Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Ions, absorption, detection production

Neve et al. [547] digested the sample with nitric acid. After digestion the sample is reacted selectively with an aromatic o-diamine, and the reaction product is detected by flameless atomic absorption spectrometry after the addition of nickel (III) ions. The detection limit is 20mg/l, and both selenium (IV) and total selenium can be determined. There was no significant interference in a saline environment with three times the salinity of seawater. [Pg.219]

The visible absorption spectrum of a solution containing a known concentration of nitrated protein is measured in a solution buffered at pH 9.0, and the absorbance at the maximum (near 428 nm) used to calculate the nitrotyrosine content ( 428nm for the nitrophenoxide ion is 4200). The tyrosine and nitrotyrosine content of the modified protein should also be determined by amino acid analysis. If the sum of these values does not add up to the tyrosine content of the unmodified protein, intra- or intermolecular cross-linking may have occurred. The amino acid analysis may also reveal whether other side-reactions have taken place. Particular attention should be paid to the half-cystine, cysteine, methionine, histidine and tryptophan contents of the modified proteins. Polyacrylamide gel electrophoresis in the presence of sodium dodecyl sulfate offers a rapid and highly sensitive way of detecting products of intermolecular cross-linking. Such products are readily removed by gel filtration. [Pg.98]

In the ideal case for REMPI, the efficiency of ion production is proportional to the line strength factors for 2-photon excitation [M], since the ionization step can be taken to have a wavelength- and state-mdependent efficiency. In actual practice, fragment ions can be produced upon absorption of a fouitli photon, or the ionization efficiency can be reduced tinough predissociation of the electronically excited state. It is advisable to employ experimentally measured ionization efficiency line strengdi factors to calibrate the detection sensitivity. With sufficient knowledge of the excited molecular electronic states, it is possible to understand the state dependence of these intensity factors [65]. [Pg.2083]

Chromatographic methods, notably hplc, are available for the simultaneous deterrnination of ascorbic acid as weU as dehydroascorbic acid. Some of these methods result in the separation of ascorbic acid from its isomers, eg, erythorbic acid and oxidation products such as diketogulonic acid. Detection has been by fluorescence, uv absorption, or electrochemical methods (83—85). Polarographic methods have been used because of their accuracy and their ease of operation. Ion exclusion (86) and ion suppression (87) chromatography methods have recently been reported. Other methods for ascorbic acid deterrnination include enzymatic, spectroscopic, paper, thin layer, and gas chromatographic methods. ExceUent reviews of these methods have been pubHshed (73,88,89). [Pg.17]

The X-ray spectrum observed in PIXE depends on the occurrence of several processes in the specimen. An ion is slowed by small inelastic scatterings with the electrons of the material, and it s energy is continuously reduced as a frmction of depth (see also the articles on RBS and ERS, where this part of the process is identical). The probability of ionizii an atomic shell of an element at a given depth of the material is proportional to the product of the cross section for subshell ionization by the ion at the reduced energy, the fluorescence yield, and the concentration of the element at the depth. The probability for X-ray emission from the ionized subshell is given by the fluorescence yield. The escape of X rays from the specimen and their detection by the spectrometer are controlled by the photoelectric absorption processes in the material and the energy-dependent efficiency of the spectrometer. [Pg.358]

NMR and visible spectra have established that a number of S-N anions are present in such solutions.The primary reduction products are polysulfides Sx, which dissociate to polysulfur radical anions, especially the deep blue 83 ion (/Imax 620nm). In a IM solution the major S-N anion detected by NMR spectroscopy is cycZo-[S7N] with smaller amounts of the [SSNSS] ion and a trace of [SSNS]. The formation of the acyclic anion 5.23 from the decomposition of cyclo-Sjl is well established from chemical investigations (Section 5.4.3). The acyclic anions 5.22 and 5.23 have been detected by their characteristic visible and Raman spectra. It has also been suggested that a Raman band at 858 cm and a visible absorption band at 390 nm may be attributed to the [SaN] anion formed by cleavage of a S-S bond in [SSNS]. ° However, this anion cannot be obtained as a stable species when [SsN] is treated with one equivalent of PPhs. [Pg.101]

