Iodide interference

The reaction is a sensitive one, but is subject to a number of interferences. The solution must be free from large amounts of lead, thallium (I), copper, tin, arsenic, antimony, gold, silver, platinum, and palladium, and from elements in sufficient quantity to colour the solution, e.g. nickel. Metals giving insoluble iodides must be absent, or present in amounts not yielding a precipitate. Substances which liberate iodine from potassium iodide interfere, for example iron(III) the latter should be reduced with sulphurous acid and the excess of gas boiled off, or by a 30 per cent solution of hypophosphorous acid. Chloride ion reduces the intensity of the bismuth colour. Separation of bismuth from copper can be effected by extraction of the bismuth as dithizonate by treatment in ammoniacal potassium cyanide solution with a 0.1 per cent solution of dithizone in chloroform if lead is present, shaking of the chloroform solution of lead and bismuth dithizonates with a buffer solution of pH 3.4 results in the lead alone passing into the aqueous phase. The bismuth complex is soluble in a pentan-l-ol-ethyl acetate mixture, and this fact can be utilised for the determination in the presence of coloured ions, such as nickel, cobalt, chromium, and uranium. [Pg.684]

In this method, sodium azide solution is added before acidification into the sample mixture containing Mn4+ flocculent. Azide prevents any possible reaction of nitrite with iodide. Interference from Fe3+ is overcome by adding a small amount of KF solution (1 mL of 40% soln.) before acidification. [Pg.190]

Thiocyanates and iodides interfere and, if present, must be removed either with excess of solid Ag2S04 or with dilute AgNOa solution before adding the acetic acid and thiourea. [Pg.312]

Bromides and iodides interfere because of the liberated halogen the test is not trustworthy in the presence of chromates, sulphites, thiosulphates, iodates, cyanides, thiocyanates, hexacyanoferrate(II) and (III) ions. All of these anions may be removed by adding excess of nitrate-free Ag2S04 to an aqueous solution (or sodium carbonate extract), shaking vigorously for 3-4 minutes, and filtering the insoluble silver salts, etc. [Pg.335]

Chloride is oxidized with potassium periodate in a dilute sulphurie acid solution. The solution of KIO4 in H2SO4 is first heated to distil off any chlorine formed from ehloride impurities in the reagents. The optimum acid concentration for the Methyl Red colour reaction with chlorine is 1 M H2SO4. Bromide and iodide interfere in this method. The presence of 5 pg of Br" increases the results by 60-70% in the determination of 5 pg of Cl. Positive errors owing to iodide are smaller and less reproducible, than those owing to bromide. [Pg.153]

Ions which form precipitates with silver nitrate in acid medium, i.e., bromide and iodide, interfere in turbidimetric determinations. [Pg.154]

Doubts were expressed on DPASV sets for Pb which were suspected to be due to iodide interferences. [Pg.241]

Iodide interferes with the TSH system as the fimit-ing factor in thyroid hormone synthesis. In iodine deficiency, low thyroid hormone synthesis and secretion lead to increased TSH secretion and thyroid stimulation. [Pg.303]

The determination of chloride involves the precipitation of chloride with silver nitrate, dissolution of the precipitate in ammonia, and determination of silver in the resulting solution by FAAS using air-acetylene or air-hydrogen flames. Standard silver nitrate solutions in ammonia are used for calibration since bromide and iodide interfere in the determination of chloride. [Pg.136]

The behavior of antimony salts toward sulfuric acid solutions of hydroxyanthraquinones is analogous to that of boric acid they must be oxidized to antimony by means of chlorine water. Larger amounts of colored ions (Fe+ , Cu+2, Ni+, Cr+ etc.) make it difficult to detect the color change of the reagent solutions. Be+ ions lower the sensitivity of the test. Iodides interfere by releasing iodine they can be removed by precipitation with Ag2S04. Oxidizing acids impair the test. [Pg.138]

