Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Micro-Electrodes

Mercury him electrode Micro-total analytical system Molecularly imprinted polymer Multiple linear regression Multiwall carbon nanotube Collection efficiency Number of electrons transferred Normal pulse... [Pg.262]

Keywords polymer electrolyte membrane fuel cell (PEMFC), porous silicon, silicon electrodes, micro fuel cells. [Pg.765]

Ribeiro, J. and De Andrade, A. R. (2004), Characterization of Ru02-Ta205 coated titanium electrode micro structure, morphology, and electrochemical investigation. J. Electrochem. Soc., 151(10) D106-D112. [Pg.95]

However, due to the transport limitation the concentration of the chemical species at the TPB is different from that in the fuel and oxidizer channels. The concentration overpotential strongly depends on electrode micro-structure. A high tortuosity and low porosity can lead to high concentration overpotentials. [Pg.50]

Electrode micro-modeling, based on analysis of transport phenomena, locahy accounting for voltage losses by means of semiempirical kinetic relationships. [Pg.76]

Directed electrochemical Electrode-wire-electrode Micro-Znanowires with PPY, PANI, and PEDOT... [Pg.36]

An elimination of iR-drop is still challenging. This starts with electrode (microelectrodes) and cell design (position of electrodes, electrolyte conductivity). Electronic positive feedback and post-factum deconvolution of amplifier limits are necessary and allow in special systems sweep rates up to 10 V/s. A universal setup for random electrodes (micro and macro, technical electrodes) and random systems (layer formation and removal, gas reactions, porous systems, electrolytes of low conductivity, extreme currents, etc.) with complete elimination of iR-drop is still missing. [Pg.1147]

Methods for iodine deterrnination in foods using colorimetry (95,96), ion-selective electrodes (94,97), micro acid digestion methods (98), and gas chromatography (99) suffer some limitations such as potential interferences, possibHity of contamination, and loss during analysis. More recendy neutron activation analysis, which is probably the most sensitive analytical technique for determining iodine, has also been used (100—102). [Pg.364]

The potentiometric micro detection of all aminophenol isomers can be done by titration in two-phase chloroform-water medium (100), or by reaction with iodates or periodates, and the back-titration of excess unreacted compound using a silver amalgam and SCE electrode combination (101). Microamounts of 2-aminophenol can be detected by potentiometric titration with cupric ions using a copper-ion-selective electrode the 3- and... [Pg.312]

The hardness of carbides can only be deterrnined by micro methods because of britdeness, the usual macro tests caimot be used. Neither can the extremely high melting points of the carbides be readily deterrnined by the usual methods. In the so-called Priani hole method, a small hoUow rod is placed between two electrodes and heated by direct current until a Hquid drop appears in the cavity. The temperature is determined pyrometricaHy. When high temperature tungsten tube furnaces are used, the melting point can readily be estimated by the Seger-type cone method. The sample may also be fused in a KroU arc furnace and the solidification temperature determined. [Pg.455]

For smart cards, micro-robots and small precision instruments, thin laminated micro-cells are being developed. Some of these developmental thin-film devices—using an electrolyte of lithium, a copper cathode, and lithium again for the electrode—can charge and discharge up to 3 volts, and can be expected to tolerate up to 1,000 charge-and-discharge cycles. [Pg.120]

In seawater, lead anodes with 1 or 2% silver may be used for cathodic protection of ships " at current densities of up to 120Am Lead with 6Vo antimony and 1 Vo silver has also been recommended. It is thought that silver might provide small stable nucleation sites for PbOj formation " in a manner similar to the Pb/Pt bi-electrode " (see Section 11.3), which is serviceable at 250 A m . A lead. Wo Ag, 0.5% Bi or 0.5% Te alloy with a platinum micro-electrode will perform well at 500 A m. ... [Pg.735]

Electrical methods of analysis (apart from electrogravimetry referred to above) involve the measurement of current, voltage or resistance in relation to the concentration of a certain species in solution. Techniques which can be included under this general heading are (i) voltammetry (measurement of current at a micro-electrode at a specified voltage) (ii) coulometry (measurement of current and time needed to complete an electrochemical reaction or to generate sufficient material to react completely with a specified reagent) (iii) potentiometry (measurement of the potential of an electrode in equilibrium with an ion to be determined) (iv) conductimetry (measurement of the electrical conductivity of a solution). [Pg.7]

