Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Matched background

R.L. Williams and G. Vigh, Maximization of separation efficiency in capillary-electrophoretic chiral separations by means of mobility matching background electrolytes, J. Chromatogr. A., 730, 273,1996. [Pg.224]

This section reviews the reactor landfill and the processes present within the landfill system. The primary objective of a landfill system is to ensure that waste deposited within the system reaches a final storage quality as rapidly as possible which matches background levels of the earth s crust. Past landfill strategy has simply been to deposit waste in derelict voids or land depressions in the most cost-effective manner with no consideration of the long-term impact on the environment. [Pg.187]

The matrix for the standards and the blank should match that of the samples thus, an appropriate matrix is 0.75 M HNO3. Any interferences from other components of the sample matrix are minimized by background correction. [Pg.421]

Thermal ionization has three distinct advantages the ability to produce mass spectra free from background interference, the ability to regulate the flow of ions by altering the filament temperature, and the possibility of changing the filament material to obtain a work function matching ionization energies. This flexibility makes thermal ionization a useful technique for the precise measurement of isotope ratios in a variety of substrates. [Pg.389]

The infra-red measurements were of two types, normal-film measurements with the sample sandwiched between KBr plates, and tilted-film experiments with the sample sandwiched between 45° prisms of KBr, in each case with layers of Nujol to provide optical matching. Whereas the 1616 cm 1 Raman line occurs in a region well clear of other lines so that it was satisfactory to measure peak intensities, the infra-red spectrum of PET shows many overlapping bands. Accurate assessment of absorption intensities therefore requires the computer separation of the spectrum into a set of overlapping peaks (shown to be Lorentzian in profile) and a linear background. The procedures adopted and the band assignments are discussed in detail by Hutchinson et al. 6). [Pg.103]

In terms of matching mentors with mentees, BAT takes the view that there should be balance between the similar and dissimilar personalities or backgrounds of the two parties. Compatibility depends on the individuals personality type, learning, and communication style. [Pg.71]

The axiomatic teaching of Newtonian mechanics (NM)(I, 2), with or without calculus, is very effective. The abstract concepts are quickly connected by students to the practical experience and intuitive insight they have developed throughout their lives. This access to their own direct experience allows each student to make the necessary adjustments and corrections to the abstract concepts if the way they are presented by one particular teacher following one particular textbook does not optimally match the particular student s style and background. As a result, the majority of students of NM gain an effective level of understanding and skill within the time of the course. [Pg.22]

Hirose et al. [26] proposed a homodyne scheme to achieve the background-free detection of the fourth-order field. With pump irradiation in a transient grating configuration, the fourth-order field propagates in a direction different from that of the second-order field because of different phase match conditions. The fourth-order field is homodyned to make ffourth(td. 2 D) and spatially filtered from the second-order response hecond td, 2 D). [Pg.106]

The target for optimization in FTA with CL detection is to adjust all experimental factors in such a way so that the detector views as much radiation as possible while the chemiluminescent solution flows through the cell. Hence the kinetics of the flow and detector system should be monitored to match the kinetics of the reaction and generate maximum intensity inside the cell. The effect of experimental variables on the CL signal cannot be exactly predicted in advance and there is not enough theoretical background to support any suggestion. [Pg.331]

In conclusion, SERMs exhibit changes in inflammatory markers that do not match those found with oral HT. Some variability exists within HT itself, depending on the compound (estrogens or tibolone) and on the administration route (oral vs. transdermal). There is sufficient background to hold the value... [Pg.232]

Interferences in atomic absorption measurements can arise from spectral, chemical and physical sources. Spectral interference resulting from the overlap of absorption lines is rare because of the simplicity of the absorption spectrum and the sharpness of the lines. However, broad band absorption by molecular species can lead to significant background interference. Correction for this may be made by matrix matching of samples and standards, or by use of a standard addition method (p. 30 et seq.). [Pg.331]


See other pages where Matched background is mentioned: [Pg.121]    [Pg.86]    [Pg.126]    [Pg.151]    [Pg.159]    [Pg.139]    [Pg.121]    [Pg.86]    [Pg.126]    [Pg.151]    [Pg.159]    [Pg.139]    [Pg.115]    [Pg.741]    [Pg.1208]    [Pg.1976]    [Pg.1985]    [Pg.329]    [Pg.58]    [Pg.73]    [Pg.183]    [Pg.235]    [Pg.165]    [Pg.1148]    [Pg.54]    [Pg.78]    [Pg.626]    [Pg.51]    [Pg.446]    [Pg.156]    [Pg.276]    [Pg.78]    [Pg.80]    [Pg.80]    [Pg.81]    [Pg.127]    [Pg.140]    [Pg.495]    [Pg.305]    [Pg.240]    [Pg.167]    [Pg.134]    [Pg.239]    [Pg.191]   
See also in sourсe #XX -- [ Pg.126 ]




SEARCH



© 2024 chempedia.info