Thiocyanates and/or iodides interfere with the sensitive Pmssian blue test for ferrocyanides when carried out in a micro test tube or on a spot plate. There is simultaneous formation of red ferrithiocyanate or free iodine, which interfere with the decisive detection of small amounts of Prussian blue. If, however, the test is carried out on filter paper impregnated with ferric chloride, no difficulty is experienced because of thiocyanates or iodides. A capillary separation succeeds through the fact that ferric thiocyanate is readily decomposed by mercuric chloride, sodium fluoride, or sodium thiosulfate. If there is danger of interference by ferricyanide, the second procedure should be followed. [Pg.276]

Selectivity Due to the chemical nature of the precipitation process, precipitants are usually not selective for a single analyte. For example, silver is not a selective precipitant for chloride because it also forms precipitates with bromide and iodide. Consequently, interferents are often a serious problem that must be considered if accurate results are to be obtained. [Pg.255]

The iodide method can also be appHed to the analysis of other manganese species, but mixtures of permanganate, manganate, and MnO interfere with one another in the iodometric method. [Pg.524]

Ferrous Sulfdte Titration. For deterrnination of nitric acid in mixed acid or for nitrates that are free from interferences, ferrous sulfate titration, the nitrometer method, and Devarda s method give excellent results. The deterrnination of nitric acid and nitrates in mixed acid is based on the oxidation of ferrous sulfate [7720-78-7] by nitric acid and may be subject to interference by other materials that reduce nitric acid or oxidize ferrous sulfate. Small amounts of sodium chloride, potassium bromide, or potassium iodide may be tolerated without serious interference, as can nitrous acid up to 50% of the total amount of nitric acid present. Strong oxidizing agents, eg, chlorates, iodates, and bromates, interfere by oxidizing the standardized ferrous sulfate. [Pg.47]

The hberated iodine is measured spectrometricaHy or titrated with Standard sodium thiosulfate solution (I2 +28203 — 2 1 VS Og following acidification with sulfuric acid buffers are sometimes employed. The method requires measurement of the total gas volume used in the procedure. The presence of other oxidants, such as H2O2 and NO, can interfere with the analysis. The analysis is also technique-sensitive, since it can be affected by a number of variables, including temperature, time, pH, iodide concentration, sampling techniques, etc (140). A detailed procedure is given in Reference 141. [Pg.503]

Chloride. Chloride is common in freshwater because almost all chloride salts are very soluble in water. Its concentration is generally lO " to 10 M. Chloride can be titrated with mercuric nitrate. Diphenylcarbazone, which forms a purple complex with the excess mercuric ions at pH 2.3—2.8, is used as the indicator. The pH should be controlled to 0.1 pH unit. Bromide and iodide are the principal interferences, whereas chromate, ferric, and sulfite ions interfere at levels greater than 10 mg/L. Chloride can also be deterrnined by a colorimetric method based on the displacement of thiocyanate ion from mercuric thiocyanate by chloride ion. The Hberated SCN reacts with ferric ion to form the colored complex of ferric thiocyanate. The method is suitable for chloride concentrations from 10 to 10 M. [Pg.231]

An ion-selective electrode is available for chloride analysis chloride can be measured potentiometrically at 10 -1 M. Iodide and sulfide are the principal interferences. [Pg.231]

Bromide ndIodide. The spectrophotometric determination of trace bromide concentration is based on the bromide catalysis of iodine oxidation to iodate by permanganate in acidic solution. Iodide can also be measured spectrophotometricaHy by selective oxidation to iodine by potassium peroxymonosulfate (KHSO ). The iodine reacts with colorless leucocrystal violet to produce the highly colored leucocrystal violet dye. Greater than 200 mg/L of chloride interferes with the color development. Trace concentrations of iodide are determined by its abiUty to cataly2e ceric ion reduction by arsenous acid. The reduction reaction is stopped at a specific time by the addition of ferrous ammonium sulfate. The ferrous ion is oxidi2ed to ferric ion, which then reacts with thiocyanate to produce a deep red complex. [Pg.232]

