Polarity, in reversed-phase

There are two commonly used ways to elute a given compound in HPLC the normal-phase mode (t)s><5m) and the reversed-phase mode (<5m><5s). Reversed-phase systems offer superior general selectivity. Solutes are eluted in ascending order of polarity in normal-phase systems and in descending order of polarity in reversed-phase systems. [Pg.540]

The term polarity refers to the ability of a sample or solvent molecule to interact by combination of dispersion, dipole, hydrogen bonding, and dielectric interactions (see Chapter 2 in reference 5). The combination of these four intermolecular attractive forces constitutes the solvent polarity, which is a measure of the strength of the solvent. Solvent strength increases with polarity in normal phase, and adsorption HPLC decreases with polarity in reversed-phase HPLC. Thus, polar solvents preferentially attract and dissolve polar solute molecules. [Pg.552]

Elution in reversed-phase chromatography is often carried out using a gradient, produced from water and some water-miscible organic solvent. The solute components are thus distributed between the stationary and mobile phases mainly on the basis of their polarities. In reversed-phase chromatography hydrophilic compounds elute before hydrophobic ones. [Pg.185]

Adsorption chromatography The process can be considered as a competition between the solute and solvent molecules for adsorption sites on the solid surface of adsorbent to effect separation. In normal phase or liquid-solid chromatography, relatively nonpolar organic eluents are used with the polar adsorbent to separate solutes in order of increasing polarity. In reverse-phase chromatography, solute retention is mainly due to hydrophobic interactions between the solutes and the hydrophobic surface of adsorbent. Polar mobile phase is used to elute solutes in order of decreasing polarity. [Pg.81]

In reverse-phase chromatography, which is the more commonly encountered form of HPLC, the stationary phase is nonpolar and the mobile phase is polar. The most common nonpolar stationary phases use an organochlorosilane for which the R group is an -octyl (Cg) or -octyldecyl (Cig) hydrocarbon chain. Most reverse-phase separations are carried out using a buffered aqueous solution as a polar mobile phase. Because the silica substrate is subject to hydrolysis in basic solutions, the pH of the mobile phase must be less than 7.5. [Pg.580]

One potential problem associated with column coupling in reversed phase is relatively high back-pressure ( 2600 psi at 1 mL miir ). This will place a limit on the flow rate, which in turn limits the further reduction of analysis time. Also, compared to the new polar organic mode, the retention in reversed phase on coupled columns is deviated more from the average retention on the individual stationary phases. [Pg.40]

This is because the increased turbulence from higher flow rates decreases the possibility for inclusion complexation, a necessary event for chiral recognition in reversed phase. Some effect has also been observed in the new polar organic mode when (capacity factor) is small (< 1). Flow rate has no effect on selectivity in the typic normal-phase system, even at flow rates up to 3 inL miir (see Fig. 2-11). [Pg.45]

To retain solutes selectively by dispersive interactions, the stationary phase must contain no polar or ionic substances, but only hydrocarbon-type materials such as the reverse-bonded phases, now so popular in LC. Reiterating the previous argument, to ensure that dispersive selectivity dominates in the stationary phase, and dispersive interactions in the mobile phase are minimized, the mobile phase must now be strongly polar. Hence the use of methanol-water and acetonitrile-water mixtures as mobile phases in reverse-phase chromatography systems. An example of the separation of some antimicrobial agents on Partisil ODS 3, particle diameter 5p is shown in figure 5. [Pg.28]

Solvent strength determines the value, but not the selectivity. The mobile phase can be established by using the polarity index P proposed by Snyder. The highest values of P represent the strongest solute adsorbed in conventional TLC but represent the weakest for the separation in reversed phases. Sometimes aqueous polar mixtures cannot totally wet the chemically bonded layer. For this reason, checking... [Pg.86]

Solvatochromic pareuaeters, so called because they were Initially derived from solvent effects on UV/visible spectra, have been applied subsequently with success to a wide variety of solvent-dependent phenomena and have demonstrated good predictive ability. The B jo) scale of solvent polarity is based on the position of the intermolecular charge transfer absorption band of Reichardt s betaine dye [506]. Et(io> values are available for over 200 common solvents and have been used by Dorsey and co-%rarkers to study solvent interactions in reversed-phase liquid chromatography (section 4.5.4) [305,306]. For hydrogen-bonding solvents the... [Pg.748]

