LC-MB-MS has routinely been used for poly-mer/additive analysis [523]. Due to problems associated with this interface (e.g. sensitivity and analyte desorption), it is not considered to be a general analytical tool its use was mainly relegated to specific cases. Few studies have been published on the MB interface, now extinct. [Pg.501]

Electrospray ionization (ESI), a very powerful MS ionization mode, has been coupled with liquid chromatography becoming a popular tool in biomolecular analysis and drug analysis applications [1], Use of HPLC or ultra performance liquid chromatography (UPLC) combined with a mass spectrometry through the interface—ESI has become a powerful and routinely used analytical tool for many fields in scientific research, pharma industry, healthcare, and clinical diagnostic applications. [Pg.401]

Today, mass spectrometry offers an attractive alternative as a detector to HPLC. Newer techniques for linking HPLC systems with mass spectrometers directly via atmospheric pressure chemical ionization (APCI) and electrospray interfaces should see an expansion of this analytical tool in the analysis of confectionery fats, a field in which it has not yet been applied. Triacylglycerols... [Pg.74]

The versatility of the SPR technique has been shown by a vast amount of publications in the past decades the method has matured into a well-accepted analytical tool for the characterization of interfaces and thin films as well as for the sensitive detection of interfacial biomolecular interaction. With a significant input from engineering, SPR has reached a decent signal-to-noise level with a lower limit for a reliable signal detection corresponding to an effective layer of about 0.3 A [6], which is sufficient for most thin film studies. However, the intrinsic label-free characteristic of SPR detection technique still imposes limitation on further sensitivity improvement, especially if the analysis involves small molecules. [Pg.56]

The interfacing of CE with ESI mass spectrometry has progressed substantially in recent years. On-line CE/MS has been widely used for both qualitative and quantitative analysis of many chemically diverse molecules. This method becomes a useful and sensitive analytical tool for the separation, quantification and identification of biological, therapeutic, environmental and other important classes of chemical analytes. The developments of CE/MS have been reviewed [22-26]. [Pg.228]

Further aspects of surface analysis are the accuracy of determining composition or structural parameters. For practical purposes the possibility of combining different tools is very important. As an example, the STM is difficult to combine in situ with other techniques. Most surface analytical tools require ultrahigh-vacuum (UHV) for their operation, hence solid-liquid interfaces are hardly accessible. Another practical aspect concerns the analysis of surface processes, for... [Pg.1]

Amphiphilic isotherm (65) analysis can be used for the determination of the interfacial structure. An amphiphilic molecule, which consists of two moieties with opposing properties such as a hydrophilic polar head and a hydrophobic hydrocarbon tad, should be used as an analytical tool located at the interface. Pheophytin a is a well-known surfactant molecule that contain a hydrophobic chain (phytol) and a hydrophilic head group. The value of p, less than 1.0, indicates that adsorbed molecules of n-octane are parallel to the interface between octane and water [23] (Fig. 11). Substitution of one adsorbed octane molecule requires about 4 to 5 adsorbed pheophytin... [Pg.179]

Vibrational spectroscopy represents two physically different, yet complementary spectroscopic techniques IR and Raman spectroscopy. Although both methods have been utilised for many years, recent advances in electronics, computer technologies and sampling made Fourier transform infrared (FTIR) and Raman (FT-Raman) one of the most powerful and versatile analytical tools. Enhanced sensitivity and surface selectivity allows non-invasive, no-vacuum molecular level analysis of surface and interfaces. Emphasis is placed on recent advances in attenuated total reflectance (ATR), step-scan photoacoustic (SS-PA), Fourier transform infrared (FTIR) and FT-Raman microscopies, as utilised to the analysis of polymeric surfaces and interfaces. A combination of these probes allows detection of molecular level changes responsible for macroscopic changes in three dimensions from various depths. 7 refs. [Pg.67]

Currently, the main breakthrough in environmental analysis is observed in the application of LC-MS and LC-MS/MS techniques. One of the obstacles to routine analytical applications of LC-MS had been the unavailability of rugged and reliable LC-MS interfaces. The development of atmospheric pressure ionization (API) overcame such limitations as poor structural information or sensitivity seen with thermospray (TSP) or particle-beam (PB). API is used as a generic term for soft ionization obtained by different interface/ionization types, such as APCI and electrospray (ESI) that operate under atmospheric pressure conditions. Today, LC-MS has become a routine analytical tool, allowing the detection of polar and nonvolatile compounds not amenable to GC analysis. [Pg.2922]

It cannot be overemphasized that the O SHA is an extremely valuable analytical tool that concentrates on the human interface with the system from both operations and maintenance standpoints. Therefore, because of the critical requirement of ensuring that operations and maintenance personnel are protected from any hazards in their tasks, the importance of a properly performed O SHA is of paramount concern in the system safety analysis process. [Pg.97]

The iProXpress knowledge system consists of (i) a data warehouse with integrated protein information, (ii) analytical tools for protein sequence analysis and functional annotation, and (iii) a graphical user interface for categorization and visualization of expression data. The design of the iProXpress knowledge system... [Pg.217]


See other pages where Interface analysis, analytical tools is mentioned: [Pg.531]    [Pg.415]    [Pg.821]    [Pg.549]    [Pg.740]    [Pg.25]    [Pg.5]    [Pg.358]    [Pg.531]    [Pg.45]    [Pg.32]    [Pg.158]    [Pg.8]    [Pg.283]    [Pg.59]    [Pg.111]    [Pg.37]    [Pg.11]    [Pg.124]    [Pg.328]    [Pg.1207]    [Pg.1589]    [Pg.4]    [Pg.417]    [Pg.139]    [Pg.10]    [Pg.286]    [Pg.145]    [Pg.512]    [Pg.198]    [Pg.247]    [Pg.211]    [Pg.587]    [Pg.157]    [Pg.390]    [Pg.89]    [Pg.490]   
See also in sourсe #XX -- [ Pg.293 ]




SEARCH



Analysis Tools

Analytical Analyses

Analytical tools

Interface analysis

Interface analysis, analytical

© 2024 chempedia.info