Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Glucose detection with biosensor

J. Tkac, E. Sturdik and P. Gemeiner, Novel glucose non-interference biosensor for lactose detection based on galactose oxidase-peroxidase with and without co-immobilised beta-galactosidase, Analyst, 125(7) (2000) 1285-1289. [Pg.293]

The discussion of sensors, especially those used for continuous monitoring, will be based on biosensors using glucose oxidase with electrochemical detection. The sensors generally adhere to the following sequence of reactions of enzyme, E, and mediator, M ... [Pg.10]

The nano-array biosensor based on GOD-Ti02/Ti nanotube array electrode exhibits the reinforced current response in a bioelectrocatalysis and electro-reduction process, which can promote amperometric detection of glucose concentration with a high sensitivity and a low detection limit. In particular, such a nano-array biosensor based on GOD-Ti02/Ti nanotube array electrode can be potentially used for a better detection of somatic blood glucose for... [Pg.257]

Bresler H S era/ 1992 Application of capacitive affinity biosensors HIV antibody and glucose detection Biosensor Design and Application ed P R Mathewson and J W Finley (Washington, DC American Chemical Society) pp 89-104 Keese C R and Giaver I 1994 A biosensor that monitors cell morphology with electrical fields IEEE Eng. Med. Biol. Mag. 13 402-8 Bao J-Z er al 1993 Impedance spectroscopy of human erythrocytes system calibration and nonlinear modelling IEEE Trans. Biomed. Eng. BME-40 364-78... [Pg.479]

Os (bipyridyl)2(poly-4-vinylpyridine)ioCl]Cl, on an underlying platinum electrode, followed by an outer layer of electropolymerized polypyrrole containing glucose oxidase. This biosensor was capable of detecting glucose linearly up to 50 mM, with a reported sensitivity of 12.2 nA/mM. [Pg.1504]

Small molecules such as dopamine,ascorbic acid, amino acids, nucleotides, NADH, and glucose have been successfully detected with QD-based biosensors. FRET-based fluorescence microscopy and electrochemistry are the most commonly used methods for small biomolecule detection using QD-based biosensors. ... [Pg.192]

Biosensors Using Atomic Force Microscopes, Rgure 4 (a) Reactions for giucose detection with a biosensor based on glucose oxidase (GOD),... [Pg.113]


See other pages where Glucose detection with biosensor is mentioned: [Pg.116]    [Pg.219]    [Pg.315]    [Pg.164]    [Pg.411]    [Pg.68]    [Pg.149]    [Pg.571]    [Pg.94]    [Pg.352]    [Pg.15]    [Pg.116]    [Pg.165]    [Pg.186]    [Pg.194]    [Pg.222]    [Pg.226]    [Pg.252]    [Pg.256]    [Pg.257]    [Pg.325]    [Pg.335]    [Pg.176]    [Pg.45]    [Pg.45]    [Pg.380]    [Pg.68]    [Pg.729]    [Pg.510]    [Pg.87]    [Pg.157]    [Pg.156]    [Pg.38]    [Pg.1041]    [Pg.249]    [Pg.144]    [Pg.245]    [Pg.282]    [Pg.386]    [Pg.386]    [Pg.103]   