Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Non screening

It is worthwhile to mention the ample use of screening final states models in understanding core levels as well as valence band spectra of the oxides. The two-hole models, for instance, which have been described here, are certainly of relevance. Interpretational difference exists, for instance, on the attribution of the 10 eV valence band peak (encountered in other actinide dioxides as well), whether due to the non-screened 5f final state, or to a 2p-type characteristics of the ligand, or simply to surface stoichiometry effects. Although resonance experiments seem to exclude the first interpretation, it remains a question as to what extent a resonance behaviour other than expected within an atomic picture is exhibited by a 5 f contribution in the valence band region, and to what extent a possible d contribution may modify it. In fact, it has been shown that, for less localized states (as, e.g., the 3d states in transition metals) the resonant enhancement of the response is less pronounced than expected. [Pg.258]

Despite the fact that formalism of the standard chemical kinetics (Chapter 2) was widely and successfully used in interpreting actual experimental data [70], it is not well justified theoretically in fact, in its derivation the solution of a pair problem with non-screened potential U (r) = — e2/(er) is used. However, in the statistical physics of a system of charged particles the so-called Coulomb catastrophes [75] have been known for a long time and they have arisen just because of the neglect of the essentially many-particle charge screening effects. An attempt [76] to use the screened Coulomb interaction characterized by the phenomenological parameter - the Debye radius Rd [75] does not solve the problem since K(oo) has been still traditionally calculated in the same pair approximation. [Pg.372]

To demonstrate the charge screening importance in a many-particle system, it should be mentioned that the substitution of potentials il (r, t) entering equations (6.3.2), (6.3.3) by non-screened potentials Uu(r) = L/r leads to the Coulomb catastrophe manifesting itself by the unlimited increase of the reaction rate K(t) [24, 78],... [Pg.374]

Fig. 2 Glucose yield from non-screened bagasse pretreated with alkaline hydrogen peroxide, a Pretreatment time of 6 h. b Pretreatment time of 24 h... Fig. 2 Glucose yield from non-screened bagasse pretreated with alkaline hydrogen peroxide, a Pretreatment time of 6 h. b Pretreatment time of 24 h...
The reaction was found to be catalysed by the presence of chromium. In a separate investigation, the concentration dependence of the lattice parameters of this monocarbide, together with those of TiC, HfC, VC, NbC, and TaC, has been investigated. It has been shown that the significant factor affecting the parameters is whether the equilibrium M— C distance is associated with a lattice parameter greater or less than that produced by a non-screened M—M interaction. An electron diffraction study of one of these non-stoicheiometric carbides, VCi jj, which is cubic, and the hexagonal has also been completed. [Pg.236]

Figure 12.4 Dependence of a number of non-screened points at the surface of a filler particle N on the difference of fractal dimensions of the filler surface and polymer. Ad, for 1 PHE-Gr-I and 2 PHE-Gr-II. Figure 12.4 Dependence of a number of non-screened points at the surface of a filler particle N on the difference of fractal dimensions of the filler surface and polymer. Ad, for 1 PHE-Gr-I and 2 PHE-Gr-II.
Aq denotes the contribution of the (non-screened) orientation and induction interactions to the Hamaker constant... [Pg.318]

If a PSA model is available, then the effort for performing the system modeling is greatly reduced, since the seismic-induced failures of the non-screened components merely need to be added to the existing fault trees. A major benefit of reusing an existing PSA model is also the possibility to analyze mixed cutsets, i.e., combinations of seismic-induced and non-seismic-induced failures, such as random component failures or human (operator) errors. [Pg.3037]

The threshold value for screening out non significant AE sources is calculated on the basis of the mean (m) and of the standard deviation (a) TH = (m+Na), where N is an input floating variable. [Pg.68]

In plant maintenance, the availability of quantitative and non-invasive screening NDT methods will reduce the time needed for shutdowns and increase the intervals between them. Modem NDT methods will become just as important a tool for Risk Based Inspection approaches and maintenance planning as operational parameters and degradation mechanisms already are. [Pg.951]

