Kang (Princeton University) contributed with preparation of the sample. This work was supported, in part, by the Exxon Education Foundation (I.P.). Special thanks are due to Lee Bickerstaff for critical reading of the manuscript. [Pg.206]

Two-phase particles ranging from 10 to 20 microns in size, supported on a graphite substrate, were observed in-situ in the UHV chamber of a scanning Auger microprobe. Both surface composition analysis and imaging of the particles could be undertaken. The preparation of the samples has been described in detail elsewhere. ... [Pg.56]

Fig. 9.4.26 Optical absorption spectra of Au-UFP/2-propano suspension as a function of time. The numbers in the figure are the passage of time after the preparation of the sample. The. sample colloids were prepared by a gas flow-solution trap method. (Front Ref. 27.)... Fig. 9.4.26 Optical absorption spectra of Au-UFP/2-propano suspension as a function of time. The numbers in the figure are the passage of time after the preparation of the sample. The. sample colloids were prepared by a gas flow-solution trap method. (Front Ref. 27.)...
Most of the analytical techniques applied in art conservation research require the preparation of the sample prior to the analysis step. Although the sample preparation procedures vary in a wide range, five basic types of procedures can be established grinding, dissolving, derivatizing, melting and embedding. [Pg.10]


See other pages where Preparation of the samples is mentioned: [Pg.1648]    [Pg.174]    [Pg.545]    [Pg.167]    [Pg.338]    [Pg.73]    [Pg.224]    [Pg.290]    [Pg.263]    [Pg.165]    [Pg.43]    [Pg.270]    [Pg.170]    [Pg.74]    [Pg.102]    [Pg.98]    [Pg.100]    [Pg.84]    [Pg.211]    [Pg.53]    [Pg.516]    [Pg.15]    [Pg.98]    [Pg.294]   
See also in sourсe #XX -- [ Pg.28 ]




SEARCH



Experiment 46 The Quantitative Determination of Methyl Paraben in a Prepared Sample by HPLC

Preparation and Characterization of the Samples

Preparation and handling of the samples

Preparation of samples

Preparation of the Mechano-Activated Silica Samples (MSi)

Preparation of the Reactive Silica (RSi) Samples

Preparation of the Sample for Irradiation

Preparation of the Soil Sample Ready for Ecotoxicity Testing

Preparation of the Thermo-Activated Silica (TSi) Samples

Rough preparation of the analytical sample

The Control of Sample Size for Normal Preparative Column Operation

The Sample