Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Offline

To evaluate the VIGRAL method, we scanned steel blocks with simulated flaws using a Flexilrak and a upi-50 instrument. This system allows for rapid and accurate acquisition of the desired data, including the A-scan, B-scan, and C-scan data, and serves to evaluate, offline, the V-scan image (Figure 8). [Pg.168]

Membrane extraetion ean easily be set up in flow systems and ean be eonneeted in an automated way on-line to various analytieal instmments. Also, offline eheap hollow-fiber systems are available. High degrees of elean up and enriehment ai e obtained, whieh is very important for reliable and sensitive ehemieal analysis. Reeent applieations of automated detenuination of PCB and phenols will be presented. [Pg.244]

A larger unit may have a lower eapaeity faetor and may be required to go offline at a higher minimum output. This eould result in less energy produetion than a smaller unit that may operate at 100% load... [Pg.478]

Raghaven, K. V. (1992). Temperature Runaway in Fixed Bed Reactors Online and Offline Checks for Intrinsic Safety. Journal of Loss Prevention in the Process Industries 5, 3,153-59. [Pg.144]

Offline" discussions between members, by phone or in person, can be encouraged. [Pg.71]

With this method, levels of 0.1 p.g 1 can be detected in ground water and, if an offline liquid-liquid extraction step is added, levels of 0.1 p.g 1 can be detected (48). [Pg.346]

For continuous operation, the filter must be constructed with multiple compartments. This is necessary so that individual compartments can be sequentially taken offline for cleaning while the other compartments continue to operate. [Pg.777]

Where a complex system is served by two or more condensers, a complete condenser can be taken offline by a pressure switch. [Pg.79]

NOTE Water tube boiler water-wall headers should not be blown down while the boiler is under load because it disturbs the natural circulation and may result in an overheated and bulging or ruptured tube. Usually header blowdown valves are locked closed and are only blown down when the boiler goes offline. [Pg.74]

Boiler plant operational duties occasionally necessitate starting up boilers from cold (cold plant startups or dead plant startups), bringing a boiler online to support other operational boilers (live plant startups), and taking boilers offline. [Pg.120]

The operational duties of these smaller boiler systems vary widely, and for HW closed-loop heating systems, where the boiler is periodically offline, or in indirect heating systems where pipework, valves, or final heating units are exposed to chilly winds or icy conditions, some boiler winterization may be necessary. This is usually provided by replacing some of the water with glycols or other heat transfer fluids. [Pg.177]

As the lead boiler generates steam, the condensate falls back into an idle or offline boiler because of inadequate valving. Excessive MU is supplied to the lead boiler and the TDS quickly rises to exceed control parameters, while the lag boiler steam space (and possibly some of the steam header) fills up with condensate, diluting any chemical inhibitor present below the minimum protective inhibitor reserve level. [Pg.185]

Boilers may need to be taken offline immediately and boiled out, or at the least blown down very heavily for some period to remove the contaminants. [Pg.204]

As a consequence, when a boiler is taken offline (because of pitting corrosion, tube leaks, or some other problem), it is vitally important to understand the chain of cause and effect and to ensure that the correct remedy or work protocol is in place before putting the boiler back in service. [Pg.238]

Although relatively uncommon, low BW pH may occur for a variety of reasons under online operating conditions, resulting in either general or localized low pH corrosion. Under offline conditions, low pH corrosion usually is simply a result of improper acid cleaning procedures. [Pg.251]

NOTE EDTA, NTA, and other chelants are also employed in various online and offline boiler plant cleaning formulations. [Pg.262]

Insurance inspections and cleaning programs further add to the frequency at which a boiler may be out of service. During these outages and offline periods, the boiler metal waterside surfaces are especially susceptible to rapid corrosive attack and damage. Consequently, various protection protocols are employed to stave off this risk. The primary factors responsible for downtime corrosion are ... [Pg.606]

Protection of Standby Boilers (Short-Term Offline)... [Pg.606]

Where the offline period is prolonged, the boiler may be stored using... [Pg.608]

For boilers coming offline, flooding should take place as the unit cools but before the pressure drops to zero. [Pg.608]

Heavy industrial boilers operating in continuous processes may be online for perhaps four or even five years before shutting down for maintenance and inspection. Here, correct boiler plant materials selection is critical, and the quality of the various utility support functions must be outstanding if forced outages are to be avoided. A heavy industrial or utility boiler that is unintentionally offline may cost 1 million a day in lost production or electricity generation. [Pg.612]

To obtain a clear picture of larger, more complex, offline WT boilers, in addition to visual inspections, it is common practice to trepan or cut sections out of some of the tubes. The deposits found are weighed, reported as a weight per unit surface area, and analyzed. Repairs are then made to the tubes. [Pg.622]

Offline cleaning can, and should, be entirely successful, with the simplest methods requiring, say, a 10 or 15% inhibited hydrochloric (muriatic) acid solution that is allowed to soak for some hours before neutralization, flushing, and refilling. Where the waterside deposit analysis reveals complex scales, however, it may be necessary to employ several different cleaning solvents. These solvents are added in a multistep process. [Pg.629]

Cleaning a boiler offline is unlike online cleaning. Ensuring operator safety is essential because the process generally involves using potentially dangerous acids, sometimes at temperatures of 200 to 300 °F. [Pg.630]

Where equipment has been in operational use for some length of time (say, several years), and despite the use of appropriate internal and external water treatment programs, it may become necessary to provide some form of basic offline cleaning to restore heat-transfer efficiency. For smaller HW and LP steam FT boilers, especially where external water treatment is minimal and internal water treatment is limited by cost considerations, the frequency of offline cleaning may be annual, perhaps at the end of the winter heating season. [Pg.652]

In practice, PCC programs and basic offline cleaning programs are virtually the same. Both types of program rely on providing an alkaline boil-out. [Pg.652]

A type of valve located in the steam line and elsewhere that automatically cuts the boiler in and out, thus providing for online and offline operation. This valve protects the steam system in the event of a loss of pressure from a boiler, caused perhaps by a large steam leak. [Pg.715]


See other pages where Offline is mentioned: [Pg.309]    [Pg.484]    [Pg.55]    [Pg.76]    [Pg.262]    [Pg.1603]    [Pg.514]    [Pg.528]    [Pg.435]    [Pg.511]    [Pg.42]    [Pg.171]    [Pg.237]    [Pg.508]    [Pg.601]    [Pg.607]    [Pg.607]    [Pg.625]    [Pg.626]    [Pg.629]    [Pg.630]    [Pg.675]    [Pg.814]   
See also in sourсe #XX -- [ Pg.487 ]




SEARCH



Compressors offline cleaning

Lexicons offline lexicon

Offline Measurements

Offline Selection

Offline Technique

Offline Winding

Offline analysis

Offline analysis techniques

Offline analytics

Offline and Online Usage

Offline conductivity

Offline definition

Offline interfacing

Offline lexicon

Offline methods

Offline print

Offline query formulation

Offline radionuclide detection

Offline-ADAS

Sensor offline

Solid-phase extraction offline

Solid-phase extraction, with offline

The offline lexicon

© 2026 chempedia.info