Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Tubing plastic

After the addition of the propyne the thermometer-gas outlet combination was replaced with a "cold finger" filled with dry-ice and acetone. The top of this reflux condenser was connected via a plastic tube with a cold trap (-75°C) containing 50 ml of dry THF. The cooling bath was removed and the conversion of propyne started... [Pg.71]

Appanztus 5-1 round-bottomed, wide-necked flask with a mechanical stirrer for the preparation of CH3CEC-SCH3 2-1 round-bottomed flask and a rubber stopper, perforated by a glass tube, internal diameter 4-5 mm the glass tube, when placed on the flask, reached nearly to the bottom of the flask the upper end of the glass tube was connected to a plastic tube. [Pg.107]

A suspension of 0.40 mol of sodium amide in 300 ml of liquid ammonia was prepared as described in Chapter II, Exp. 11. To the suspension was added with swirling a mixture of 0.25 mol of CHgCeC-S-Ph (see Chapter IV, Exp. 14) and 40 ml of THE in about 2 min (note 1). Swirling was continued after the addition. Three minutes later (note 1) the stopper with glass tube was placed on the flask. The brown solution was forced through the glass tube and the plastic tube, connected to it under 400 g of finely crushed ice, which was contained in a 3-1 conical flask (see Chapter I, Fig. 3, and accompanying description of this operation). The flask was placed for... [Pg.110]

Apparatus See Fig. 7 size of the flask, 2 1 a gas-tight stirrer should be used the top of the condenser was connected uia a plastic tube to 2 tubes filled with lumps of CaCl2- These tubes in turn were connected to 2 cold traps (-80°C) each of which contained 40 ml THF or CH3OCH2CH2OCH3 (free from peroxides). [Pg.146]

P/astic. Plastic tubing is used for farm-to-receiving operations rather than for permanent food handling installations. It is widely used to transport water for cleaning and sanitizing. [Pg.361]

Fig. 6. Extrusion of blown film A, blown-film die B, die inlet C, air hole and valve D, plastic tube (bubble) E, air ring for cooling E, guide roUs G,... Fig. 6. Extrusion of blown film A, blown-film die B, die inlet C, air hole and valve D, plastic tube (bubble) E, air ring for cooling E, guide roUs G,...
Plastic tubing is widely used for instrument air-signal connec tions. [Pg.979]

Eliminate sources of fuel Blank unused lines at switching station Provide emergency cooling activated by external fire (e.g., fusible link, plastic tubing)... [Pg.59]

In the cathodic protection of storage tanks, potentials should be measured in at least three places, i.e., at each end and at the top of the cover [16]. Widely different polarized areas arise due to the small distance which is normally the case between the impressed current anodes and the tank. Since such tanks are often buried under asphalt, it is recommended that permanent reference electrodes or fixed measuring points (plastic tubes under valve boxes) be installed. These should be located in areas not easily accessible to the cathodic protection current, for example between two tanks or between the tank wall and foundations. Since storage tanks usually have several anodes located near the tank, equalizing currents can flow between the differently loaded anodes on switching off the protection system and thus falsify the potential measurement. In such cases the anodes should be separated. [Pg.100]

Anode supports, cable insulators and the coating on the object to be protected can be destroyed by anodic evolution of chlorine (see Section 7.1), Only chorine-resistant materials should be used. Anodes on retaining walls or between pile foundations can be installed in perforated or fabricated plastic tubes (half-shells) (see Fig. 16-8). They must naturally be provided with very many holes to avoid uneven removal of anode material. Filter tubes of a chlorine-resistant special material or... [Pg.378]

In principle, the velocities c and ti can be determined by taking a series of pictures at a very high frequency of the flow through a transparent plastic tube. Because of the particle size distribution, each particle moves at a different velocity, and this makes this method difficult to apply in practice. We have therefore used an indirect method, where we have measured the pressure losses of pneumatic conveying for two mixture ratios and then fit the parameters so that Eq, (14.126) coincides as accurately as possible with measured pressure losses. [Pg.1350]

Piezometer tube An open-ended calibrated glass or plastic tube that measures the pressure in a pipe or vessel full of a fluid. [Pg.1466]