The basic apparatus for polarographic analysis is depicted in Fig. 16.1. The dropping mercury electrode is here shown as the cathode (its most common function) it is sometimes referred to as the working or micro-electrode. The... [Pg.592]

The underlying theory may be simplified as follows. Polarography is concerned with electrode reactions at the indicator or micro-electrode, i.e. with reactions involving a transfer of electrons between the electrode and the components of the solution. These components are called oxidants when they can accept electrons, and reductants when they can lose electrons. The electrode is a cathode when a reduction can take place at its surface, and an anode when oxidation occurs at its surface. During the reduction of an oxidant at the cathode, electrons leave the electrode with the formation of an equivalent amount of the reductant in solution ... [Pg.599]

The polarographic determination of metal ions such as Al3 + which are readily hydrolysed can present problems in aqueous solution, but these can often be overcome by the use of non-aqueous solvents. Typical non-aqueous solvents, with appropriate supporting electrolytes shown in parentheses, include acetic acid (CH3C02Na), acetonitrile (LiC104), dimethylformamide (tetrabutyl-ammonium perchlorate), methanol (KCN or KOH), and pyridine (tetraethyl-ammonium perchlorate), In these media a platinum micro-electrode is employed in place of the dropping mercury electrode. [Pg.614]

Procedure. Place 25.0 mL of the thiosulphate solution in the titration cell. Set the applied voltage to zero with respect to the S.C.E. after connecting the rotating platinum micro-electrode to the polarising unit. Adjust the range of the micro-ammeter. Titrate with the standard 0.005 M iodine solution in the usual manner. [Pg.633]

Dilute solutions of antimony(III) and arsenic(III) (ca 0.0005M) may be titrated with standard 0.002 M potassium bromate in a supporting electrolyte of 1M hydrochloric acid containing 0.05 M potassium bromide. The two electrodes are a rotating platinum micro-electrode and an S.C.E. the former is polarised to +0.2 volt. A reversed L-type of titration graph is obtained. [Pg.634]


See other pages where Micro-Electrodes is mentioned: [Pg.613]    [Pg.49]    [Pg.297]    [Pg.126]    [Pg.373]    [Pg.15]    [Pg.227]    [Pg.380]    [Pg.114]    [Pg.109]    [Pg.764]    [Pg.152]    [Pg.613]    [Pg.49]    [Pg.297]    [Pg.126]    [Pg.373]    [Pg.15]    [Pg.227]    [Pg.380]    [Pg.114]    [Pg.109]    [Pg.764]    [Pg.152]    [Pg.1939]    [Pg.1942]    [Pg.113]    [Pg.103]    [Pg.52]    [Pg.92]    [Pg.123]    [Pg.56]    [Pg.1010]    [Pg.221]    [Pg.225]    [Pg.593]    [Pg.594]    [Pg.594]    [Pg.594]    [Pg.601]    [Pg.603]    [Pg.626]    [Pg.632]    [Pg.632]   
See also in sourсe #XX -- [ Pg.25 , Pg.29 , Pg.38 ]

See also in sourсe #XX -- [ Pg.41 , Pg.44 , Pg.47 ]

See also in sourсe #XX -- [ Pg.362 , Pg.368 ]

See also in sourсe #XX -- [ Pg.22 , Pg.47 , Pg.104 , Pg.119 , Pg.148 , Pg.169 , Pg.252 , Pg.253 , Pg.312 ]

See also in sourсe #XX -- [ Pg.25 , Pg.29 , Pg.38 ]




SEARCH



14 Faraday Micro-electrodes

A Review of Non-Cottrellian Diffusion Towards Micro- and Nano-Structured Electrodes

Changing the Electrode Geometry Macro to Micro

Complete micro-reference electrode

Electrode carbon-fiber micro

Electrode micro structured

Electrode ring micro

Electrodes photoresist micro

Membrane electrode assembly Micro

Micro carbon paste electrode

Micro electrode techniques

Micro-strip electrode

Reconstruction of PEM fuel cell electrodes with micro- and nano-structures

© 2024 chempedia.info