Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sensory device

Primary sensory device not installed (i.e., orifice plate, temperature bulb). [Pg.328]

Dry bulb The air temperature recorded by a dry bulb thermometer, a sensory device excluding any effects of moisture or radiation. [Pg.1480]

Future medical training, diagnosis and - even surgical - treatment will increasingly be performed remotely. Thus, the combination of sophisticated sensory devices with advanced micro-manipulation equipment will, together with 3D interactive feedback models, provide new tools and approaches for the medical profession. [Pg.148]

The aim of this overview is first to present the general principles of electrocatalysis by metal complexes, followed by a series of selected examples published over the last 20 years illustrating the major electrochemical reactions catalyzed by metal complexes and their potential applications in synthetic and biomimetic processes, and also in the development of sensory devices. The area of metal complex catalysts in electrochemical reactions was reviewed in 1990.1... [Pg.472]

There is an increasing interest in the development of electrochemical sensors and microsensors for detecting and monitoring NO or N02, due to their importance in clinical and environmental analysis. It has been suggested that transition metal electrocatalysts active for NO or N02 coordination and reduction could be exploited for the development of metal-complex film electrodes for N02 and NO sensing. However, most of the sensory devices reported so... [Pg.492]

This concept is in essence a chromatographic effect similar to that observed in gas chromatography (GC), with the conjugated polymer film acting as the stationary phase. It is possible that like in GC and other candidate technologies for explosive detection, these responses could be empirically standardized for expected analytes of interest and sensory devices caHbrated to deconvolute temporal quenching signals to determine which analytes are present. This would further enhance the selectivity of what is already a very selective sensor for TNT and related compounds. [Pg.218]

The possibility of measurement of Mg2+ concentration in a matrix complicated by alkali and alkaline earth metal ions has been explored by titration of 68 (5 x 10-5 M) in 1 1 MeOH/H20 solution (pH 7.2) containing Na+ (5 x 10 3 M), K+ (1 X 10-3 M), Ba2+ (1 x 10 3 M), Sr2 (1 x 1(T3 M), and Ca2+ (1 x 10-4 M). The titration was monitored via fluorescence.125 The fluorescence intensity reached a maximum at 1 equiv of Mg2+, indicating that fluorescent intensity could be directly correlated to Mg2+ concentration. The lack of interference from the other metal ions present can be a result of their lower binding constants with 68 and lower quantum yields of the charged complexes of 68 with Na+, K+, Ca2+, Sr2+, and Ba2+ at this pH. Thus, ligand 68 possesses characteristics of an efficient fluorescent chemosensor for Mg2+ and may find use in determining Mg2+ in biological samples and, if immobilized on a solid support, may be incorporated into sensory devices for measurement of Mg2+ concentrations in aqueous solutions. [Pg.120]

The far left part of the spectrum deals with the control hardware and infrastructure required to operate a plant. We need to assemble the proper types of control valves and process measurements (for temperature, flow, pressure, composition, etc.). These are the sensory devices of the plant and are essential for any control system to function. Any control strategy, no matter how clever, will have severe difficulties without the right measurements and valves in the process. An Instrument Society of America (ISA) publication catalog (67 Alexander Drive, P.O. Box 12277, Research Triangle Park, NC 27709) contains many references that deal with control hardware. [Pg.13]

Figure 3. Amperometric sensory device scheme of electrochemical ion transport with a redox-active crown ether. W, W minigrid platinum working electrodes. C , C platinum plate counter electrode. R, R SCE reference. Figure 3. Amperometric sensory device scheme of electrochemical ion transport with a redox-active crown ether. W, W minigrid platinum working electrodes. C , C platinum plate counter electrode. R, R SCE reference.
Redox reagents are useful for stoichiometric electron-transfer reactions, catalytic initiation of electron-transfer-chain (ETC) catalyzed reactions, as redox mediators (by outer-sphere electron transfer) or redox catalysts (by inner-sphere electron transfer) of redox reactions, as part of sensory devices when then are attached to... [Pg.1452]

Skeletal muscles are controlled by large nerves in the spinal cord. The nerve cell or neuron is part of the spinal cord, but its projections, the axon and the many dendrites course outward to connect to muscle cells. The nerve axon is a sensory device that senses the muscle cells current condition. The dendrites are motor fibers that deliver the instructions to change its state to the muscle fiber. The area at which the muscle and nerve connect is called the neuromuscular junction. It is here that the end releases a chemical called a neurotransmit-ter that crosses the microscopic space between the nerve and muscle and causes the desired response. Five such neurotransmitters have been described acetylcholine, serotonin, norepinephrine, glycine, and gamma-ammi-nobutyric acid or GABA. Of these, the functions of three are known. Acetylcholine excites muscle activity and glycine and GABA inhibit it. [Pg.454]

Some chemical substances have been used in the past as switches to control ion transport. Several new molecular sensory devices, which are responsive crown ethers used for the dynamic control of cation and anion binding induced by changes in pH, redox potential, temperature, light, and magnetic and electrical field, have been developed. These new ligands possess chromophores or fluorophores linked to the macrocycle, and display drastic variations in their photochemical and/or luminescent properties upon cation complexation. [Pg.235]

Techniques of generating false radio or radar emissions that match those of other sources, even the enemy s own, to act as decoys for potential targets are well enough known. More recently the practice of emitting infra-red transmissions corresponding to those of the ambient environment has permitted military vehicles to hide from the sensory devices of enemy tracking equipment. [Pg.76]

In a step towards the fabrication of prototype sensory devices organisation of redox-active anion receptors on to electrode surfaces is being exploited. Importantly, self-assembled monolayers or thin polymer films of metal-based receptors can generate an amplified response to anion binding akin to the dendritic effect and could potentially become the basis of robust anionsensing devices. [Pg.63]

As with other types of sensory devices, optical and infrared detectors are capable of being classified as to their operating mode. Their performance can be described in terms of unique figures of merit which enable the system designer to predict, then evaluate, the performance of the system in which they are employed. And, like all sensors, their performance cannot exceed that of an ideal device o f their class fundamental limits exist which constrain their performance. [Pg.5]

Loxedes barium sulfate crystals are employed to control balance or orientation when the dense crystal deflects, displaces, or distorts a sensory device under the influence of gravity [11]. [Pg.257]


See other pages where Sensory device is mentioned: [Pg.255]    [Pg.57]    [Pg.2]    [Pg.208]    [Pg.49]    [Pg.194]    [Pg.195]    [Pg.2]    [Pg.108]    [Pg.111]    [Pg.1]    [Pg.185]    [Pg.213]    [Pg.37]    [Pg.194]    [Pg.195]    [Pg.81]    [Pg.140]    [Pg.627]    [Pg.885]    [Pg.308]    [Pg.134]    [Pg.113]    [Pg.308]    [Pg.162]    [Pg.7179]    [Pg.748]    [Pg.342]    [Pg.229]    [Pg.370]    [Pg.680]   
See also in sourсe #XX -- [ Pg.11 , Pg.789 ]




SEARCH



© 2024 chempedia.info