Sinha, A.E., Hope, J.L., Prazen, B.J., Fraga, C.G., Nilsson, E.J., Synovec, R.E. (2004a). Multivariate selectivity as a metric for evaluating comprehensive two-dimensional gas chromatography-time-of-fhght mass spectrometry subjected to chemometric peak deconvolution. J. Chromatogr. A 1056, 145-154. [Pg.34]

The following journals are either devoted entirely to articles on mass spectrometry or contain significant numbers of papers on the subject. They are obtainable through direct subscription or through library systems. [Pg.453]

Very little in the way of advances has occurred since 1971 in the applications of ultraviolet or infrared spectroscopy to the analysis of fluonnated organic compounds Therefore, only gas-liquid chromatography, liquid chromatography, mass spectrometry, and electron scattering for chemical analysis (ESCA) are discussed The application of nuclear magnetic resonance (NMR) spectroscopy to the analysis of fluonnated organic compounds is the subject of another section of this chapter... [Pg.1029]

Mass spectrometry is the subject of Major Technique 6, following Chapter 18. [Pg.476]

The combination of chromatography and mass spectrometry (MS) is a subject that has attracted much interest over the last forty years or so. The combination of gas chromatography (GC) with mass spectrometry (GC-MS) was first reported in 1958 and made available commercially in 1967. Since then, it has become increasingly utilized and is probably the most widely used hyphenated or tandem technique, as such combinations are often known. The acceptance of GC-MS as a routine technique has in no small part been due to the fact that interfaces have been available for both packed and capillary columns which allow the vast majority of compounds amenable to separation by gas chromatography to be transferred efficiently to the mass spectrometer. Compounds amenable to analysis by GC need to be both volatile, at the temperatures used to achieve separation, and thermally stable, i.e. the same requirements needed to produce mass spectra from an analyte using either electron (El) or chemical ionization (Cl) (see Chapter 3). In simple terms, therefore, virtually all compounds that pass through a GC column can be ionized and the full analytical capabilities of the mass spectrometer utilized. [Pg.19]

The mass spectrum produced should provide unambiguous molecular weight information from the wide range of compounds amenable to analysis by HPLC, including biomolecules with molecular weights in excess of 1000 Da. The study of these types of molecule by mass spectrometry may be subject to limitations associated with their ionization and detection and the mass range of the instrument being used. [Pg.22]

An environmental protocol has been developed to assess the significance of newly discovered hazardous substances that might enter soil, water, and the food chain. Using established laboratory procedures and C-labeled 2,3,7,8-tetra-chlorodibenzo-p-dioxin (TCDD), gas chromatography, and mass spectrometry, we determined mobility of TCDD by soil TLC in five soils, rate and amount of plant uptake in oats and soybeans, photodecomposition rate and nature of the products, persistence in two soils at 1,10, and 100 ppm, and metabolism rate in soils. We found that TCDD is immobile in soils, not readily taken up by plants, subject to photodecomposition, persistent in soils, and slowly degraded in soils to polar metabolites. Subsequent studies revealed that the environmental contamination by TCDD is extremely small and not detectable in biological samples. [Pg.105]

Crop material is homogenized with acetonitrile-water (9 1, v/v). The crop extract is centrifuged and an aliquot is rotary evaporated to a small volume. The sample is subjected to a Cig solid-phase extraction (SPE) cleanup procedure. The concentrated eluate is subjected to liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis. [Pg.1168]

An alternative to the bridge technique was recently reported for thorium analysis in silicate rocks for which both Th and Th are measured on a single lon-counting detector (Rubin 2001). With careful chemistry and mass spectrometry, °Th/ Th ratios of igneous rocks can be measured with this technique with a precision that is similar to the bridge method. The disadvantage of this technique is that °Th ion-count rates are extremely low (around 10 cps) with normal silicate thorium ratios and are therefore subject to perturbations from background variation and low-level isobaric interferences in normal samples. [Pg.36]

Although FD was one of the earliest forms of soft ionisation, poor sensitivity and limited applicability have restricted the impact of the approach in the mainstream of mass spectrometry. More recently, many of the application areas of FD and FI have been appropriated by FAB-MS, which is generally considered to be a technique that requires less expertise alternatively, laser desorption is frequently being applied. FD-MS is only used in a handful of laboratories worldwide. The technique has recently been reviewed [107], and is subject of various monographs [108,112],... [Pg.375]