Another application of laser-based profilometry is the inspection of rocket and missile components. The U.S. Air Force has funded work to develop a non-contact laser-based profilometer for the inside surface of solid rocket motors. Over time, these devices are subject to slumping and cracking, which could potentially render the rocket motor ineffective and hazardous. When fully implemented, this system will provide a meaningful screening method for evaluating the condition of aging rocket motors. [Pg.1066]

For non-Newtonian fluids in slow flow, friclion loss across a square-woven or fuU-twill-woven screen can be estimated by considering the screen as a set of parallel tubes, each of diameter equal to the average minimal opening between achacent wires, and length twice the diameter, without entrance effects (Carley and Smith, Polym. Eng. Set., 18, 408-415 [1978]). For screen stacks, the losses of individual screens should be summed. [Pg.646]

Carbon steel heat exchangers, cast iron water boxes, screens, pump components, service water system piping, standpipes, fire protection systems, galvanized steel, engine components, and virtually all non-stainless ferrous components are subject to significant corrosion in oxygenated water. [Pg.106]

While some video display screens such as liquid crystal, gas plasma or vacuum fluorescent displays do not present the same charged screen hazards as CRTs, this does not imply that they are safe for use in hazardous locations. This requires special design and certification for use with a given flammable atmosphere. Non-certified equipment used in locations classified as hazardous under Article 500 of NFPA 70 National Electrical Code require a purged or pressurized enclosure to control ignition hazards as described in NFPA 496 Standard for Purged and Pressurized Enclosures for Electrical Equipment. The screen in this case is located behind a window in the enclosure. [Pg.165]

The fourth source type option in SCREEN is for volume sources, which is selected by entering V or V for source type. The volume source algorithm is based on a virtual point source approach, and may be used for non-buoy ant sources whose emissions occupy some initial volume. The inputs requested for volume sources are as follows ... [Pg.312]

The use of the methods of Briggs to estimate plume rise are relied on in the SCREEN model. Stack tip downwash is estimated following Briggs (1973, p.4) for all sources except those employing the Schulman-Scire downwash algorithm. Buoyancy flux for non-flare point sources is calculated from ... [Pg.316]

Cavity Recirculation Region - The cavity calculations are based largely on results published by Hosker (1984). If non-zero building dimensions are input to SCREEN for either point or flare releases, then cavity calculations will be made as follows. The cavity height, h,.(m), is estimated based on the following equation from Hosker (1984) ... [Pg.318]

FUter medium The permeable portion of a filtration system that provides the liquid-solid separation, such as screens, papers, non-wovens, granular beds and other porous media. [Pg.614]

In addition to the development of the powerful chiral additive, this study also demonstrated that the often tedious deconvolution process can be accelerated using HPLC separation. As a result, only 15 libraries had to be synthesized instead of 64 libraries that would be required for the full-scale deconvolution. A somewhat similar approach also involving HPLC fractionations has recently been demonstrated by Griffey for the deconvolution of libraries screened for biological activity [76]. Although demonstrated only for CE, the cyclic hexapeptides might also be useful selectors for the preparation of chiral stationary phases for HPLC. However, this would require the development of non-trivial additional chemistry to appropriately link the peptide to a porous solid support. [Pg.66]


See other pages where Non screening is mentioned: [Pg.135]    [Pg.374]    [Pg.160]    [Pg.337]    [Pg.153]    [Pg.153]    [Pg.305]    [Pg.135]    [Pg.374]    [Pg.160]    [Pg.337]    [Pg.153]    [Pg.153]    [Pg.305]    [Pg.443]    [Pg.595]    [Pg.2208]    [Pg.2209]    [Pg.2219]    [Pg.657]    [Pg.472]    [Pg.281]    [Pg.489]    [Pg.117]    [Pg.141]    [Pg.304]    [Pg.313]    [Pg.118]    [Pg.297]    [Pg.341]    [Pg.800]    [Pg.80]    [Pg.205]    [Pg.215]    [Pg.83]    [Pg.373]   
See also in sourсe #XX -- [ Pg.251 , Pg.371 ]

See also in sourсe #XX -- [ Pg.251 , Pg.371 ]




SEARCH



Effect of non-equilibrium charge screening (Coulomb interaction)

Non-adiabatic screening tests

© 2024 chempedia.info