Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Micro manipulator

The preparations of all the derivatives, and all the hydrolyses of esters, anilides, etc., described in Part III, provide excellent practice in semi-micro manipulation. [Pg.71]

The sample preparation in LC analysis is as important as the chromatographic separation itself. The procedure will often require considerable skill copied with a basic understanding of chromatographic methodology. The analyst will need to have some familiarity with micro techniques including general micro-manipulation, microfiltration, centrifugation and derivatization. [Pg.195]

Future medical training, diagnosis and - even surgical - treatment will increasingly be performed remotely. Thus, the combination of sophisticated sensory devices with advanced micro-manipulation equipment will, together with 3D interactive feedback models, provide new tools and approaches for the medical profession. [Pg.148]

Fig. 1.5 SEM micrographs of (A) donut-shaped poly(aspartate) and MgCl2 by alternate spin CaC03 crystals grown on polyacrylic acid grafted coating and crystallization. (A) and (B) adapted chitosan, (B) CaC03 hollow helix, fractured by from [84] and [85]with permission from Elsevier, micro-manipulation, formed on poly(a-L-aspar- and (C) from [88] (reproduced by permission of tate),and (C) double layered aragonitethin films The Royal Society of Chemistry), grown on a chitosan matrix in the presence of... Fig. 1.5 SEM micrographs of (A) donut-shaped poly(aspartate) and MgCl2 by alternate spin CaC03 crystals grown on polyacrylic acid grafted coating and crystallization. (A) and (B) adapted chitosan, (B) CaC03 hollow helix, fractured by from [84] and [85]with permission from Elsevier, micro-manipulation, formed on poly(a-L-aspar- and (C) from [88] (reproduced by permission of tate),and (C) double layered aragonitethin films The Royal Society of Chemistry), grown on a chitosan matrix in the presence of...
The two metal surfaces covered by SAMs are brought into contact by the use of a micro-manipulator in the presence of a liquid medium, such as hexadecane the presence of hexadecane transforms the defects of the SAMs into insulating sites. The use of a semitransparent solid surface (Au or Ag) allows (1) evaluation of the contact area by collecting the image of the contact area by a mirror and (2) electrical measurements under irradiation of the SAMs through the Au surface. The disadvantage of Hg-based junctions is related to the environmental unfriendly characteristics of Hg, which prevent any application. For this main reason, these junctions are valuable only as versatile test-beds for organic electronics. [Pg.99]

A clever way to minimize the unwanted background from the cover plate or the environment is combining laser tweezers and confocal Raman spectroscopy (LTRS) [73, 74], While the single cells are levitated well off the surface and held in the focus of the laser beam the Raman spectral patterns of these cells are recorded with high sensitivity. Another appealing fact is the usage of one laser for both Raman excitation and optical trapping to keep the instrumental efforts as low as possible. Additionally the trapped cells can also be micro-manipulated and moved from one place to another, e.g., from the native matrix to a clean collection chamber. [Pg.453]

Micro-manipulator with three axis, 1 xm resolution and digital display readout (David Kopf, Model 1940). [Pg.285]

Dial test indicator (David Kopf, Model 1910). This tool is used to level the micro-manipulator arm with respect to the base unit during setup of the stereotaxic alignment system, according to the manufacturer s instructions. It is not required during actual surgery. [Pg.285]

Recent advances in micro-manipulation and hybridization, fluorescence labeling, and large-scale sequencing projects have led to new methods of expression profiling and genome analysis, loosely termed microarray analysis. This is an oblique description for a number of methods that utilize hybridization of labeled complex RNA probes to immobilized nucleotides arrayed at high density on a solid substrate to provide quantifiable data on relative expression levels. [Pg.100]

Abstract. Programmable manipulation of particles or cells plays an important role in many biological and medical applications. Here a new programmable micro manipulator, named lab-on-a-display, in which particles are manipulated by optically induced electrokinetic forces generated from an optoelectronic tweezers on a liquid crystal display, is introduced. This optoelectrofluidic platform has been utilized to manipulate various kinds of cells such as blood cells, oocytes, and motile bacteria for several biotechnological applications. [Pg.595]

The apparatus has been reported previously ( ). The micro-manipulator had coarse control in the X and Y axes and a precise vernier for the Z axis. A reference plane was established by lowering the microprobe until electrical contact was established at points several millimeters away from the colony in all directions. The colony was traversed by the microprobe at the center line, at several locations progressing toward the edge, and adjacent agar was also probed. Small, medium, and large colonies were selected. [Pg.396]

For micro-pyrolysis-td-GC-MS, the sorbent tube is modified to end in a short section of stainless steel hypodermic tubing the open end of which can be placed immediately adjacent to the heated thermal probe using a micro-manipulator. As the tip is heated, a pump is used to draw gas through the tube. After sampling, the tube is placed in a suitable carrier that fits into a standard thermal desorption unit interfaced to a GC-MS system. Blank desorption runs of the... [Pg.78]

T. Kikuchi, Y. Akiyama, M. Ueda, M. Sakairi, and H. Takahashi, Fabrication of a three-dimensional micro-manipulator by laser irradiation and electrochemical techniques and the effect of electrolytes on its performance, Electrochim. Acta, 52 (13), 4480 1486, (2007). [Pg.627]

Haake A, Dual J (2002) Micro-manipulation of small particles by node position control of an ultrasonic standing wave. Ultrasonics 40 317-322... [Pg.1544]

