Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Ionization methods, mass

A connnon feature of all mass spectrometers is the need to generate ions. Over the years a variety of ion sources have been developed. The physical chemistry and chemical physics communities have generally worked on gaseous and/or relatively volatile samples and thus have relied extensively on the two traditional ionization methods, electron ionization (El) and photoionization (PI). Other ionization sources, developed principally for analytical work, have recently started to be used in physical chemistry research. These include fast-atom bombardment (FAB), matrix-assisted laser desorption ionization (MALDI) and electrospray ionization (ES). [Pg.1329]

The ion current resulting from collection of the mass-separated ions provides a measure of the numbers of ions at each m/z value (the ion abundances). Note that for this ionization method, all ions have only a single positive charge, z = 1, so that m/z = m, which means that masses are obtained directly from the measured m/z values. Thus, after the thermal ionization process, m/z values and abundances of ions are measured. The accurate measurement of relative ion abundances provides highly accurate isotope ratios. This aspect is developed more fully below. [Pg.46]

A major advantage of the TOF mass spectrometer is its fast response time and its applicability to ionization methods that produce ions in pulses. As discussed earlier, because all ions follow the same path, all ions need to leave the ion source at the same time if there is to be no overlap between m/z values at the detector. In turn, if ions are produced continuously as in a typical electron ionization source, then samples of these ions must be utihzed in pulses by switching the ion extraction field on and off very quickly (Figure 26.4). [Pg.192]

For solids, there is now a very wide range of inlet and ionization opportunities, so most types of solids can be examined, either neat or in solution. However, the inlet/ionization methods are often not simply interchangeable, even if they use the same mass analyzer. Thus a direct-insertion probe will normally be used with El or Cl (and desorption chemical ionization, DCl) methods of ionization. An LC is used with ES or APCI for solutions, and nebulizers can be used with plasma torches for other solutions. MALDI or laser ablation are used for direct analysis of solids. [Pg.280]

When mass spectrometry was first used as a routine analytical tool, El was the only commercial ion source. As needs have increased, more ionization methods have appeared. Many different types of ionization source have been described, and several of these have been produced commercially. The present situation is such that there is now only a limited range of ion sources. For vacuum ion sources, El is still widely used, frequently in conjunction with Cl. For atmospheric pressure ion sources, the most frequently used are ES, APCI, MALDI (lasers), and plasma torches. [Pg.282]

Ionization Method Type of Molecular Ion Formed Good Molecular Mass Information Abundant Fragment Ions MS/MS Needed for Structural Information Accurate Values for Isotope Ratios... [Pg.285]

Usually, FAB yields molecular or quasi-molecular ions, which have little excess of internal energy and therefore do not fragment. This ionization method is mild and good for obtaining molecular mass (molecular weight) information. [Pg.386]

TOF mass spectrometry is ideally suited to those ionization methods that inherently produce ions in pulses, as with pulsed laser desorption or Cf-radionuclide ionization. [Pg.406]

In its simplest form, a mass spectrometer is an instmment that measures the mass-to-charge ratios ml of ions formed when a sample is ionized by one of a number of different ionization methods (1). If some of the sample molecules are singly ionized and reach the ion detector without fragmenting, then the ml ratio of these ions gives a direct measurement of the molecular weight. The first instmment for positive ray analysis was built by Thompson (2) in 1913 to show the existence of isotopic forms of the stable elements. Later, mass spectrometers were used for precision measurements of ionic mass and abundances (3,4). [Pg.539]

The appHcation of modem methods of analyses such as gc, low ionization voltage mass spectrometry, high pressure Hquid chromatography (hplc), and nmr has greatly increased knowledge of coal-tar composition without materially altering the quaHtative picture. [Pg.343]

This article discusses why one would choose nonresonant multiphoton ionization for mass spectrometry of solid surfaces. Examples are given for depth profiling by this method along with thermal desorption studies. [Pg.569]

Low ionizing potentials or soft ionization methods are necessary to observe the parent ions in the mass spectra of many S-N compounds because of their facile thermal decomposition. Mass spectrometry has been used to investigate the thermal breakdown of S4N4 in connection with the formation of the polymer (SN). On the basis of the appearance potentials of various S Ny fragments, two important steps were identified ... [Pg.47]

