Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Mains water

Water. Water mains should be connected to plant fire mains at two or more poiats, so that a sufficient water supply can be deHvered ia case of emergency. The plant loop and its branches should be adequately valved so that a break can be isolated without affecting a principal part of the system. If there is any question of maintaining adequate pressure, suitable booster pumps should be iastaHed. Any connection made to potable water for process water or cooling water must be made ia such a manner that there can be no backflow of possibly contaminated water check valves alone are not sufficient. The municipal supply should faH freely iato a tank from which the water is pumped for process purposes, or commercially available and approved backflow preventers should be used. [Pg.98]

After 1860 in the United States, water mains were only occasionally given coatings of tar. About 18% the activities of Engii.sh undertakings were extended to America, where chiefly bare metal pipelines had previously been laid. Water supply pipes were coated internally with bitumen in America after 1912. Vical (1837) in France and J. Bull (1843) in America introduced the widely known cement mortar as a protective material for water pipes 16]. [Pg.6]

Asbestos fiber > 10 micrometer 7 million fibers per liter 7MFL Increased risk of developing benign intestinal polyps Decay of asbestos cement in water mains erosion of natural deposits... [Pg.17]

In this type of humidifier, the water required for the humidification process is stored within the unit and is normally fed automatically from the water mains. However, smaller portable units do not have this automatic facility and have to be manually filled with water as required. [Pg.718]

To prevent contamination of the water mains by back-siphonage, the water inlet to the appliance should incorporate either... [Pg.720]

In another building, gusting winds caused transient increases in pressure that tripped the ventilation fans. The problem was overcome by increasing the fan speeds. Unfortunately the increased flow of cold air through a doorway cooled a fire water main so much that it froze and cracked [21 ]. [Pg.54]

Confirmation as to whether the water main passes through any adjacent property which may involve easements to gain access for maintenance, etc. [Pg.23]

In the US, maximum draw-off from water mains differs throughout the various water authorities. What may... [Pg.26]

Hard underground waters, mainly in the East and South of England, mostly from chalk, sandstone or limestone strata. [Pg.353]

All these rates are, of course, quite low and the problem with corrosion of cast iron water mains is its effect on water quality rather than deterioration of the asset. [Pg.360]

Williams, S. M., Ainsworth, R. G., and Elvidge, A. F., A method of assessing the corrosivity of water towards iron , Source document 3, Water Mains Rehabilitation Manual, Water Research Centre/Water Authorities Association (1986)... [Pg.362]

Tap water. As city water, mains supply, and the like, tap water is typically under 1,000 to 2,000 ppm TDS. It requires an RO plant operating with an applied pressure of 150 to 300 psig and permeate recovery rates of 80% down to perhaps 50% of the RW supplied... [Pg.364]

Figure 24.15 More complex problems might require a greater number of cooling water mains. Figure 24.15 More complex problems might require a greater number of cooling water mains.
Figure 26.19 The streams are connected with the water mains. Figure 26.19 The streams are connected with the water mains.
This simple example illustrates the basic principles of water network design for maximum reuse for a single contaminant. A number of issues need to be considered that would apply to more complex examples. Consider Figure 26.25 involving three water mains and three operations. Operation 2 above the pinch terminates at a concentration less than the concentration for the high concentration water main. The outlet of Operation 2 must not be fed directly into this final water main. The basis of the mass balance from Figure 26.17 dictates that all streams must achieve the concentration of the water mains into... [Pg.598]

Figure 26.22 Removing the intermediate water main allows the connections to be made directly. Figure 26.22 Removing the intermediate water main allows the connections to be made directly.

See other pages where Mains water is mentioned: [Pg.104]    [Pg.110]    [Pg.25]    [Pg.212]    [Pg.77]    [Pg.98]    [Pg.237]    [Pg.73]    [Pg.128]    [Pg.724]    [Pg.505]    [Pg.26]    [Pg.87]    [Pg.94]    [Pg.358]    [Pg.474]    [Pg.475]    [Pg.393]    [Pg.847]    [Pg.104]    [Pg.110]    [Pg.519]    [Pg.519]    [Pg.519]    [Pg.519]    [Pg.520]    [Pg.520]    [Pg.521]    [Pg.521]    [Pg.522]    [Pg.596]    [Pg.597]    [Pg.597]    [Pg.599]    [Pg.599]   
See also in sourсe #XX -- [ Pg.461 , Pg.462 , Pg.463 , Pg.464 , Pg.547 , Pg.548 ]

See also in sourсe #XX -- [ Pg.331 , Pg.332 , Pg.333 ]




SEARCH



© 2024 chempedia.info