Jandera, P., Correlation of retention and selectivity of separation in reversed-phase high-performance liquid chromatography with interaction indices and with lipophilic and polar structural indices, J. Chromatogr. A, 656, 437, 1993. [Pg.191]

Jt is not possible to bond all of the surface silanol groups. Unreacted silanols are capable of adsorbing polar molecules, and will thus affect the chromatographic properties of the bonded phase. Usually, the unreacted silanols produce undesirable effects, such as tailing and excessive retention in reverse phase separations, although there have been cases reported where the unreacted silanols improve such... [Pg.95]

Kobayashi, H., Kajiwara, W., Inui, Y., Hara, T., Hosoya, K., Ikegami, T., Tanaka, N. (2004). Chromatographic properties of monolithic silica capillary columns for polar and nonpolar compounds in reversed-phase HPLC. Chromatographia 60, S19-S25. [Pg.173]

Tanaka, N., Goodeh, H., Karger, B.L. (1978). The role of organic modifiers on polar group selectivity in reversed-phase hquid chromatography. J. Chromatogr. 158, 233-248. [Pg.175]

Because plasma and urine are both aqueous matrixes, reverse-phase or polar organic mode enantiomeric separations are usually preferred as these approaches usually requires less elaborate sample preparation. Protein-, cyclodextrin-, and macrocyclic glycopeptide-based chiral stationary phases are the most commonly employed CSPs in the reverse phase mode. Also reverse phase and polar organic mode are more compatible mobile phases for mass spectrometers using electrospray ionization. Normal phase enantiomeric separations require more sample preparation (usually with at least one evaporation-to-dryness step). Therefore, normal phase CSPs are only used when a satisfactory enantiomeric separation cannot be obtained in reverse phase or polar organic mode. [Pg.328]

Solvatochromic probes have been used for a variety of applications like the study polarity of pure and mixed solvents [99], and the retention behavior in reverse-phase liquid chromatography [100] among other applications. Frechet et al. used 4-(N-methylamino)-l-nitrobenzene (p-MANB), as the chromophore, to probe the microenvironment of polyaromatic ether based dendrimers [101]. [Pg.49]

Specific separation effects can be understood from the multicomponent solubility parameter theory. Specific effects for nonpolar compounds are predictable with perfluorinated and graphitized carbon black stationary phases. Specific selectivity for polar compounds in reversed-phase HPLC can be realized with polar additives to the mobile phase. [Pg.541]

In reverse phase chromatography, the polar mixture components would elute first since they would be attracted by the polar mobile phase and repelled by the nonpolar stationary phase. In normal phase chromatography, nonpolar mixture components would elute first since they would be attracted by the nonpolar mobile phase and repelled by the polar stationary phase. [Pg.538]

In recent years, also the number of articles concerning HILIC stationary phases has enormously increased, especially as regards the hydrophilic interactions that resolve some important problems separation and resolution of less retained compound in reversed phase chromatography. With this novel stationary phase, where the silica surface is covered with cross-linked diol groups to increase polar selectivity in hydrophilic conditions, is possible obviate to the use of normal phase with high water content. This allows facilitating the interfacing with sensible and selective detection instruments, such as mass spectrometer with ESI source. The HILIC stationary phase was often chosen to interface the mass spectrometry detector, because it would be... [Pg.54]


See other pages where Polarity, in reversed-phase is mentioned: [Pg.585]    [Pg.208]    [Pg.36]    [Pg.90]    [Pg.585]    [Pg.208]    [Pg.36]    [Pg.90]    [Pg.157]    [Pg.157]    [Pg.30]    [Pg.40]    [Pg.217]    [Pg.305]    [Pg.308]    [Pg.312]    [Pg.154]    [Pg.247]    [Pg.44]    [Pg.54]    [Pg.98]    [Pg.99]    [Pg.133]    [Pg.133]    [Pg.200]    [Pg.225]    [Pg.374]    [Pg.518]    [Pg.519]    [Pg.555]    [Pg.9]    [Pg.1086]   