Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Operation of the Programme

In order that the programme can be used to calculate both the resonance frequency (RF) and angular resonance frequency (WR) for a chosen bubble (radius, br) it will be necessary to input the solvent density (d), the surface tension of the solvent (a), the solvent viscosity (q) and the solvent vapour pressure (pv). The programme can correct the data to the appropriate SI unit. For example, if a bubble radius of 10 cm was entered the correct response to the question Type in the initial (equilibrium) bubble radius in cm - line 280 - would be either 0.01 or lE-2 followed by return. The programme will convert the value to metres - (i.e. BR=.01 br). [Pg.72]

This section of the programme allows an estimation of the acoustic amplitude (P ) of the wave from knowledge of the intensity (Int) of the wave and the velocity (vel) of sound in the medium. The value for velocity must be either entered in full (i.e. 1500) or by using the mathematical notation 1.5E3. [Pg.72]

This section of the programme determines the maximum and minimum acoustic pressure and bubble radius and ensures optimum use of the screen. [Pg.72]

This section of the programme calculates and displays the variation in the applied acoustic pressure, the resonance pressure (or frequency) and the bubble dimensions with time. The GCOL statements in lines 1200 and 1220 refer to colour (e.g. GCOL0,l is red and GGOL0,3 is white). [Pg.72]

20 GOSUB1290 N=O GCOLO,3 CLS PRINT INPUT Is the solvent water. Y/N ANS  [Pg.73]


Kosmowski K.T., Sliwinski M. 2007. Risk Analysis and probabilistic modelling based on knowledge in designing and operation of the programmable control and protection systems. Gliwice Pomiary Automatyka Kontrola Vol.4 135-138. [Pg.104]

Watch dog Combination of diagnostics and an output devices meant to monitor the correct operation of the programmable electronic (PE) devices and taking action upon detection of an in correct operation. [Pg.933]

The detailed fault tree models provide useful Information about the Impact of various component failures on the overall operation of the programmable controller. However, because of their size and complexity, they are unsuitable for direct Inclusion In the fault tree models of the various process systems. It, therefore, became necessary to develop simplified fault tree models that would, nevertheless, retain the major contributors to system failure. [Pg.102]

The onus for the organisation of any inspection programme beyond that required by Class rests with the owner or operator of the ship. Under certain circumstances, for example, when the propagation of cracks could lead to pollution through the loss of cargo, an owner of an oil tanker operating in US coasted waters may spend a considerable amount of money on preventative inspections. [Pg.1046]

The experimental programme was mainly concerned with estimating kinetic parameters from isothermal steady state operation of the reactor. For these runs, the reactor was charged with the reactants, in such proportions that the mixture resulting from their complete conversion approximated the expected steady state, as far as total polymer concentrations was concerned. In order to conserve reactants, the reactor was raised to the operating temperature in batch mode. When this temperature had been attained, continuous flow operation commenced. This was... [Pg.284]

It has to be said that this is a very optimistic timetable and the author s view is that there is likely to be significant slippage in all phases but especially in the operation of the review programme. [Pg.13]

The program listing contains sufficient remark statements for the operation of the program to be easily followed. It is written in GW-BASIC for personal computers. It can easily be adapted for other forms of BASIC and for use on programmable calculators. The use of the program is illustrated in Example 3.14a. It has also been used for other examples in this chapter and in the flow-sheeting, Chapter 4. [Pg.95]

Dawson et al. [227] described samplers for large-volume collection of sea water samples for chlorinated hydrocarbon analyses. The samplers use the macroreticular absorbent Amberlite XAD-2. Operation of the towed fish type sampler causes minimal interruption to a ship s programme and allows a large area to be surveyed. The second type is a self-powered in situ pump which can be left unattended to extract large volumes of water at a fixed station. [Pg.406]

Figure 9.6 shows the stability of the lifetime-based system here described over a period of 100 h of continuous operation. The sensor was immersed in saline solution in equilibrium with air at 760 torr. The intensity of the sensor decays with time due to the photodestruction of the porphyrin molecules (photobleaching). However, the lifetime value measured by the instrument remains relatively invariant over this period with a system drift of less than 1%. The instrument adjusts the gain of the programmable amplifier to compensate for the reduction in signal. [Pg.289]

To develop a distributed modeling system, it is necessary to identify the primitive components essential to the fundamental operation of the system and its various appended and programmable functions, a process referred to as kernel identification. Studying such systems provides much of the basis for acquiring insight into what structure and function a kernel should possess (9). [Pg.269]

The manual also includes a detailed description of the structure and operating procedures of the programme and contains the criteria against which a certification programme is assessed. [Pg.43]

At the end of the selected number of sample analysis cycles, one analysis of the standard is performed. The system then either terminates work or repeats the entire sequence at the discretion of the operator. The interval between analyses is under program control and may vary from 2 min to 1 hr. A provision for making standard additions under program control has also been made, but as of this writing the automated pipette has not been installed, and standard additions were made with a handheld micropipette. Details of the programmer system and wiring diagrams are available upon request. [Pg.84]

Many of the controls are sequential and on-off thus, the control philosophy is particularly amenable to PLC (Programmable Logic Controller), PC (Personal Computer), or Distributive Microprocessor Controls. Proportioning controls can be easily incorporated into such a system. A Graphic Panel Display with digital indicating and recording modes will add clarity for the operators of the plant. [Pg.534]


See other pages where Operation of the Programme is mentioned: [Pg.72]    [Pg.40]    [Pg.50]    [Pg.72]    [Pg.40]    [Pg.50]    [Pg.361]    [Pg.392]    [Pg.260]    [Pg.146]    [Pg.215]    [Pg.4]    [Pg.11]    [Pg.213]    [Pg.39]    [Pg.259]    [Pg.104]    [Pg.2252]    [Pg.54]    [Pg.74]    [Pg.116]    [Pg.341]    [Pg.78]    [Pg.94]    [Pg.38]    [Pg.126]    [Pg.160]    [Pg.53]    [Pg.53]    [Pg.45]    [Pg.559]    [Pg.380]    [Pg.381]    [Pg.426]    [Pg.179]    [Pg.198]    [Pg.543]    [Pg.38]    [Pg.36]   


SEARCH



Co-operative Programme for Monitoring and Evaluation of the Long-Range

© 2024 chempedia.info