Potentiometry potential

Potentiometry — Potential, E Solution composition film composition Redox potential, ion-exchange capacity... [Pg.534]

Finding the End Point Potentiometrically Another method for locating the end point of a redox titration is to use an appropriate electrode to monitor the change in electrochemical potential as titrant is added to a solution of analyte. The end point can then be found from a visual inspection of the titration curve. The simplest experimental design (Figure 9.38) consists of a Pt indicator electrode whose potential is governed by the analyte s or titrant s redox half-reaction, and a reference electrode that has a fixed potential. A further discussion of potentiometry is found in Chapter 11. [Pg.339]

The diversity of interfacial electrochemical methods is evident from the partial family tree shown in Figure 11.1. At the first level, interfacial electrochemical methods are divided into static methods and dynamic methods. In static methods no current passes between the electrodes, and the concentrations of species in the electrochemical cell remain unchanged, or static. Potentiometry, in which the potential of an electrochemical cell is measured under static conditions, is one of the most important quantitative electrochemical methods, and is discussed in detail in Section IIB. [Pg.462]

In potentiometry the potential of an electrochemical cell is measured under static conditions. Because no current, or only a negligible current, flows while measuring a solution s potential, its composition remains unchanged. For this reason, potentiometry is a useful quantitative method. The first quantitative potentiometric applications appeared soon after the formulation, in 1889, of the Nernst equation relating an electrochemical cell s potential to the concentration of electroactive species in the cell. ... [Pg.465]

When first developed, potentiometry was restricted to redox equilibria at metallic electrodes, limiting its application to a few ions. In 1906, Cremer discovered that a potential difference exists between the two sides of a thin glass membrane when opposite sides of the membrane are in contact with solutions containing different concentrations of H3O+. This discovery led to the development of the glass pH electrode in 1909. Other types of membranes also yield useful potentials. Kolthoff and Sanders, for example, showed in 1937 that pellets made from AgCl could be used to determine the concentration of Ag+. Electrodes based on membrane potentials are called ion-selective electrodes, and their continued development has extended potentiometry to a diverse array of analytes. [Pg.465]

Potentiometric measurements are made using a potentiometer to determine the difference in potential between a working or, indicator, electrode and a counter electrode (see Figure 11.2). Since no significant current flows in potentiometry, the role of the counter electrode is reduced to that of supplying a reference potential thus, the counter electrode is usually called the reference electrode. In this section we introduce the conventions used in describing potentiometric electrochemical cells and the relationship between the measured potential and concentration. [Pg.466]

In potentiometry, the concentration of analyte in the cathodic half-cell is generally unknown, and the measured cell potential is used to determine its concentration. Thus, if the potential for the cell in Figure 11.5 is measured at -1-1.50 V, and the concentration of Zn + remains at 0.0167 M, then the concentration of Ag+ is determined by making appropriate substitutions to equation 11.3... [Pg.469]

The potential of the indicator electrode in a potentiometric electrochemical cell is proportional to the concentration of analyte. Two classes of indicator electrodes are used in potentiometry metallic electrodes, which are the subject of this section, and ion-selective electrodes, which are covered in the next section. [Pg.473]

The potential of a metallic electrode is determined by the position of a redox reaction at the electrode-solution interface. Three types of metallic electrodes are commonly used in potentiometry, each of which is considered in the following discussion. [Pg.473]

Redox Electrodes Electrodes of the first and second kind develop a potential as the result of a redox reaction in which the metallic electrode undergoes a change in its oxidation state. Metallic electrodes also can serve simply as a source of, or a sink for, electrons in other redox reactions. Such electrodes are called redox electrodes. The Pt cathode in Example 11.1 is an example of a redox electrode because its potential is determined by the concentrations of Ee + and Ee + in the indicator half-cell. Note that the potential of a redox electrode generally responds to the concentration of more than one ion, limiting their usefulness for direct potentiometry. [Pg.475]

If metallic electrodes were the only useful class of indicator electrodes, potentiometry would be of limited applicability. The discovery, in 1906, that a thin glass membrane develops a potential, called a membrane potential, when opposite sides of the membrane are in contact with solutions of different pH led to the eventual development of a whole new class of indicator electrodes called ion-selective electrodes (ISEs). following the discovery of the glass pH electrode, ion-selective electrodes have been developed for a wide range of ions. Membrane electrodes also have been developed that respond to the concentration of molecular analytes by using a chemical reaction to generate an ion that can be monitored with an ion-selective electrode. The development of new membrane electrodes continues to be an active area of research. [Pg.475]

