Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Coatings Teflon

Powder Coating. Teflon PEA is also available in a finely divided powder form. It can be used to produce thin layers on various surfaces by heating these surfaces above the melting point of PEA and then bringing the powder in contact with them. This allows a thin layer of the powder to melt on the surface of the substrate. [Pg.377]

One significant development in recent years has been the widespread treatment of clothing fabrics to give a measure of water and stain resistance. Mention may also be made of the expression Teflon-coated (Teflon is the DuPont trade name for PTFE) to describe a person, usually a politician, to whom no dirt (i.e. scandal) sticks, a reflection of the non-stick characteristics of the polymer ... [Pg.373]

Fiberglass Coating Teflon Emulsion, Fiberglass, Synthetics, Styrene... [Pg.472]

Goudonnet J.P., Begun G.M., Arakawa E.T., Surface-enhanced Raman-scattering on silver-coated Teflon sphere substrates, Chem. Phys. Lett. 1982 92 197-201. [Pg.256]

The defoaming of blood is usually accomplished with the aid of silicone-coated mesh. Dimethylpolysiloxane-based antifoams can be used to coat Teflon or steel or polypropylene mesh. A settling chamber is used separately or as part of the defoaming chamber to allow all residual bubbles to escape. [Pg.213]

Atlas FA 10OH Atlas FA 10OS Aflas FA 150E Aflas FA 1 SOL Aflas FA 1 SOP fluoropolymer, extruded film Dyneon THV 220G fluoropolymer, glass fabric coatings Teflon PTFE 30B... [Pg.1535]

Ken-React QB 012 Ken-Read QB 321 Ken-React QB 521 perIbniBnce enhatEcr, coatings Teflon MP1200... [Pg.1563]

There are a number of options for using a fluorescence cell in the conventional 90° orientation. One 90° cell incorporated a chair shaped gold coated Teflon electrode milled to fit into a conventional fluorescence cuvette. The large Teflon insert provided was also milled to support the reference and auxiliary electrodes at the bottom of the cell. The size of the insert significantly reduced the volume of the cell permitting use of 90° excitation and detection (44). Another 90° oriented cell is shown in Figure 14.15 (45) where a quartz... [Pg.613]

Passive diffnsion of accelerant vapors onto an adsorbent placed inside the container of fire debris has gained wide acceptance in the United States because it is nonlaborious and takes little time to perform. Dietz (182) has reported a procedure that uses activated carbon-coated Teflon strips, similar to devices used in enviromnental monitoring badges, to recover as little as 0.2 tiL of an equal mixture of gasoline, kerosene, and diesel fuel. Neuman (183) reported on the optimized method as well as the effects of time, temperature, strip size and sample concentration. The most recent recommended procedure heats the samples at approximately 60-80°C for 8-24 hs (184). The optimum adsorption time for maximum sensitivity will depend on the adsorption package, the sample itself, and the temperatures. The accelerants are desorbed with carbon disulfide, which can be concentrated to improve sensitivity and shows little response, but may cause a pressure disturbance to the FID. Another advantage to this technique is the fact that multiple analyses may be performed from one sample. The carbon strip can be easily cut into smaller pieces, placed into vials, and frozen for later analysis. [Pg.939]

Polytetrafluoroethylene (PTFE a.k.a. Teflon) cookware coating, teflon tape... [Pg.375]

The answer is 3 [IIC Tible 15-1]. The halocarbon compounds (e.g., chloroform, halothane, freon) and the fumes from overheated synthetic fluorine-containing resin-coated (Teflon) cookware are indirectly car-diotoxic because they sensitize the heart to sympathomimetic amines such as epinephrine. Following exposure to these substances, even the release of endogenous epinephrine associated with stress can pose a hazard. Yew plants contain a cardioactive alkaloid that inhibits depolarization and produces bradycardia and diastolic heart block. Furazolidone interferes with intermediary metabolism, resulting in a lack of energy arid a dilated, weak heart "round heart." Digitalis aflecTs potassium content in the cell. Monensin is an ionophore that alters the sodium-to-calcium ratio arid leads Id cardiac necrosis. [Pg.169]

Before TERS was considered, scanning near-held optical microscopy (SNOM) in combination with SERS was used to perform high-resolution structural DNA analysis [73]. In those experiments, brilliant cresyl blue (BCB)-labeled DNA was adsorbed on silver-coated Teflon spheres in order to examine the correlation between topography and near-held Raman spectra. [Pg.488]


See other pages where Coatings Teflon is mentioned: [Pg.753]    [Pg.86]    [Pg.232]    [Pg.234]    [Pg.194]    [Pg.3]    [Pg.71]    [Pg.491]    [Pg.291]    [Pg.121]    [Pg.187]    [Pg.571]    [Pg.336]    [Pg.778]    [Pg.1535]    [Pg.1593]    [Pg.443]    [Pg.449]    [Pg.232]    [Pg.234]    [Pg.650]   
See also in sourсe #XX -- [ Pg.7 , Pg.195 ]




SEARCH



Teflon