Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

In quantification

To quantitate proteins from staining, a densitometer aided by computer software is used to evaluate band areas of samples compared to band areas of a standard curve. Amido black, Coomassie Brilliant Blue, and silver stains are all appHcable for use in quantification of proteins. [Pg.183]

Relative photoionization cross sections for molecules do not vary gready between each other in this wavelength region, and therefore the peak intensities in the raw data approximately correspond to the relative abundances of the molecular species. Improvement in quantification for both photoionizadon methods is straightforward with calibration. Sampling the majority neutral channel means much less stringent requirements for calibrants than that for direct ion production from surfaces by energetic particles this is especially important for the analysis of surfaces, interfaces, and unknown bulk materials. [Pg.563]

The accuracy achievable by the ratio method amounts to approximately 5-10 atom% when ionization edges of the same type are used, i. e. only K edges or only L edges, whereas the error in quantification increases to +15-20 atom% for the use of dissimilar edges. Improvement of the quantification accuracy up to approximately 1 atom% is possible if standards are used. [Pg.67]

Although SFE and SFC share several common features, including the use of a superaitical fluid as the solvent and similar instrumentation, their goals are quite distinct. While SFE is used mainly for the sample preparation step (extraction), SFC is employed to isolate (chr-omatography) individual compounds present in complex samples (11 -15). Both techniques can be used in two different approaches off-line, in which the analytes and the solvent are either vented after analysis (SFC) or collected (SFE), or on-line coupled with a second technique, thus providing a multidimensional approach. Off-line methods are slow and susceptible to solute losses and contamination the on-line coupled system makes possible a deaease in the detection limits, with an improvement in quantification, while the use of valves for automation results in faster and more reproducible analyses (16). The off-line... [Pg.137]

Analysis is most frequently done qualitatively since there are problems in quantification (Reed, 1973). Although intensity is approximately proportional to mass concentration of a given element there are significant deviations, depending on which other elements are present. [Pg.369]

As you are no doubt aware, integrals are one of the key parameters in the interpretation of proton spectra and are pivotal in quantification. They measure the area under a peak and this is directly proportional to the number of protons (in the case of proton NMR) in that environment. Most software will automatically try to identify the peaks in your spectrum and integrate them for you. If you need to do it yourself, then it is a fairly trivial matter of defining the start and end point of the integrals of interest. The only complication is that you may need to tweak the slope and bias of the integral. This should be unnecessary if you have got the phase and baseline of your spectrum correct. If you find that you need to adjust slope and bias, we suggest that you go back and try to sort out baseline and phase a bit better. [Pg.39]

Proteins biotinylated with this reagent will have a characteristic absorbance band at 354 nm, which can be used to determine accurately the number of biotin groups per molecule. No other biotinylation compound has such built-in quantification capability. This feature eliminates the need to consume conjugate by doing a HABA assay to test for the level of biotin incorporation (Chapter 23, Section 7). [Pg.730]

The quantification capability is normally limited by the detector and/or the ion source. The MCP that is often utilized in TOF instruments cannot fully handle the ion currents that are produced in MALDI and are often saturated to some extent. With other ion sources, such as SIMS, the detection system is less strained so the detector is less limiting. Instead the ion source will limit the quality in quantification. Magnetic sectors and also qudmpoles are more often utilized when quantification is important. [Pg.45]

Discussion of the negative impacts experienced with TSCA made several allusions to the long-term positive aspects of these effects. Where difficulty was experienced in quantification of negative impacts, even more difficulty is experienced with the... [Pg.151]

The standard addition procedure is another method for recognising and overcoming potential matrix effects in quantification. Both alternatives, FIA—MS or FIA—MS—MS, can be performed using this procedure. Despite the increased expenditure because of a multiplication in analyses, the FIA approach combined with standard addition remains the faster technique even with the application of specific analytical MS—MS techniques such as product-, parent- or neutral loss scans applying selected reaction monitoring (SRM). The greatest drawback of this technique is that the compounds to be quantified must... [Pg.179]

REFERENCE COMPOUNDS IN QUANTIFICATION OF SURFACTANTS, THEIR METABOLITES AND REACTION BY-PRODUCTS... [Pg.476]

In principle, Mq can be determined through the first point in time domain for t = 0 or by integration of L. However, under experimental conditions distortions in the acquired time signal (e.g., due to eddy currents) are transferred to the frequency domain by Fourier transformation and can result in significant differences in quantification. A straightforward quantification method in the frequency domain is simply to determine the total integrated area under a resonance in a distinct frequency range of the spectrum. This method works well for spectra with well separated resonance lines and without... [Pg.30]