In potentiometry, the potential of an electrochemical cell under static conditions is used to determine an analyte s concentration. As seen in the preceding section, potentiometry is an important and frequently used quantitative method of analysis. Dynamic electrochemical methods, such as coulometry, voltammetry, and amper-ometry, in which current passes through the electrochemical cell, also are important analytical techniques. In this section we consider coulometric methods of analysis. Voltammetry and amperometry are covered in Section 1 ID. [Pg.496]

Electrical methods of analysis (apart from electrogravimetry referred to above) involve the measurement of current, voltage or resistance in relation to the concentration of a certain species in solution. Techniques which can be included under this general heading are (i) voltammetry (measurement of current at a micro-electrode at a specified voltage) (ii) coulometry (measurement of current and time needed to complete an electrochemical reaction or to generate sufficient material to react completely with a specified reagent) (iii) potentiometry (measurement of the potential of an electrode in equilibrium with an ion to be determined) (iv) conductimetry (measurement of the electrical conductivity of a solution). [Pg.7]

This procedure of using a single measurement of electrode potential to determine the concentration of an ionic species in solution is referred to as direct potentiometry. The electrode whose potential is dependent upon the concentration of the ion to be determined is termed the indicator electrode, and when, as in the case above, the ion to be determined is directly involved in the electrode reaction, we are said to be dealing with an electrode of the first kind . [Pg.548]

In the Nernst equation the term RT/nF involves known constants, and introducing the factor for converting natural logarithms to logarithms to base 10, the term has a value at a temperature of 25 °C of 0.0591 V when n is equal to 1. Hence, for an ion M+, a ten-fold change in ionic activity will alter the electrode potential by about 60 millivolts, whilst for an ion M2 +, a similar change in activity will alter the electrode potential by approximately 30 millivolts, and it follows that to achieve an accuracy of 1 per cent in the value determined for the ionic concentration by direct potentiometry, the electrode potential must be capable of measurement to within 0.26 mV for the ion M+, and to within 0.13 mV for the ion M2 +. ... [Pg.549]

In view of the problems referred to above in connection with direct potentiometry, much attention has been directed to the procedure of potentio-metric titration as an analytical method. As the name implies, it is a titrimetric procedure in which potentiometric measurements are carried out in order to fix the end point. In this procedure we are concerned with changes in electrode potential rather than in an accurate value for the electrode potential with a given solution, and under these circumstances the effect of the liquid junction potential may be ignored. In such a titration, the change in cell e.m.f. occurs most rapidly in the neighbourhood of the end point, and as will be explained later (Section 15.18), various methods can be used to ascertain the point at which the rate of potential change is at a maximum this is at the end point of the titration. [Pg.549]

Potentiometry (discussed in Chapter 5), which is of great practical importance, is a static (zero current) technique in which the information about the sample composition is obtained from measurement of the potential established across a membrane. Different types of membrane materials, possessing different ion-recognition processes, have been developed to impart high selectivity. The resulting potentiometric probes have thus been widely used for several decades for direct monitoring of ionic species such as protons or calcium, fluoride, and potassium ions in complex samples. [Pg.2]

Potential of zero charge, 20, 23, 25, 66 Potential scanning detector, 92 Potential step, 7, 42, 60 Potential window, 107, 108 Potentiometry, 2, 140 Potentiometric stripping analysis, 79 Potentiostat, 104, 105 Preconcentrating surfaces, 121 Preconcentration step, 121 Pretreatment, 110, 116 Pulsed amperometric detection, 92 Pulse voltammetry, 67... [Pg.208]

Potentiometry, which measures the open-circuit equilibrium potential of an indicator electrode, for which the substance being examined is potential determining... [Pg.387]

Potentiometry is suitabie for the analysis of substances for which electrochemical equilibrium is established at a suitable indicator electrode at zero current. According to the Nemst equation (3.31), the potential of such an electrode depends on the activities of the potential-determining substances (i.e., this method determines activities rather than concentrations). [Pg.398]

An important condition for potentiometry is high selectivity the electrode s potential shonld respond only to the snbstance being examined, not to other components in the solntion. This condition greatly restricts the possibilities of the version of potentiometry described here when metal electrodes are nsed as the indicator electrodes. The solntion shonld be free of ions of more electropositive metals and of the components of other redox systems (in particnlar, dissolved air). Only corrosion-resistant materials can be nsed as electrodes. It is not possible at all with this method to determine alkali or alkaline-earth metal ions in aqneons solntions. [Pg.399]

