Generator system, diesel

These catalysts contained promoters to minimise SO2 oxidation. Second-generation systems are based on a combined oxidation catalyst and particulate trap to remove HC and CO, and to alleviate particulate emissions on a continuous basis. The next phase will be the development of advanced catalysts for NO removal under oxidising conditions. Low or 2ero sulfur diesel fuel will be an advantage in overall system development. [Pg.173]

As can be seen from this table, the major cost factor for such a system is attributed to the operation of the diesel generator, therefore diesel fuel consumption accounts for approximately 74% of total annualised costs. [Pg.123]

Diesel Generator System. The cool clean gas can be combusted in a naturally aspirated 250 HP Deutz diesel engine (Model F12L413F) which has been modified for burning wood gas. [Pg.372]

The benefits of AFE PWM variable frequency drives coupled to mine hoists indicates that this will be the preferred application for the foreseeable future. When powered by off-grid diesel generation systems, particular attention paid to design specifications of drive transformer or input reactors, generators, load banks, harmonic filter banks, and power system controls can avoid potential power system problems and ensure a successful system implementation. Individual equipment manufacturers need to have an understanding of overall system design... [Pg.188]

Loss of offsite power Reactor protection system functions Diesel generator system functions... [Pg.650]

Currently, most base stations are grid tied with the electricity grid providing prime power. Backup comes in the form of diesel generators, and to a much lesser extent some form of renewable - battery hybrid system. Off-grid base stations are much less common but when they are installed the norm is a two-diesel generator system, where one acts as the primary with the backup power provided by the other. [Pg.1111]

Instantaneous maps of the mixture fraction, temperature, and main combustion products (H2O, CO2, CO) are shown in Figure 7.4 for the n-heptane. N-heptane is a fuel commonly used in engines. Its cetane number is approximately 56, which is typical for diesel fuel, because its properties of ignition and combustion are similar to those of diesel fuel [7]. The n-heptane has received substantial interest because it is a major component of the primary reference fuel (PRF) in internal combustion engine studies [6] and is considered a surrogate for liquid hydrocarbon fuels used in many propulsion and power generation systems [8]. [Pg.174]

Similarly, the flow from a compressed cyfinder can be properly converted to provide the desired parts-per-miUion concentration when diluted with the flow from the generation system (Figure 4.16). Gasoline engine and diesel engine exhaust can be piped into the laboratory and the flow can be controlled by nse of a stopcock to give the proper volume dilution. [Pg.96]

The fuel resistance of POM copolymers is rated only for temperatures up to approx. 60 °C. For new-generation diesel vehicles, that is not enough. Since the introduction of so-called common-rail technology in a new generation of fuel injection systems, diesel fuel can heat up far above 100 °C [964]. [Pg.750]

The DOE staff also performed dynamic response spectrum analyses for two pipe lines considered representative of the cooling water lines in the K-Reactor. The lines analyzed were the cooling water supply line for heat exchanger 4B and the Raw Water Inlet line for the Caterpillar Diesel Generator System. [Pg.191]

This subsection concerns the evaluation of the following mechanical and electrical equipment (including the electrical components associated with pumps and valves) (1) the PWS, including the Septifoil system (2) the SSS (3) the CWS (4) the MRS (5) the CWRDS (6) the diesel generator system (7) equipment for automatic actuation of the.SSS (8) filter, compartment latches and chocks and (9) instrumentation required for monitoring tank level, pump flow indicators, and bulk moderator temperature following a DBE. [Pg.194]

Recirculation Pump. Emergency Diesel Generator System... [Pg.198]

The Recirculation Pump Emergency Diesel Generator System included several auxiliary components (not the diesel generator units themselves) which were seismically qualified by testing for the restart program. Examples of these equipment items are relays, the automatic transfer switch, disconnect switches, and transformers. [Pg.199]


See other pages where Generator system, diesel is mentioned: [Pg.509]    [Pg.160]    [Pg.46]    [Pg.292]    [Pg.189]    [Pg.319]    [Pg.310]    [Pg.509]    [Pg.248]    [Pg.371]    [Pg.182]    [Pg.403]    [Pg.70]    [Pg.10]    [Pg.12]    [Pg.709]    [Pg.310]    [Pg.180]    [Pg.362]    [Pg.816]    [Pg.1158]    [Pg.425]    [Pg.96]    [Pg.95]    [Pg.276]    [Pg.587]    [Pg.90]    [Pg.191]    [Pg.194]    [Pg.198]    [Pg.610]    [Pg.215]    [Pg.1]    [Pg.170]    [Pg.240]    [Pg.474]    [Pg.475]   
See also in sourсe #XX -- [ Pg.384 ]