For ion TOF measurement a probe laser was used to ionize reaction products in the reaction zone. The (1 + F) resonance-enhanced multiphoton ionization (REMPI) method was adapted for H-atom detection. The necessary vacuum ultraviolet (VUV) radiation near 121.6 nm (for Lyman-a transition) can readily be generated by a frequency-tripling technique in a Kr cell.37 The sensitivity of this (1 +1 ) REMPI detection scheme is extremely high owing to the large absorption cross-section of Lyman-a transition,... [Pg.6]

Atomic absorption spectrometry is one of the most widely used techniques for the determination of metals at trace levels in solution. Its popularity as compared with that of flame emission is due to its relative freedom from interferences by inter-element effects and its relative insensitivity to variations in flame temperature. Only for the routine determination of alkali and alkaline earth metals, is flame photometry usually preferred. Over sixty elements can be determined in almost any matrix by atomic absorption. Examples include heavy metals in body fluids, polluted waters, foodstuffs, soft drinks and beer, the analysis of metallurgical and geochemical samples and the determination of many metals in soils, crude oils, petroleum products and plastics. Detection limits generally lie in the range 100-0.1 ppb (Table 8.4) but these can be improved by chemical pre-concentration procedures involving solvent extraction or ion exchange. [Pg.333]

High-performance liquid chromatography coupled with fluorescence detection [106, 107] or ion-exchange high-performance liquid chromatography with detection by graphite furnace atomic absorption spectroscopy [108] proved to be sensitive methods, but may lack from limitations in separation power and ease of identification of unknown products. [Pg.420]

The major anions and cations in seawater have a significant influence on most analytical protocols used to determine trace metals at low concentrations, so production of reference materials in seawater is absolutely essential. The major ions interfere strongly with metal analysis using graphite furnace atomic absorption spectroscopy (GFAAS) and inductively coupled plasma mass spectroscopy (ICP-MS) and must be eliminated. Consequently, preconcentration techniques used to lower detection limits must also exclude these elements. Techniques based on solvent extraction of hydrophobic chelates and column preconcentration using Chelex 100 achieve these objectives and have been widely used with GFAAS. [Pg.50]

Bio)chemical reactions may take place prior to or after the continuous separation module and are intended to enhance or facilitate mass transfer, detection or both. The earliest and simplest approach to integrated analytical steps in continuous-flow systems involves a combination of chemical reactions and continuous separations [4,5]. Such is the case with the formation of soluble organic chelates of metal ions in liquid-liquid extractions with the ligand initially dissolved in the organic stream [6], the formation and dissolution of precipitates [7], the formation of volatile reaction products in gas difiusion [8] and that of volatile hydrides in atomic absorption spectro-... [Pg.50]

Time-resolved laser flash ESR spectroscopy generates radicals with nonequilibrium spin populations and causes spectra with unusual signal directions and intensities. The signals may show absorption, emission, or both and be enhanced as much as 100-fold. Deviations from Boltzmann intensities, first noted in 1963, are known as chemically induced dynamic electron polarization (CIDEP). Because the splitting pattern of the intermediate remains unaffected, the CIDEP enhancement facilitates the detection of short-lived radicals. A related technique, fluorescence detected magnetic resonance (FDMR) offers improved time resolution and its sensitivity exceeds that of ESR. The FDMR experiment probes short-lived radical ion pairs, which form reaction products in electronically excited states that decay radiatively. ... [Pg.213]


See other pages where Ions, absorption, detection production is mentioned: [Pg.236]    [Pg.413]    [Pg.165]    [Pg.220]    [Pg.103]    [Pg.1576]    [Pg.238]    [Pg.220]    [Pg.678]    [Pg.63]    [Pg.125]    [Pg.805]    [Pg.431]    [Pg.370]    [Pg.160]    [Pg.362]    [Pg.366]    [Pg.457]    [Pg.112]    [Pg.200]    [Pg.94]    [Pg.528]    [Pg.116]    [Pg.392]    [Pg.507]    [Pg.104]    [Pg.457]    [Pg.298]    [Pg.299]    [Pg.199]    [Pg.56]    [Pg.106]    [Pg.316]    [Pg.48]    [Pg.81]    [Pg.83]    [Pg.334]   
See also in sourсe #XX -- [ Pg.48 ]




SEARCH



Ion product

Ions, absorption, detection

© 2024 chempedia.info