Potentiometric methods are based on the measurement of the potential of an electrochemical cell consisting of two electrodes immersed in a solution. Since the cell potential is measured under the condition of zero cmrent, usually with a pH/mV meter, potentiometry is an equilibrium method. One electrode, the indicator electrode, is chosen to respond to a particular species in solution whose activity or concentration is to be measured. The other electrode is a reference electrode whose half-cell potential is invariant. [Pg.3]

The indicator electrode is of paraihount importance in analytical potentiometry. This electrode should interact with the species of interest so that the potential of the... [Pg.3]

A significant development in the methodology of potentiometry that paved the way for its utility in bioanalysis was the discovery of the ion selective electrode (ISE). Conceptually, the ISE involves the measurement of a membrane potential. The response of the electrochemical cell is therefore based on an interaction between the membrane and the analyte that alters the potential across the membrane. The selectivity of the potential response to the analyte depends on the specificity of the membrane interaction for the analyte. [Pg.4]

In measurements of conductivity, no electrochemical reactions occur. Differences in conductivity are due to differences in the ionic strengths of solutions. An alternating potential is applied to the solution at a known potential. The current is measured and the conductivity in Siemens/cm calculated.16 In potentiometry, the analyte is presumed to undergo no electrochemical reaction. The potential at the electrode changes due to changes in potential across the surface of the membrane in a membrane electrode or at the electrode surface of a solid electrode. The most familiar example of a potentiometric electrode is the pH electrode. In amperometry, current does flow, due to reduction or oxidation of the substance being analyzed. [Pg.219]

Potentiometry is the measurement of the potential at an electrode or membrane electrode, so the detector response is in units of volts. The potentio-metric response tends to be slow, so potentiometry is used infrequently in analysis.47 One example is the use of a polymeric membrane impregnated with ionophores for the selective detection of potassium, sodium, ammonium, and calcium 48 In process chromatography, potentiometry may be used to monitor selected ions or pH as these values change over the course of the gradient. [Pg.220]

Principles and Characteristics A substantial percentage of chemical analyses are based on electrochemistry, although this is less evident for polymer/additive analysis. In its application to analytical chemistry, electrochemistry involves the measurement of some electrical property in relation to the concentration of a particular chemical species. The electrical properties that are most commonly measured are potential or voltage, current, resistance or conductance charge or capacity, or combinations of these. Often, a material conversion is involved and therefore so are separation processes, which take place when electrons participate on the surface of electrodes, such as in polarography. Electrochemical analysis also comprises currentless methods, such as potentiometry, including the use of ion-selective electrodes. [Pg.666]

Analytical methods based upon oxidation/reduction reactions include oxidation/reduction titrimetry, potentiometry, coulometry, electrogravimetry and voltammetry. Faradaic oxidation/reduction equilibria are conveniently studied by measuring the potentials of electrochemical cells in which the two half-reactions making up the equilibrium are participants. Electrochemical cells, which are galvanic or electrolytic, reversible or irreversible, consist of two conductors called electrodes, each of which is immersed in an electrolyte solution. In most of the cells, the two electrodes are different and must be separated (by a salt bridge) to avoid direct reaction between the reactants. [Pg.666]

Most measurements include the determination of ions in aqueous solution, but electrodes that employ selective membranes also allow the determination of molecules. The sensitivity is high for certain ions. When specificity causes a problem, more precise complexometric or titri-metric measurements must replace direct potentiometry. According to the Nernst equation, the measured potential difference is a measure of the activity (rather than concentration) of certain ions. Since the concentration is related to the activity through an appropriate activity coefficient, calibration of the electrode with known solution(s) should be carried out under conditions of reasonable agreement of ionic strengths. For quantitation, the standard addition method is used. [Pg.668]

One of the most fruitful uses of potentiometry in analytical chemistry is its application to titrimetry. Prior to this application, most titrations were carried out using colour-change indicators to signal the titration endpoint. A potentiometric titration (or indirect potentiometry) involves measurement of the potential of a suitable indicator electrode as a function of titrant volume. The information provided by a potentiometric titration is not the same as that obtained from a direct potentiometric measurement. As pointed out by Dick [473], there are advantages to potentiometric titration over direct potentiometry, despite the fact that the two techniques very often use the same type of electrodes. Potentiometric titrations provide data that are more reliable than data from titrations that use chemical indicators, but potentiometric titrations are more time-consuming. [Pg.668]


See other pages where Potentiometry potential is mentioned: [Pg.395]    [Pg.55]    [Pg.55]    [Pg.153]    [Pg.573]    [Pg.140]    [Pg.96]    [Pg.195]    [Pg.399]    [Pg.399]    [Pg.57]    [Pg.744]    [Pg.745]    [Pg.272]    [Pg.668]    [Pg.669]    [Pg.673]   