Desorption chemical ionisation (DCI) mass spectrometry has been used for detecting additives extracted from polymers [51,52] by a solvent as volatile as possible. To use the DCI probe, 1 -2 iL of the sample, in solution, are applied to the probe tip, composed of a small platinum coil, and after the solvent has been allowed to evaporate at room temperature, the probe is inserted into the source. The sample is then subject to fast temperature ramping. DCI does not seem to be the most suitable mass-spectrometric method for analysis of dissolved polymer/additive matrices, because ... [Pg.702]

An electrospray is generally produced by the application of an electric field to a small flow of liquid from a capillary tube toward a counter electrode. The principles of electrospray as applicable to mass spectrometry and the mechanisms involved have been a subject of intense debate over the last decade and have been addressed even before that. This is evident from the discussions in the 2000 issue of the Journal of Mass Spectrometry (e.g., Mora11), the book by Cole,12 and several reviews.8,10 13 14 Here we present a summary encapsulating the relevant observations and direct the readers to the above articles for a more elaborate account. [Pg.234]

Fourier transform mass spectrometry is made possible by the measurement of an AC current produced from the movement of ions within a magnetic field under ultra-high vacuum, commonly referred to as ion cyclotron motion.21 Ion motion, or the frequency of each ion, is recorded to the precision of one thousandth of a Hertz and may last for several seconds, depending on the vacuum conditions. Waveform motion recorded by the mass analyzer is subjected to a Fourier transform to extract ion frequencies that yield the corresponding mass to charge ratios. To a first approximation, motion of a single ion in a magnetic field can be defined by the equation... [Pg.280]

The results for bacterial whole-cell analysis described here establish the utility of MALDI-FTMS for mass spectral analysis of whole-cell bacteria and (potentially) more complex single-celled organisms. The use of MALDI-measured accurate mass values combined with mass defect plots is rapid, accurate, and simpler in sample preparation then conventional liquid chromatographic methods for bacterial lipid analysis. Intact cell MALDI-FTMS bacterial lipid characterization complements the use of proteomics profiling by mass spectrometry because it relies on accurate mass measurements of chemical species that are not subject to posttranslational modification or proteolytic degradation. [Pg.295]

Every peak was uniform with respect to m, but each one had a distribution in block length with respect to the PEO blocks (n). To identify fractions, they were collected and subjected to mass spectrometry. The first fraction contained polyethylene glycol and block oligomers with a degree of polymerization m(PO) 1-3. The second fraction was homogeneous with respect to PO and contained m(PO) 4, while fraction 3 resulted from m(PO) = 5. [Pg.405]

Montaudo and co-workers have used direct pyrolysis mass spectrometry (DPMS) to analyse the high-temperature (>500°C) pyrolysis compounds evolved from several condensation polymers, including poly(bisphenol-A-carbonate) [69], poly(ether sulfone) (PES) and poly(phenylene oxide) (PPO) [72] and poly(phenylene sulfide) (PPS) [73]. Additionally, in order to obtain data on the involatile charred residue formed during the isothermal pyrolysis process, the pyrolysis residue was subjected to aminolysis, and then the aminolyzed residue analysed using fast atom bombardment (FAB) MS. During the DPMS measurements, EI-MS scans were made every 3 s continuously over the mass range 10-1,000 Da with an interscan time of 3 s. [Pg.423]


See other pages where Mass spectrometry Subject is mentioned: [Pg.81]    [Pg.1329]    [Pg.2725]    [Pg.29]    [Pg.475]    [Pg.478]    [Pg.479]    [Pg.298]    [Pg.172]    [Pg.573]    [Pg.270]    [Pg.45]    [Pg.47]    [Pg.55]    [Pg.123]    [Pg.76]    [Pg.152]    [Pg.206]    [Pg.1295]    [Pg.462]    [Pg.406]    [Pg.538]    [Pg.701]    [Pg.71]    [Pg.13]    [Pg.18]    [Pg.27]    [Pg.208]    [Pg.129]    [Pg.197]    [Pg.221]    [Pg.244]    [Pg.408]    [Pg.782]   