Power cables conduits

Cathodic Protection of the Steel Conduits for Power Cables... [Pg.336]

If feasible, raised panel computer-room type floors should not be used. Where raised floors must be used to accommodate wiring and cables, they should be constructed entirely of noncombustible materials and provided with floor panels easily removable by hand. Power distribution in the subfloor space should be in conduit. Redundant data highway cables should be run as remotely from each other as possible and not mixed with power cables. [Pg.304]

Electricallelectronic market. Glass fibers are used extensively in printed circuit boards, industrial circuit breakers, conduits for power cables, etc. [Pg.209]

Critical spacecraft systems and components that would be evaluated include pressurized vessels and conduits such as the reactor and piping, electrical equipment, reactor control drive mechanisms and power cables essential to mission success. It is anticipated that reactor protection wouid be one of the more significant design challenges, due to the importance of the continuous reactor operation, the... [Pg.538]

Electrical Applications. Plastics are used for electrical insulation, conduit and enclosures, lighting fixtures, and mechanical devices. The most widely used plastic for wire and cable insulation is flexible, plasticized PVC, which constitutes well over half the market in insulating wires for buildings, automobiles, appHances, and power and control lines. Polyethylene is also a factor. Higher performance plastics such as nylon and fluoropolymers also play a smaller role in this area. [Pg.333]

Seals are required at entries by conduit or cable to explosion-proof enclosures containing arcing or high-temperature devices in Division 1 and Division 2 locations. It is not required to seal IM in. or smaller conduits into explosion-proof enclosures in Division 1 areas housing switches, circuit breakers, fuses, relays, etc., if their current-interrupting contacts are hermetically sealed or under oil (having a 2-in. minimum immersion for power contacts and 1-in. for control contacts). [Pg.539]

The unit prices and unit hours represent composites of all materials and operations required for a finished product i.e., the motor hook-up units include the breakers, push button, a pro rata of the MCC cabinet conduits or cable trays, power and control wiring, terminators, miscellaneous supports, unloading and storing materials, testing and commissioning, etc. [Pg.303]

DC Power System Station Batteries Battery Chargers Distribution Switchboards Cabling and Conduit/Trays Essential DC Power System Station Batteries... [Pg.135]

Install critical power, control, instrument, and alarm wiring and pneumatic tubing outside the fire-exposed envelope. Cable trays and conduit banks should be routed underground or on the upper levels of elevated pipe racks at least 30 feet above the ground and outside the drainage path of hydrocarbon spills. Install fire proofing of critical systems and equipment if they are inside the fire-exposed envelope. [Pg.74]

Electrical layout for power, conduits, cables, etc. outside the reactor structure would be designed by ANL. ORNL would specify special power requirements for reactor control. [Pg.40]

Scenario Damage to culvert The main event selected for illustration in this paper is Damage to culvert/joint conduit of electric power, ICT, and water mains . This event is based on an actual event that occurred in Oslo on November 27th, 2007 An entrepreneur unwarily broke a cable when digging a ditch, and the cable break led to short circuit and fire at the Oslo S railway station (Oslo Central Station), further paralyzing the region s rail traffic and transportation systems for 20 hours, and the internet systems for about 10 hours (DSB 2008). [Pg.1769]

When the measuring and marking out is completed, the electrician can begin the process of installing the trunking, conduits, cables or tray, using the hand tools and power tools described previously in this chapter. [Pg.287]

Nowadays pipes are the invisible arteries of modern life for fresh water, for drainage and sewage, for the gas supply, and increasingly as conduits for electrical and fibre optic cables, for such things as power supply, television channels and motorway signalling. [Pg.20]

Main feeders and distribution feeders for localized switchboards and panelboards usually are run in rigid metal conduit. Large power blocks are distributed in busways. Where plant floor use or equipment is changed frequently, it often is advantageous to distribute all main feeders in the form of interlocked armored cable run in cable trays. [Pg.718]

The damage to electrical power and control circuits resulted in the loss of redundant subsystems and equipment. This was surprising in view of the independence and separation criteria that had been applied in the design of the plant. The two principal reasons for the failures were found to be (1) failure to recognize potential sources of failure of safety equipment (i.e., the interconnection of safety equipment and nonsafety circuits such as the indicator-light circuits) and (2) contrary to what had been considered good practice, the conduit used to isolate cables from their redundant counterparts did not protect the cables adequately. [Pg.123]


See other pages where Power cables conduits is mentioned: [Pg.345]    [Pg.69]    [Pg.632]    [Pg.345]    [Pg.1214]    [Pg.293]    [Pg.410]    [Pg.630]    [Pg.708]    [Pg.432]    [Pg.24]    [Pg.255]    [Pg.183]    [Pg.570]    [Pg.2866]    [Pg.1234]    [Pg.2356]    [Pg.395]    [Pg.386]    [Pg.742]    [Pg.192]    [Pg.434]    [Pg.526]   
See also in sourсe #XX -- [ Pg.45 , Pg.336 ]

See also in sourсe #XX -- [ Pg.45 , Pg.336 ]