Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Measurement techniques specificity

Hundreds of chemical species are present in urban atmospheres. The gaseous air pollutants most commonly monitored are CO, O3, NO2, SO2, and nonmethane volatile organic compounds (NMVOCs), Measurement of specific hydrocarbon compounds is becoming routine in the United States for two reasons (1) their potential role as air toxics and (2) the need for detailed hydrocarbon data for control of urban ozone concentrations. Hydrochloric acid (HCl), ammonia (NH3), and hydrogen fluoride (HF) are occasionally measured. Calibration standards and procedures are available for all of these analytic techniques, ensuring the quality of the analytical results... [Pg.196]

The continuous methods combine sample collection and the measurement technique in one automated process. The measurement methods used for continuous analyzers include conductometric, colorimetric, coulometric, and amperometric techniques for the determination of SO2 collected in a liquid medium (7). Other continuous methods utilize physicochemical techniques for detection of SO2 in a gas stream. These include flame photometric detection (described earlier) and fluorescence spectroscopy (8). Instruments based on all of these principles are available which meet standard performance specifications. [Pg.201]

A difficulty that should not be overlooked is that airborne particulates are rarely homogeneous. They vary greatly in size and shape, and their chemical composition is determined by factors specific to the source and location of the emissions. The combined effects and interactions of various substances mixed with particulates have not yet been established (except for sulfur dioxide), but they are believed to be significant, especially where long-term exposure occurs. Measurement techniques and their reliability may vary across regions and countries, and so may other factors, such as diet, lifestyle, and physical fitness, that influence the human health effects of exposure to particulates. [Pg.19]

Discussion. Because of the specific nature of atomic absorption spectroscopy (AAS) as a measuring technique, non-selective reagents such as ammonium pyrollidine dithiocarbamate (APDC) may be used for the liquid-liquid extraction of metal ions. Complexes formed with APDC are soluble in a number of ketones such as methyl isobutyl ketone which is a recommended solvent for use in atomic absorption and allows a concentration factor of ten times. The experiment described illustrates the use of APDC as a general extracting reagent for heavy metal ions. [Pg.184]

Reliable micro-scale measurement and control of the temperature are required in developing thermal micro-devices. Available measurement techniques can be largely classified into contact and non-contact groups. While the resistance thermometer, thermocouples, thermodiodes, and thermotransistors measure temperature at specific points in contact with them, infrared thermography, thermochromic liquid crystals (TLC), and temperature-sensitive fluorescent dyes cover the whole temperature field (Yoo 2006). [Pg.27]

As usually viewed by the reference material producers, a fundamental philosophy of certification rests on the concept of independent methodology, which is the application of theoretically and experimentally different measurement techniques and procedures to generate concordant results leading to one reliable assigned value for the property. Such assigned values are thus method-independent. Extractable concentrations are generated by specific procedures and are thus method-dependent, an idea that has to be rationalized with the fundamental method-independent concept in reference material certification work. [Pg.286]

Measurement of specific activity. The half-life of a nuclide can be readily calculated if both the number of atoms and their rate of decay can be measured, i.e., if the activity A and the number of atoms of P can be measured, then X is known from A = XP. As instrumentation for both atom counting and decay counting has improved in recent decades, this approach has become the dominant method of assessing half-lives. Potential problems with this technique include the accurate and precise calibration of decay-counter efficiency and ensuring sufficient purity of the nuclide of interest. This technique provides the presently used half-lives for many nuclides, including those for the parents of the three decay chains, U, U (Jaffey et al. 1971), and Th. [Pg.15]

Calorimetry. Radioactive decay produces heat and the rate of heat production can be used to calculate half-life. If the heat production from a known quantity of a pure parent, P, is measured by calorimetry, and the energy released by each decay is also known, the half-life can be calculated in a manner similar to that of the specific activity approach. Calorimetry has been widely used to assess half-lives and works particularly well for pure a-emitters (Attree et al. 1962). As with the specific activity approach, calibration of the measurement technique and purity of the nuclide are the two biggest problems to overcome. Calorimetry provides the best estimates of the half lives of several U-series nuclides including Pa, Ra, Ac, and °Po (Holden 1990). [Pg.15]

The Doppler-selected TOF technique is one of the laser-based techniques for measuring state-specific DCSs.30 It combines two popular methods, the optical Doppler-shift and the ion TOF, in an orthogonal manner such that in conjunction with the slit restriction to the third dimension, the desired center-of-mass three-dimensional velocity distribution of the reaction product is directly mapped out. Using a commercial pulsed dye laser, a resolution of T% has been achieved. As demonstrated in this review, such a resolution is often sufficient to reveal state-resolved DCSs. [Pg.37]

Levels of RNA (usually specific mRNAs) in a cell can be measured by well-established techniques such as northern blot analysis or by PCR analysis. However, the recent advent of DNA microarray technology has converted the identification and measurement of specific mRNAs (or... [Pg.61]

As mentioned earlier, the response of each protein will vary. This is especially apparent with colorimetric assays or derivatization methods requiring a chemical reaction. These protein-to-protein reactivity differences mean that a protein assay suitable for one protein may not be suitable for another. Even for a given protein and a specific protein determination method, results may still vary based on limitations of the assay. Methods requiring extensive sample preparation including protein concentration, buffer exchange, and time-sensitive reactions are liable to be less reproducible than direct measurement techniques, which have fewer variable parameters. The application will determine the suitability of the method. [Pg.26]

The separator resistance is usually characterized by cutting small pieces of separators from the finished material and then placing them between two blocking electrodes. The separators are completely saturated with the electrolyte. The resistance (Q) of the separator is measured at a certain frequency by ac impedance techniques. The frequency is chosen so that the separator impedance is equal to the separator resistance. To reduce the measurement error, it is best to do multiple measurements by adding extra layers. The average resistance of single layer is determined from multiple measurements. The specific resistivity, ps cm), of the separator saturated... [Pg.191]


See other pages where Measurement techniques specificity is mentioned: [Pg.145]    [Pg.285]    [Pg.293]    [Pg.161]    [Pg.145]    [Pg.285]    [Pg.293]    [Pg.161]    [Pg.65]    [Pg.209]    [Pg.350]    [Pg.126]    [Pg.404]    [Pg.101]    [Pg.368]    [Pg.189]    [Pg.245]    [Pg.85]    [Pg.689]    [Pg.535]    [Pg.265]    [Pg.160]    [Pg.782]    [Pg.323]    [Pg.208]    [Pg.287]    [Pg.472]    [Pg.159]    [Pg.64]    [Pg.252]    [Pg.82]    [Pg.339]    [Pg.398]    [Pg.97]    [Pg.169]    [Pg.76]    [Pg.418]    [Pg.63]    [Pg.136]    [Pg.190]    [Pg.172]    [Pg.522]   
See also in sourсe #XX -- [ Pg.215 ]




SEARCH



Specific measurements

Specificity, measurement

© 2024 chempedia.info