Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Dialysis devices

While it would be difficult to enumerate all of the efforts in the area of implants where plastics are involved, some of the significant ones are (1) the implanted pacemaker, (2) the surgical prosthesis devices to replace lost limbs, (3) the use of plastic tubing to support damaged blood vessels, and (4) the work with the portable artificial kidney. The kidney application illustrates an area where more than the mechanical characteristics of the plastics are used. The kidney machine consists of large areas of a semi-permeable membrane, a cellulosic material in some machines, where the kidney toxins are removed from the body fluids by dialysis based on the semi-permeable characteristics of the plastic membrane. A number of other plastics are continually under study for use in this area, but the basic unit is a device to circulate the body fluid through the dialysis device to separate toxic substances from the blood. The mechanical aspects of the problem are minor but do involve supports for the large amount of membrane required. [Pg.259]

When classifying chemical products, Seider et al. [3] identify three categories (1) basic chemicals (commodity and specialty chemicals, bio-materials, and polymeric materials) (2) industrial chemicals (films, fibers, paper,. ..) and (3) configured consumer products (dialysis devices, post-it notes, transparencies, drug delivery patches,. ..). In the manufacture of epitaxial silicon wafers, a thin film of crystalline silicon is often deposited on a polished crystalline silicon... [Pg.289]

Jacobson I, Sandberg M, Hamberger A. 1985. Mass transfer in brain dialysis devices-a new method for the estimation of extracellular amino acids concentration. J Neurosci Methods 15(3) 263-268. [Pg.247]

The instruments involved in this method are dynamic mixing devices with two pumps, and a cross-Low Lltration device with proper membranes (Figure 14.8). One pump is used to push the organic phase with a slow rate and the other is used to pump the aqueous phase with a fast rate Liposomes can be prepared by continuously pumping the organic phase and the aqueous phas together and then Low through the dialysis devices. [Pg.395]

A microfabricated dialysis device was used to clean up the sample (i.e., protein) by removing the matrix interference in an ESI chip before carrying out MS analysis (see Figures 5.10 and 5.11). What substances from the matrix are removed [811] (2 marks)... [Pg.399]

Xu, N., Lin, Y., Hofstadler, S.A., Matson, D., Call, C.J., Smith, R.D., A micro-fabricated dialysis device for sample cleanup in electrospray ionization mass spectrometry. Anal. Chem. 1998, 70, 3553-3556. [Pg.452]

De Lange ECM, De Boer AG, Breimer DD (2000) Methodological issues in microdialysis sampling for pharmacokinetic studies. Adv Drug Deliv Rev 45 125-148 Elmquist WF, Sawchuk RJ (1997) Application of microdialysis in pharmacokinetic studies. Pharm Res 14 267-288 Evrard PA, Deridder G, Verbeeck RK (1996) Intravenous microdialysis in the mouse and the rat development and pharmacokinetic application of a new probe. Pharm Res 13 12-17 Jacobson I, Sandberg M, Hamberger A (1985) Mass transfer in brain dialysis devices a new method for the estimation of extracellular amino acids concentration. J Neurosci Methods 15 263-268... [Pg.598]

FIGURE 25.15 Preliminary experiments on coupling separation and photodegradation (a) experimental dialysis device (b) methylene blue concentration versus time in the reception tank. P70 and F67 are two types of anatase coatings. (From Bose, F., Ayral, A., and Guizard, C., in Proceedings of the ICIM8, J. Lin, Ed., Cincinnati, OFI, 2004.)... [Pg.463]

Apparatus for studying the many variables in suppository formulation has been designed to measure rates of release in vitro. Both a circulating dissolution apparams and a dialysis device utilising an aqueous and a nonaqueous phase have been described, and are discussed in section 12.3.1. [Pg.387]

Smith and co-workers designed a microfabricated dialysis device for sample cleanup before ESI MS. A microdialysis membrane sandwiched between two chips having micromachined serpentine channels provided efficient desalting for both DNA and protein samples before subsequent ESI ion trap MS. In a continuation study, they used a fabricated dual microdialysis membrane for removing both high- and low-molecular-weight species that... [Pg.540]

Self-diffusion coefficients of polyvalent cations in these perfluorinated ionomer membranes have not been reported. It can be inferred from the use of the sulfonate membranes as Donnan dialysis devices that transport of cations such as CuflT), Mg(II), and Al(III) under a concentration gradient is rapid. Also, column chromatographic separation of the alkaline-earth ion is readily accomplished with a powdered Nafion perfluorosulfonate polymer, which is again an indication of facile diffusion of these cations within the polymer phase. [Pg.465]

Dialysis is a diffusion-based separation process that uses a semipermeable membrane to separate species by vittue of their different mobilities in the membrane. A feed solution, containing the solutes to he separated, flows ou one side of the membrane while a solvent stream, die dialysate, flows on die other side (Fig. 21. -1). Solute transport across the membrane occurs by diffusion driven by the difference in solme chemical potential between the two membrane-solution interfaces. In practical dialysis devices, no obligatory transmembrane hydraulic pressure may add an additional component of convective transport. Convective transport also may occur if one stream, usually the feed, is highly concentrated, thus giving rise to a transmembrane osmotic gradient down which solvent will flow. In such circumstances, the description of solute transport becomes more complex since it must incorporate some function of die trans-membrane fluid velocity. [Pg.954]

Fresh high-flux dialysis membranes achieve approximately 23—37% reductions in plasma P2M levels [344]. However, dialyzer reuse significantly impairs the removal of P2M [345]. Indeed, it has been recognized that non-specific adsorption of middle molecules on the surface of these synthetic high-flux membranes, rather than difiusion through the membrane, can account for significant amounts of the device s clearance [346, 347]. With the surface area of membranes in the dialysis device amounting to less than 2 m, the adsorption capacity of the device is obviously too small. [Pg.569]

Blood and solution bag, surgical packaging, IV sets, dialysis devices, catheter bottles, connectors, and cannulae... [Pg.640]

PVC sheets and films are used in blood and solution storage bags and surgical packaging. PVC tubing is commonly used in intravenous (IV) administration, dialysis devices, catheters, and cannulae. [Pg.640]

Consumer Products (Dialysis Devices, Post-it Notes, Transparencies, Drug Delivery Patches, Cosmetics,...)... [Pg.4]

Alternative 2. Design a peritoneal dialysis device (which uses the serous membrane that lines the cavity of the abdomen of a mammal) having similar attributes as the hemodialysis device. ... [Pg.10]

Large central veins (e.g. vena jugularis or vena subclavia) An infusion can also be administered subcutaneously. However the volume to be administered is limited to 20-30 mL per 24 h (see Sect. 13.10.3). During extracorporeal circulation procedures such as haemodialysis a parenteral liquid can be administered via ports in the dialysis devices. [Pg.270]

I. Derive the following equation for a counter-cuirent dialysis device in which the dialysate flow rate is high, i.e. q >qj. [Pg.509]


See other pages where Dialysis devices is mentioned: [Pg.219]    [Pg.217]    [Pg.137]    [Pg.552]    [Pg.178]    [Pg.271]    [Pg.111]    [Pg.111]    [Pg.955]    [Pg.349]    [Pg.8]    [Pg.1498]    [Pg.9]    [Pg.4]    [Pg.8]    [Pg.651]    [Pg.652]    [Pg.656]    [Pg.158]    [Pg.955]    [Pg.150]    [Pg.380]    [Pg.132]    [Pg.990]    [Pg.346]   


SEARCH



Dialysis

Dialysis device, 8, 9-10 (also

© 2024 chempedia.info