Ataka, M., Fujita, H. and Mita, M. (2010) 2D Planar Micro Manipulator by Stack-Integrated Micro Actuator/Sensor Array , First Workshop on Hardware and Software Implementation and Control of Distributed MEMS (DMEMS), Besan, TBD, France. [Pg.93]

Fig. 3 Complex form of inorganic minerals formed by crystallization under control of a simple polyelectrolyte, a Helical CaC03 structures produced by the PILP process. Occasionally, the helices are partially hollow. The hollow helix fractured by micro-manipulation. The scale bar represents 10 xm. (Reproduced from [91], 1998, Elsevier Sciences), b Scanning electron microscopy (SEM) image of octacalcium phosphate (OCP)-polyelectrolyte architectures synthesized in the presence of polyaspartate, and isolated after different periods of aging, in solution for 3 h. The scale bar represents 100 xm. (Reproduced from [94], 2002, Wiley). c,d Complex forms of BaS04 bundles and superstructures produced in the presence of 0.11 mM sodium polyacrylate (M = 5100), at room temperatme, [BaS04] = 2 mM, pH = 5.3, 4 days, c The detailed superstructures with repetitive patterns. (Reproduced from [96], 2003, American Chemical Society), d A zoomed SEM image of the well-aligned bundles. (Reproduced from [37], 2005, MRS)... Fig. 3 Complex form of inorganic minerals formed by crystallization under control of a simple polyelectrolyte, a Helical CaC03 structures produced by the PILP process. Occasionally, the helices are partially hollow. The hollow helix fractured by micro-manipulation. The scale bar represents 10 xm. (Reproduced from [91], 1998, Elsevier Sciences), b Scanning electron microscopy (SEM) image of octacalcium phosphate (OCP)-polyelectrolyte architectures synthesized in the presence of polyaspartate, and isolated after different periods of aging, in solution for 3 h. The scale bar represents 100 xm. (Reproduced from [94], 2002, Wiley). c,d Complex forms of BaS04 bundles and superstructures produced in the presence of 0.11 mM sodium polyacrylate (M = 5100), at room temperatme, [BaS04] = 2 mM, pH = 5.3, 4 days, c The detailed superstructures with repetitive patterns. (Reproduced from [96], 2003, American Chemical Society), d A zoomed SEM image of the well-aligned bundles. (Reproduced from [37], 2005, MRS)...
Other Robotic Microassembly Platform based micro-manipulation, where parts are placed and assembled in a known environment using methods other than pick-... [Pg.1142]

Ferrari E, Emiliani V, Cojoc D, Garbin V, Zahid M, Durieux C, Coppey-Moisan M, Di Fabrizio E (2005) Biological samples micro-manipulation by means of optical tweezers. Microelectron Eng 78-79 575-581... [Pg.1859]

Sections of the dry reagent films were removed around the perimeter of the IDA electrodes with the use of a micro-manipulator tip and a Cambridge stereo zoom microscope (see below). A Dektak IIA step profiler was used to determine the approximate film thickness of the IDA electrodes. Electrodes were tested for shorts between the electrode fingers using a Fluke 87 multimeter prior to electrochemical testing. [Pg.53]

Figure 24.5 Diagiam of the method of microaspiration of a vesicle. The experiments were carried out in the open chamber described in the caption for Figure 24.3. With a micro-manipulator a microcapillary (tip inner diameter 5l pm) was positioned near the targeted DMPC-CL vesicle containing polymerized actin. The aspiration pressure was adjusted by changing the height of the water column in the reservoir. The figure is not drawn to scale. Figure 24.5 Diagiam of the method of microaspiration of a vesicle. The experiments were carried out in the open chamber described in the caption for Figure 24.3. With a micro-manipulator a microcapillary (tip inner diameter 5l pm) was positioned near the targeted DMPC-CL vesicle containing polymerized actin. The aspiration pressure was adjusted by changing the height of the water column in the reservoir. The figure is not drawn to scale.
A microelectrode was made of a Teflon-coated platinum wire having a diameter of 50 pm. The microelectrode was installed with a micro-manipulator. An Ag/AgCl reference electrode (1 mm (dia) x 10 mm) and... [Pg.624]

Perovskite type layered structures and especially layered oxides are intensively studied because they exhibit a wealth of "modem" physical phenomena, such as high-Tc superconductivity, colossal magnetoresistance, ferroelectricity and quantum critical behavior. Due to this layered oxides create the basis for many technological applications including information storage and transmission, micro-electronics and micro-manipulation. [Pg.346]


See other pages where Micro manipulator is mentioned: [Pg.610]    [Pg.109]    [Pg.24]    [Pg.538]    [Pg.222]    [Pg.85]    [Pg.151]    [Pg.339]    [Pg.82]    [Pg.215]    [Pg.77]    [Pg.93]    [Pg.404]    [Pg.93]    [Pg.93]    [Pg.79]    [Pg.81]    [Pg.87]    [Pg.458]    [Pg.170]    [Pg.472]    [Pg.55]    [Pg.182]    [Pg.700]   
See also in sourсe #XX -- [ Pg.29 , Pg.33 ]




SEARCH



Manipulation on a Semi-micro Scale

Manipulation semi-micro

Micro-manipulation

Micro-scale manipulations

© 2024 chempedia.info