Principal air quality issues of local, national, and international concern are listed below in increasing order of difficulty based on the number of different types of pollutants and problems in quantification of the risks the pollutants pose (Cooper et al., 1997) ... [Pg.35]

Masanetz, C., Blank, I and Grosch, W. 1995. Synthesis of [2H6]-3-mercapto-3-methylbutyl formate to be used as internal standard in quantification assays. Flavour Fragrance J. 10 9-14. [Pg.1023]

Sen, A. and Grosch, W. 1991. Synthesis of six deu-terated sulfur containing odorants to be used as internal standards in quantification assays. Z Lebensm.-Unters. -Forsch.A 192 541-547. [Pg.1024]

Many research experiments have been conducted to determine the presence and quantity of SPA in foods. As literature reviews show, a particular emphasis has developed in the recovery procedures for antioxidants and in quantification procedures, including colorimetric methods, spec-trophotometric methods in the UV region, paper and thin-layer chromatographic methods, gas... [Pg.602]

However, the nucleic acid-based assays for the detection of food pathogens show problems regarding the sensitivity of the polymerase enzyme to environmental contaminants, difficulties in quantification, the generation of false-positives through the detection of naked nucleic acids, non-viable microorganisms or contamination of samples in the laboratory, and may limit the use of PCR for the direct detection of microbial contamination. [Pg.460]

Kloskowski, R., Ftihr, F., and Mittelstaedt, W. (1986a). Formation of bound residues of [benzene ring-U-14C]- anilazine and [triazine-U-14C]-anilazine inparabraunerde (Alfisol soil) and their availibility to maize. In Quantification, Nature, and Bioavailability of Bound 14C-Pesticide Residues in Soil, Plants, and Food. Int. Atomic Energy Agency, Vienna, 65-70. [Pg.138]

Techniques applying test compounds labeled with stable isotopes are applied as well (Browne et al. 1993). However, they have not found broad acceptance in substituting radioisotopes in this field due to their restrictions in quantification of unknown metabolites. [Pg.501]

Neuhoff, V., Stamm, R., Pardowitz, I., Arold, N., Ehrhardt, W., Taube, D. (1990). Essential problems in quantification of proteins following colloidal staining with coomassie brilliant blue dyes in polyacrylamide gels, and their solution. Electrophoresis 11,101-117. [Pg.55]

Often, low levels of carotenoids in biological samples provide significant challenges in quantification by HPLC-PDA alone. Electrochemical detection (ECD) has been successful in quantifying low concentrations of carotenoids (MacCrehan and Schonberger, 1987 Finckh et ah, 1995 Yamashita and Yamamoto, 1997). More information about ECD can be found in Chapter 2. ECD has also been successful in quantifying carotenoid isomers in foods, plasma, prostate tissue, cervical tissue, and buccal mucosal cells (Ferruzzi et ah, 1998,2001 Allen et ah, 2003 Unlu et ah, 2007). Electrochemical array detection for all-irans - 3-carotene has been reported to be 10 fmol on column, which is approximately 100-1000 times more sensitive than UVA is detectors (Ferruzzi et ah, 1998). [Pg.117]


See other pages where In quantification is mentioned: [Pg.287]    [Pg.227]    [Pg.335]    [Pg.357]    [Pg.220]    [Pg.224]    [Pg.344]    [Pg.53]    [Pg.162]    [Pg.188]    [Pg.188]    [Pg.16]    [Pg.452]    [Pg.622]    [Pg.25]    [Pg.501]    [Pg.277]    [Pg.732]    [Pg.204]    [Pg.756]    [Pg.15]    [Pg.142]    [Pg.318]    [Pg.108]    [Pg.400]    [Pg.277]   
See also in sourсe #XX -- [ Pg.368 ]




SEARCH



Problems in quantification

Quantification in SNMS

Quantification in plasma

Quantification in serum

Quantification of Analytical Data via Calibration Curves in Mass Spectrometry Using Certified Reference Materials or Defined Standard Solutions

Quantification of D-Lactic Acid Content in PLA

Quantification of Individual Lipid Species in Lipidomics

Quantification of Noble Metals in Biological and Environmental Samples

Quantification of Pt, Pd, and Rh in Environmental Materials

Quantification of Transitions in Fly Ash-Zeolite and NaOH-Water Systems

Relative Quantification of Catalytic Activity in Combinatorial Libraries by Emissivity-Corrected Infrared Thermography

Two-Step Quantification Approach Used in MDMS-SL

© 2024 chempedia.info