Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Ionization methods, mass chemical

Busch, K.L. Chemical Noise in Mass Spectrometry. Part 11 - Effects of Choices in Ionization Methods on Chemical Noise. Spectroscopy 2003,18, 56-62. [Pg.407]

APCI [14] is an analogous ionization method to chemical ionization (Cl) a significant difference between the two is that APCI occurs at atmospheric pressure and has its primary applications for the ionization of low mass compounds. APCI is not suitable for the analysis of thermally labile compounds. In APCI, the analyte solution is introduced into a pneumatic nebulizer and desolvated in a heated quartz tube before interacting with the corona discharge. The corona discharge produces primary and N by electron ioniza-... [Pg.173]

A connnon feature of all mass spectrometers is the need to generate ions. Over the years a variety of ion sources have been developed. The physical chemistry and chemical physics communities have generally worked on gaseous and/or relatively volatile samples and thus have relied extensively on the two traditional ionization methods, electron ionization (El) and photoionization (PI). Other ionization sources, developed principally for analytical work, have recently started to be used in physical chemistry research. These include fast-atom bombardment (FAB), matrix-assisted laser desorption ionization (MALDI) and electrospray ionization (ES). [Pg.1329]

A third method for generating ions in mass spectrometers that has been used extensively in physical chemistry is chemical ionization (Cl) [2]. Chemical ionization can involve the transfer of an electron (charge transfer), proton (or otlier positively charged ion) or hydride anion (or other anion). [Pg.1330]

Some mild methods of ionization (e.g., chemical ionization. Cl fast-atom bombardment, FAB electrospray, ES) provide molecular or quasi-molecular ions with so little excess of energy that little or no fragmentation takes place. Thus, there are few, if any, normal fragment ions, and metastable ions are virtually nonexistent. Although these mild ionization techniques are ideal for yielding molecular mass information, they are almost useless for providing details of molecular structure, a decided disadvantage. [Pg.228]

For solids, there is now a very wide range of inlet and ionization opportunities, so most types of solids can be examined, either neat or in solution. However, the inlet/ionization methods are often not simply interchangeable, even if they use the same mass analyzer. Thus a direct-insertion probe will normally be used with El or Cl (and desorption chemical ionization, DCl) methods of ionization. An LC is used with ES or APCI for solutions, and nebulizers can be used with plasma torches for other solutions. MALDI or laser ablation are used for direct analysis of solids. [Pg.280]

An on-line chromatography/atmospheric pressure chemical ionization tandem mass spectrometry (LC-APCI/MS/MS) methods was developed for rapid screen of pharmacokinetics of different drugs, including 5 (98RCM1216). The electron impact mass spectrum of 5 and ethyl 9,10-difluoro-3-methyl-7-oxo-2,3-dihydro-7Ff-pyrido[l,2,3- fe]-l,4-benzoxazine-6-carboxylate was reported (97MI28). Electron impact/Fourier transform... [Pg.268]

When optimum experimental conditions have been obtained, all of the mobile phase is removed before the analyte(s) are introduced into the mass spectrometer for ionization. As a consequence, with certain limitations, it is possible to choose the ionization method to be used to provide the analytical information required. This is in contrast to the other LC-MS interfaces which are confined to particular forms of ionization because of the way in which they work. The moving belt can therefore provide both electron and chemical ionization spectra, yielding both structural and molecular weight information. [Pg.136]

Stereochemical aspects in mass spectrometry have aroused more and more interest. El mass spectra of stereoisomers are practically indistinguishable. However, the use of soft ionization methods (chemical ionization, field ionization, etc.) accompanied by tandem mass spectrometry allows important and reliable conclusions on the molecular structures to be drawn. [Pg.146]

MS involves the separation of ions based on their mass-to-charge ratio (m/z). The concept was invented a century ago1 with a dramatic impact on analytical chemistry.2-3 The fundamental principle of MS requires vaporization of the molecules in the gas phase and in ionization. Early ionization methods such as electron impact (El) and chemical ionization (Cl)4-5 were limited to small organic molecules that were volatile and stable to heat and amenable to transfer into high vacuum. Introduction of the fast-atom-bombardment (FAB) method of ionization6... [Pg.227]

With few exceptions, magnetic sector instruments are comparatively large devices capable of high resolution and accurate mass determination, and suited for a wide variety of ionization methods. Double-focusing sector instruments are the choice of MS laboratories with a large chemical diversity of samples. In recent years, there is a tendency to substitute these machines by TOE or by Fourier transform ion cyclotron resonance (FT-ICR) instruments. [Pg.131]

