Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Optimized connection system

This connection system [20] ensures that chemicals come in contact with only silicon and Teflon . Chemicals and reagents were applied with disposable syringes [Pg.456]

With the prerequisite of safe handling of organic compounds we carried out several chemical reactions in the flow-through mode. [Pg.457]


Another study (32) maximized the efficiency of conventional and series-connected fuel cell systems by optimizing cell voltage and current density. The study found that the optimum fuel utilization in the series-connected system was higher than that in the conventional system. Most importantly, the higher fuel utilization and lower current density of the series-connected system combined to give more efficient performance than the conventional system. [Pg.272]

Figure 5.2 shows the influence of dead volume and connection design on the peak distortion and dead time of the HPLC unit. Three runs were performed with the same flow rate and sample size (injection time 2 s). The straight black line describes the elution profile of a tracer in an optimal system with small dead volume and optimal connections. In the next example one of the tube connections was insufficient because, within the connector, the tube endings did not touch and a small dead volume is formed. The dashed line shows the new elution profile. A poor connection results in higher backmixing and, thus, peak distortion. This effect should be kept in mind for systems with many connections. [Pg.174]

Optimized Micromixer with an Advanced Connection System... [Pg.458]

Once the selectivity is optimized, a system optimization can be performed to improve resolution or to minimize the separation time. Unlike selectivity optimization, system optimization is usually predictable, since only kinetic parameters are generally considered. Typical experimental variables include column length, particle size, flow rate, instrument configuration, sample injection size, etc. Many of these parameters are connected to the chromatogram through reliable equations, and therefore, computer simulation approaches have been successful in providing a stmctured approach to this problem [375,557,558]. [Pg.365]

Affordable vision replacement systems are farther into the future since much more needs to be known about how to optimally connect to the visual cortex. Since this will involve a surgical procedure, there will need to be stringent testing to ensure that there are no adverse effects. [Pg.664]

The numerous problems connected to the oxychlorination process, e.g. choosing the optimal catalyst system and grain size distribution, the selection of materials in contact with the hot, wet reaction gases containing chlorine, hydrochloric acid and solvents, removing the catalyst particles from the reaction gas and returning them to the reaction zone, removal of the produced water, recovery of unreacted ethene, have created a great variety of different technical solutions [360]. [Pg.190]

On the basis of data obtained the possibility of substrates distribution and their D-values prediction using the regressions which consider the hydrophobicity and stmcture of amines was investigated. The hydrophobicity of amines was estimated by the distribution coefficient value in the water-octanole system (Ig P). The molecular structure of aromatic amines was characterized by the first-order molecular connectivity indexes ( x)- H was shown the independent and cooperative influence of the Ig P and parameters of amines on their distribution. Evidently, this fact demonstrates the host-guest phenomenon which is inherent to the organized media. The obtained in the research data were used for optimization of the conditions of micellar-extraction preconcentrating of metal ions with amines into the NS-rich phase with the following determination by atomic-absorption method. [Pg.276]

The optimal conditions for the complexation were found. The luminescence of Tb " in (L ) complex was established to observed in a range of pH 2,0-11,0 with maximum at 7,0-7,5. The Tb (III) luminescence in complex with (L ) aslo depends on amount of reagents, solvent nature, amount of surfactants and trioctylphosphinoxide (TOPO). It was shown that introduction into the system Tb-L the 3-fold excess sodium dodecylsulfate (SDS) increases the luminescence intensity by 40 times and introduction into the system Tb-L the 3-fold excess TOPO increases the luminescence intensity by 25 times by the order value connecting with the crowding out of water molecules from the inner sphere of complexes. [Pg.394]

A typical relay is shown in Figure 12.29(b). These relays can also be made digital to be connected to a central control system for close monitoring and control of a process. Now they can have much wider application, such as better communication and information feedback facilities, to optimize a process and maximize productivity. For more details refer to Section 13.2.. ) or contact the manufacturers. [Pg.297]

The gas turbine is a complex system. A typical control system with hierarchic levels of automation is shown in Figure 19-3. The control system at the plant level consists of a D-CS system, which in many new installations is connected to a condition monitoring system and an optimization system. The D-CS system is what is considered to be a plant level system and is connected to the three machine level systems. It can, in some cases, also be connected to functional level systems such as lubrication systems and fuel handling systems. In those cases, it would give a signal of readiness from those systems to the machine level systems. The condition monitoring system... [Pg.636]

An IRC calculation examines the reaction path leading down from a transition structure on a potential energy surface. Such a calculation starts at the saddle point and follows the path in both directions from the transition state, optimizing the geometry of the molecular system at each point along the path. In this way, an IRC calculation definitively connects two minima on the potential energy surface by a path which passes through the transition state between them. [Pg.173]


See other pages where Optimized connection system is mentioned: [Pg.456]    [Pg.394]    [Pg.456]    [Pg.394]    [Pg.389]    [Pg.235]    [Pg.326]    [Pg.239]    [Pg.104]    [Pg.819]    [Pg.41]    [Pg.26]    [Pg.18]    [Pg.748]    [Pg.9]    [Pg.14]    [Pg.323]    [Pg.230]    [Pg.377]    [Pg.616]    [Pg.206]    [Pg.1]    [Pg.90]    [Pg.231]    [Pg.83]    [Pg.1404]    [Pg.16]    [Pg.123]    [Pg.93]    [Pg.83]    [Pg.502]    [Pg.755]    [Pg.1151]    [Pg.17]    [Pg.180]    [Pg.225]   
See also in sourсe #XX -- [ Pg.456 ]




SEARCH



Connection optimized

Connection system

Optimized Micromixer with an Advanced Connection System

System optimization

© 2024 chempedia.info