An on-line chromatography/atmospheric pressure chemical ionization tandem mass spectrometry (LC-APCI/MS/MS) methods was developed for rapid screen of pharmacokinetics of different drugs, including 5 (98RCM1216). The electron impact mass spectrum of 5 and ethyl 9,10-difluoro-3-methyl-7-oxo-2,3-dihydro-7Ff-pyrido[l,2,3- fe]-l,4-benzoxazine-6-carboxylate was reported (97MI28). Electron impact/Fourier transform... [Pg.268]

Unfortunately, not every compound shows a molecular ion in its mass spectrum. Although M+ is usually easy to identify if it s abundant, some compounds, such as 2,2-dimelhylpropane, fragment so easily that no molecular ion is observed (Figure 12.3). In such cases, alternative "soft" ionization methods that do not use electron bombardment can prevent or minimize fragmentation. [Pg.411]

Most biochemical analyses by MS use either electrospray ionization (ESI) or matrix-assisted laser desorption ionization (MALD1), typically linked to a time-of-flight (TOF) mass analyzer. Both ESI and MALDl are "soft" ionization methods that produce charged molecules with little fragmentation, even with biological samples of very high molecular weight. [Pg.417]

Chapter 12, Structure Determination Mass Spectrometiy and Infrared Spectroscopy—A new Section 12.4 discusses mass spectrometry of biological molecules, focusing on time-of-flight instruments and soft ionization methods such as MAI.DI. [Pg.1337]

Verification of the molecular weight of thiirene dioxides by mass spectrometry, employing the conventional electron-impact (El) ionization method, has been unsuccessful due to the absence or insignificant intensity of molecular ion peaks in their mass spectra. The base peak is rather characteristic, however, and corresponds to the formation of the disubstituted acetylene ion by loss of sulfur dioxide91 (equation 3). [Pg.397]

Various ionization methods were used to bombard phenol-formaldehyde oligomers in mass spectroscopic analysis. The molecular weights of resole resins were calculated using field desorption mass spectroscopy of acetyl-derivatized samples.74 Phenol acetylation was used to enable quantitative characterization of all molecular fractions by increasing the molecular weights in increments of 42. [Pg.408]

For many years, electron ionization, then more usually known as electron impact, was the only ionization method used in analytical mass spectrometry and the spectra encountered showed exclusively the positively charged species produced during this process. Electron ionization also produces negatively charged ions although these are not usually of interest as they have almost no structural significance. Other ionization techniques, such as Cl, FAB, thermospray, electrospray and APCI, however, can be made to yield negative ions which are of analytical utility. [Pg.56]

Ashcroft, A. E., Ionization Methods in Organic Mass Spectrometry, RSC Analytical Spectroscopy Monograph, The Royal Society of Chemistry, Cambridge, UK, 1997. [Pg.90]


See other pages where Ionization methods, mass is mentioned: [Pg.684]    [Pg.1107]    [Pg.17]    [Pg.684]    [Pg.1107]    [Pg.17]    [Pg.1331]    [Pg.2060]    [Pg.4]    [Pg.27]    [Pg.60]    [Pg.136]    [Pg.160]    [Pg.243]    [Pg.253]    [Pg.261]    [Pg.281]    [Pg.283]    [Pg.545]    [Pg.545]    [Pg.564]    [Pg.573]    [Pg.137]    [Pg.578]    [Pg.18]    [Pg.1029]    [Pg.1029]    [Pg.41]    [Pg.490]    [Pg.37]   


SEARCH



Ionization mass spectrometric methods

Ionization method for liquid chromatography mass spectrometry

Ionization methods, for mass

Ionization methods, for mass spectrometry

Ionization methods, mass adductions

Ionization methods, mass atmospheric pressure

Ionization methods, mass cationic species

Ionization methods, mass chemical

Ionization methods, mass cluster ions

Ionization methods, mass identification

Ionization methods, mass impurities

Ionization methods, mass isotope patterns

Ionization methods, mass matrix-assisted laser

Ionization methods, mass measurements

Ionization methods, mass multiply charged ions

Ionization methods, mass photoionization

Ionization methods, mass series

Ionization methods, mass structures

Ionization methods, mass unimolecular

Liquid chromatography-mass ionization methods

Mass spectrometer ionization methods

Mass spectrometer, choice ionization methods

Mass spectrometry ionization methods

Mass spectrometry soft-ionization methods

Matrix-assisted laser desorption/ionization-imaging mass methods

Quadrupole mass spectrometer, ionization method

© 2024 chempedia.info