The most common colorimetric technique involves a reaction between ammonia and a reagent containing mercuric iodide in potassium iodide (Messier reagent) to form a reddish-brown complex. Turbidity, color, and hardness are possible interferences that can be removed by preliminary distiHation at pH 9.5. [Pg.232]

Peracid Analysis. Peracid concentrations can be measured in a product or in the bath by use of a standard iodide / thiosulfate titration (60). With preformed peracids or peracids formed via perhydrolysis care must be exercised to minimize the interference of hydrogen peroxide, present intentionally as a component of the perhydrolysis reaction or as a result of the hydrolysis of the peracid (87,88) as shown in equation 18. [Pg.146]

Although ethereal solutions of methyl lithium may be prepared by the reaction of lithium wire with either methyl iodide or methyl bromide in ether solution, the molar equivalent of lithium iodide or lithium bromide formed in these reactions remains in solution and forms, in part, a complex with the methyllithium. Certain of the ethereal solutions of methyl 1ithium currently marketed by several suppliers including Alfa Products, Morton/Thiokol, Inc., Aldrich Chemical Company, and Lithium Corporation of America, Inc., have been prepared from methyl bromide and contain a full molar equivalent of lithium bromide. In several applications such as the use of methyllithium to prepare lithium dimethyl cuprate or the use of methyllithium in 1,2-dimethyoxyethane to prepare lithium enolates from enol acetates or triraethyl silyl enol ethers, the presence of this lithium salt interferes with the titration and use of methyllithium. There is also evidence which indicates that the stereochemistry observed during addition of methyllithium to carbonyl compounds may be influenced significantly by the presence of a lithium salt in the reaction solution. For these reasons it is often desirable to have ethereal solutions... [Pg.106]

Discussion. The theory of the titration of cyanides with silver nitrate solution has been given in Section 10.44. All silver salts except the sulphide are readily soluble in excess of a solution of an alkali cyanide, hence chloride, bromide, and iodide do not interfere. The only difficulty in obtaining a sharp end point lies in the fact that silver cyanide is often precipitated in a curdy form which does not readily re-dissolve, and, moreover, the end point is not easy to detect with accuracy. [Pg.358]

Fluoride ion, and weak acids and bases do not interfere, but nitrate, nitrite, perchlorate, thiocyanate, chromate, chlorate, iodide, and bromide do. Since analysis of almost all boron-containing compounds requires a preliminary treatment which ultimately results in an aqueous boric acid sample, this procedure may be regarded as a gravimetric determination of boron. [Pg.476]

Determination of nitrate as nitron nitrate Discussion. The mono-acid base nitron, C20H16N4, forms a fairly insoluble crystalline nitrate, C20H 16N4,HN03 (solubility is 0.099 g L 1 at about 20 °C), which can be used for the quantitative determination of nitrates [see Section 11.11(E)]. The sulphate and acetate are soluble so that precipitation may be made in sulphuric or acetic (ethanoic) acid solution. Perchlorates (0.08 g), iodides (0.17 g), thiocyanates (0.4 g), chromates (0.6 g), chlorates (1.2g), nitrites (1.9 g), bromides (6.1 g), hexacyanoferrate(II), hexacyanoferrate(III), oxalates, and considerable quantities of chlorides interfere, and should be absent. The figures in parentheses are the approximate solubilities of the nitron salts in g L-1 at about 20 °C. [Pg.484]

The method is clearly confined to those cases where the test substance does not react with either of the components of the reagent, nor with the hydrogen iodide which is formed during the reaction with water the following compounds interfere in the Karl Fischer titration. [Pg.637]

Discussion. The procedure is based on the formation of yellow tetraiodo-antimonate(III) acid (HSbI4) when antimony(III) in sulphuric acid solution is treated with excess of potassium iodide solution. Spectrophotometric measurements may be made at 425 nm in the visible region or, more precisely, at 330 nm in the ultraviolet region. Appreciable amounts of bismuth, copper, lead, nickel, tin, tungstate, and molybdate interfere. [Pg.680]