Moody DR, Laycock JD, Huang W, Foltz RL. 2004. A high-performance liquid chromatographic-atmospheric pressure chemical ionization-tandem mass spectrometric method for determination of risperidone and 9-hydroxyr-isperidone in human plasma. J Anal Toxicol 28 494. [Pg.173]

Munch JW, Bassett MV (2004) EPA Method 521. Determination of nitrosamines in drinking water by sohd-phase extraction and capillary column gas chromatography with large volume injection and chemical ionization tandem mass spectrometry (MS/MS), U.S. EPA, Cincinnati, OH. Available at www.epa.gov/nerlcwww/m 521.pdf... [Pg.130]

The purpose of the MS techniques is to detect charged molecular ions and fragments separated according to their molecular masses. Most flavonoid glycosides are polar, nonvolatile, and often thermally labile. Conventional MS ionization methods like electron impact (El) and chemical ionization (Cl) have not been suitable for MS analyses of these compounds because they require the flavonoid to be in the gas phase for ionization. To increase volatility, derivatization of the flavonoids may be performed. However, derivatization often leads to difficulties with respect to interpretation of the fragmentation patterns. Analysis of flavonoid glycosides without derivatization became possible with the introduction of desorption ionization techniques. Field desorption, which was the first technique employed for the direct analysis of polar flavonoid glycosides, has provided molecular mass data and little structural information. The technique has, however, been described as notorious for the transient... [Pg.68]

A striking feature of the ILs is their low vapor pressure. This, on the other hand, is a factor hampering their investigation by MS. For example, a technique like electron impact (El) MS, based on thermal evaporation of the sample prior to ionization of the vaporized analyte by collision with an electron beam, has only rarely been applied for the analysis of this class of compounds. In contrast, nonthermal ionization methods, like fast atom bombardment (FAB), secondary ion mass spectrometry (SIMS), atmospheric pressure chemical ionization (APCI), ESI, and MALDI suit better for this purpose. Measurement on the atomic level after burning the sample in a hot plasma (up to 8000°C), as realized in inductively coupled plasma (ICP) MS, has up to now only rarely been applied in the field of IE (characterization of gold particles dissolved in IE [1]). This method will potentially attract more interest in the future, especially, when the coupling of this method with chromatographic separations becomes a routine method. [Pg.373]

The development of mass spectrometric ionization methods at atmospheric pressures (API), such as the atmospheric pressure chemical ionization (APCI)99 and the electrospray ionization mass spectrometry (ESI-MS)100 has made it possible to study liquid-phase solutions by mass spectrometry. Electrospray ionization mass spectrometry coupled to a micro-reactor was used to investigate radical cation chain reaction is solution101. The tris (p-bromophenyl)aminium hexachloro antimonate mediated [2 + 2] cycloaddition of trans-anethole to give l,2-bis(4-methoxyphenyl)-3,4-dimethylcyclobutane was investigated and the transient intermediates 9 + and 10 + were detected and characterized directly in the reacting solution. However, steady state conditions are necessary for the detection of reactive intermediates and therefore it is crucial that the reaction must not be complete at the moment of electrospray ionization to be able to detect the intermediates. [Pg.92]

Fredline VF, Taylor PJ, Dodds HM, Johnson AG (1997) A reference method for the analysis of aldosterone in blood by high-performance liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry. Anal Biochem 252 308-313... [Pg.601]


See other pages where Ionization methods, mass chemical is mentioned: [Pg.684]    [Pg.60]    [Pg.160]    [Pg.564]    [Pg.578]    [Pg.37]    [Pg.32]    [Pg.119]    [Pg.330]    [Pg.328]    [Pg.329]    [Pg.361]    [Pg.702]    [Pg.719]    [Pg.417]    [Pg.170]    [Pg.229]    [Pg.331]    [Pg.355]    [Pg.381]    [Pg.452]    [Pg.154]    [Pg.444]    [Pg.670]    [Pg.100]    [Pg.240]    [Pg.70]    [Pg.85]    [Pg.269]    [Pg.1032]    [Pg.875]   


SEARCH



Chemical ionization

Chemical ionization methods

Ionization methods, mass

Ionized chemical

Mass chemical ionization

© 2024 chempedia.info