Minimum energy required for piloted ignition of wood, melting of plastic tubing... [Pg.180]

One method that can be used to overcome most of the environment-induced problems is to use plastic tubing to shield the beam. This tubing can be placed between the transmitter and receiver of the optical-alignment fixture. It should be sized to permit transmission and reception of the light beam, but small enough to prevent distortion caused by atmospheric or environmental conditions. Typically, 2-inch, thin-wall tubing provides the protection required for most applications. [Pg.924]

The principle reference electrodes used in the onshore and offshore industries have remained unchanged. The CU/CUSO4 cell is used almost exclusively onshore in the form based on the plastic tube and porous wooden plug illustrated in Fig. 10.40, although certain potential survey instruments have... [Pg.256]

The chassis is made from a 1/4 in. sheet of either ABS or TPO vacuum formed into a tub and reinforced with reinforced pultruded glass fiber-TS polyester plastic tubing. The hood and other products are being made from a 20 mm thick sandwich of thermo-formed PPO-alloy skins, glass fabric infused with thermosetting vinyl ester, and a urethane foam core. The bumper and front fascia is thermoformed from a polyolefin elastomer sheet with an UV-resistant cap layer of DuPont s Tediar PVF film. The dash and... [Pg.254]

While it would be difficult to enumerate all of the efforts in the area of implants where plastics are involved, some of the significant ones are (1) the implanted pacemaker, (2) the surgical prosthesis devices to replace lost limbs, (3) the use of plastic tubing to support damaged blood vessels, and (4) the work with the portable artificial kidney. The kidney application illustrates an area where more than the mechanical characteristics of the plastics are used. The kidney machine consists of large areas of a semi-permeable membrane, a cellulosic material in some machines, where the kidney toxins are removed from the body fluids by dialysis based on the semi-permeable characteristics of the plastic membrane. A number of other plastics are continually under study for use in this area, but the basic unit is a device to circulate the body fluid through the dialysis device to separate toxic substances from the blood. The mechanical aspects of the problem are minor but do involve supports for the large amount of membrane required. [Pg.259]

Fuzes and Tracers are individually wrapped in pasteboard or plastic tubing. No more than 50 of these individual packets are to be in the next OlltSf usually rnrtrm SSn ri l nrn. [Pg.479]

Desmopressin may be given orally, intranasally, SC, or IV. The oral dose must be determined for each individual patient and adjusted according to the patient s response to therapy. When the drug is administered nasally, a nasal tube is used for administration. The nasal tube delivery system comes with a flexible calibrated plastic tube called a rhinyle. The solution is drawn into the rhinyle. One end is inserted into the nostril and the patient (if condition allows) blows the other end to deposit solution deep into the nasal cavity. A nasal spray pump may also be used. Most adults require 0.2 mL daily in two divided doses to control diabetes insipidus. The drug may also be administered via the SC route or direct IV injection. [Pg.520]

When administering nasally, a nasal tube is used for administration. The nasal tube delivery system comes with a flexible calibrated plastic tube called a rhinyle... [Pg.521]


See other pages where Tubing plastic is mentioned: [Pg.1]    [Pg.108]    [Pg.110]    [Pg.111]    [Pg.229]    [Pg.480]    [Pg.19]    [Pg.274]    [Pg.305]    [Pg.296]    [Pg.479]    [Pg.979]    [Pg.1728]    [Pg.617]    [Pg.3]    [Pg.24]    [Pg.392]    [Pg.575]    [Pg.379]    [Pg.488]    [Pg.113]    [Pg.142]    [Pg.337]    [Pg.149]    [Pg.224]    [Pg.245]    [Pg.322]    [Pg.73]    [Pg.731]   
See also in sourсe #XX -- [ Pg.311 ]

See also in sourсe #XX -- [ Pg.539 ]




SEARCH



Bending tubing plastic

Debris plastic tubing

Plastic Drift Tubes

Plastic tubing crimp seals

Porous plastic tubes

Test-tube ends plastic

Tube, plastic

Tubes, Bingham plastic flowing

© 2024 chempedia.info