Dithiol is a less selective reagent than thiocyanate for molybdenum. Tungsten interferes most seriously but does not do so in the presence of tartaric acid or citric acid (see Section 17.34). Tin does not interfere if the absorbance is read at 680 nm. Strong oxidants oxidise the reagent iron(III) salts should be reduced with potassium iodide solution and the liberated iodine removed with thiosulphate. [Pg.693]

The amount of reddish-purple acid-chloranilate ion liberated is proportional to the chloride ion concentration. Methyl cellosolve (2-methoxyethanol) is added to lower the solubility of mercury(II) chloranilate and to suppress the dissociation of the mercury(II) chloride nitric acid is added (concentration 0.05M) to give the maximum absorption. Measurements are made at 530nm in the visible or 305 nm in the ultraviolet region. Bromide, iodide, iodate, thiocyanate, fluoride, and phosphate interfere, but sulphate, acetate, oxalate, and citrate have little effect at the 25 mg L 1 level. The limit of detection is 0.2 mg L 1 of chloride ion the upper limit is about 120 mg L . Most cations, but not ammonium ion, interfere and must be removed. [Pg.700]

Other useful solid-state electrodes are based on silver compounds (particularly silver sulfide). Silver sulfide is an ionic conductor, in which silver ions are the mobile ions. Mixed pellets containing Ag2S-AgX (where X = Cl, Br, I, SCN) have been successfiilly used for the determination of one of these particular anions. The behavior of these electrodes is determined primarily by the solubility products involved. The relative solubility products of various ions with Ag+ thus dictate the selectivity (i.e., kt] = KSp(Agf)/KSP(Aw)). Consequently, the iodide electrode (membrane of Ag2S/AgI) displays high selectivity over Br- and Cl-. In contrast, die chloride electrode suffers from severe interference from Br- and I-. Similarly, mixtures of silver sulfide with CdS, CuS, or PbS provide membranes that are responsive to Cd2+, Cu2+, or Pb2+, respectively. A limitation of these mixed-salt electrodes is tiiat the solubility of die second salt must be much larger than that of silver sulfide. A silver sulfide membrane by itself responds to either S2- or Ag+ ions, down to die 10-8M level. [Pg.159]

Colorimetric procedures used In steroid assays are often subject to drug Interference. In the determination of 17-Ketosterolds by the Zimmerman reaction, drugs with the 17-Keto basic structure such as ascorbic acid, morphine and reserplne will cause Increased values. In the determination of 17,21 -dlhydroxysterolds by the Porter-Sllber reaction the dlhydroxy-acetone chain Is the reactive unit. Drugs like meprobamate, chloral hydrate, chloropromazlne and potassium Iodide will Interfere with this reaction and cause elevated values. In the colorimetric determination of vanlllylmandellc acid (VMA) by a dlazo reaction, drugs like methocarbamol and methyl dopa cause... [Pg.274]

Other solutions to dealing with interferences in the detection of H O have included the use of a copperfll) diethyldithiocarbamate precolumn to oxidize the sample before it reaches the immobilized enzyme, as well as the use of a palladium/gold sputtered electrode which catalyzes the oxidation of hydrogen peroxide In addition, peroxidase has been used to catalyze the reaction between hydrogen peroxide and iodide ferrocyanide and organo-fluorine compounds Am-... [Pg.64]

Walters [24] examined the effect of chloride on the use of bromide and iodide solid state membrane electrodes, and he calculated selectivity constants. Multiple linear regression analysis was used to determine the concentrations of bromide, fluorine, and iodide in geothermal brines, and indicated high interferences at high salt concentrations. The standard curve method was preferred to the multiple standard addition method because of ... [Pg.65]


See other pages where Iodide interference is mentioned: [Pg.340]    [Pg.396]    [Pg.47]    [Pg.232]    [Pg.127]    [Pg.87]    [Pg.781]    [Pg.443]    [Pg.699]    [Pg.866]    [Pg.189]    [Pg.387]    [Pg.563]    [Pg.331]    [Pg.65]    [Pg.651]   
See also in sourсe #XX -- [ Pg.152 , Pg.154 ]