Solvent Sensitive Gels

The immersion of glass electrodes in strongly dehydrating media should be avoided. If the electrode is used in solvents of low water activity, frequent conditioning in water is advisable, as dehydration of the gel layer of the surface causes a progressive alteration in the electrode potential with a consequent drift of the measured pH. Slow dissolution of the pH-sensitive membrane is unavoidable, and it eventually leads to mechanical failure. Standardization of the electrode with two buffer solutions is the best means of early detection of incipient electrode failure. [Pg.466]

This means, in practice, that when employing a polar solvent with n-heptane (or any other paraffin for that matter) to reduce the retention, there will be a dramatic reduction in retention over the concentration range of about 0-2%w/v. However, subsequent changes in solute retention with polar solvent concentration will be relatively small. This will be true for any polar solute and was experimentally verified by Scott and Kucera for solutions of ethyl acetate, tetrahydrofuran and n-propanol in n-heptane. The very sensitive relationship between solvent concentration and retention at very low concentrations makes the phase system very difficult to make reproducible. This problem is one of the factors that deter analysts from using silica gel as a stationary phase for the separation of polar solutes. It is very satisfactory, however, for the separation of polarizable and weakly polar substances that can be eluted by paraffin/methylene dichloride or similar types of solvent mixtures. [Pg.65]

For the synthesis of quinolines and isoquinolines the classical approaches are the Skraup and the Bischler-Napieralski reactions. The reaction of substituted anilines with different carbonyl compounds in acid medium has been reported to be accelerated under microwave irradiation to give differently substituted quinolines and dihydro quinolines [137]. Although the yields are much better and the conditions are milder than under conventional heating, the acidity of the medium may prevent the preparation of acid-sensitive compounds. Thus, alternative approaches have been investigated. Substituted anilines and alkyl vinyl ketones reacted under microwave irradiation on the surface of sihca gel doped with InCU without solvent [137] to furnish good yields of quinohnes 213 (Scheme 77). [Pg.252]

Solid-surface room-temperature phosphorescence (RTF) is a relatively new technique which has been used for organic trace analysis in several fields. However, the fundamental interactions needed for RTF are only partly understood. To clarify some of the interactions required for strong RTF, organic compounds adsorbed on several surfaces are being studied. Fluorescence quantum yield values, phosphorescence quantum yield values, and phosphorescence lifetime values were obtained for model compounds adsorbed on sodiiun acetate-sodium chloride mixtures and on a-cyclodextrin-sodium chloride mixtures. With the data obtained, the triplet formation efficiency and some of the rate constants related to the luminescence processes were calculated. This information clarified several of the interactions responsible for RTF from organic compounds adsorbed on sodium acetate-sodium chloride and a-cyclodextrin-sodium chloride mixtures. Work with silica gel chromatoplates has involved studying the effects of moisture, gases, and various solvents on the fluorescence and phosphorescence intensities. The net result of the study has been to improve the experimental conditions for enhanced sensitivity and selectivity in solid-surface luminescence analysis. [Pg.155]

It is fruitless to attempt detailed study of a phenomenon whose products are not well identified. It is unfortunately frequently noted in the literature, especially in cases of column chromatography, that fractions are only identified as to the chemical operations which brought them to light. Fractions are identified, for example, only by the solvent used. Speculations as to the composition of the radioactive solutes in such solutions can seldom be really reliable, and the presence of an unexpected radioactive species is in such cases undetectable. It is also important in reading the literature to watch out for cases in which the chemical yields of the carriers have not been measured. Extensive decomposition can often occur on silica gel and alumina columns, especially when photosensitive or moisture sensitive compounds are used. For these reasons much of the information now existing in the literature must be regarded as only exploratory, awaiting the development of better analytical methods for separation, purification, identification and determination of the products —known or expected. [Pg.91]

Analyses for the Saxitoxins. Early methods for analysis of the saxitoxins evolved from those used for toxin isolation and purification. The principal landmarks in the development of preparative separation techniques for the saxitoxins were 1) the employment of carboxylate cation exchange resins by Schantz et al. (82) 2) the use of the polyacrylamide gel Bio-Gel P2 by Buckley and by Shimizu (5,78) and 3) the development by Buckley of an effective TLC system, including a new solvent mixture and a new visualization technique (83). The solvent mixture, designated by Buckley as "E", remains the best for general resolution of the saxitoxins. The visualization method, oxidation of the saxitoxins on silica gel TLC plates to fluorescent degradation products with hydrogen peroxide and heat, is an adaptation of the Bates and Rapoport fluorescence assay for saxitoxin in solution. Curiously, while peroxide oxidation in solution provides little or no response for the N-l-hydroxy saxitoxins, peroxide spray on TLC plates is a sensitive test for all saxitoxin derivatives with the C-12 gemdiol intact. [Pg.47]

The full potenhal of RDCs, however, can be seen by the incorporation of RDC data in structure calculations. Several programs hke XPLOR-NIH, DISCOVER or GROM ACS allow the incorporation of RDCs as angular or combined angular and distance dependent restraints. Several studies on sugars have been reported (see, e.g. Ref [43] and references therein) and Fig. 9.8 shows the comparison of three structural models for the backbone of the cyclic undecapeptide cyclosporin A, derived from X-ray crystahography, ROE data in CDCI3 as the solvent, and RDCs and ROEs obtained in a PDMS/CDCfi stretched gel [22]. Due to the sensitivity to... [Pg.223]

For multi-analyte and/or multi-matrix methods, it is not possible to validate a method for all combinations of analyte, concentration and type of sample matrix that may be encountered in subsequent use of the method. On the other hand, the standards EN1528 andEN 12393 consist of a range of old multi-residue methods. The working principles of these methods are accepted not only in Europe, but all over the world. Most often these methods are based on extractions with acetone, acetonitrile, ethyl acetate or n-hexane. Subsequent cleanup steps are based on solvent partition steps and size exclusion or adsorption chromatography on Florisil, silica gel or alumina. Each solvent and each cleanup step has been successfully applied to hundreds of pesticides and tested in countless method validation studies. The selectivity and sensitivity of GC combined with electron capture, nitrogen-phosphorus, flame photometric or mass spectrometric detectors for a large number of pesticides are acceptable. [Pg.113]

Some kinds of chromatography require relatively little optimization. In gel permeation chromatography, for example, once the pore size of the support and number of columns is selected, it is only rarely necessary to examine in depth factors such as solvent composition, temperature, and flow rate. Optimization of affinity chromatography is similarly straightforward. In RPLC or IEC, however, retention is a complex and sensitive function of mobile phase composition column type, efficiency, and length flow rate gradient rate and temperature. [Pg.32]

The latest innovation is the introduction of ultra-thin silica layers. These layers are only 10 xm thick (compared to 200-250 pm in conventional plates) and are not based on granular adsorbents but consist of monolithic silica. Ultra-thin layer chromatography (UTLC) plates offer a unique combination of short migration distances, fast development times and extremely low solvent consumption. The absence of silica particles allows UTLC silica gel layers to be manufactured without any sort of binders, that are normally needed to stabilise silica particles at the glass support surface. UTLC plates will significantly reduce analysis time, solvent consumption and increase sensitivity in both qualitative and quantitative applications (Table 4.35). Miniaturised planar chromatography will rival other microanalytical techniques. [Pg.226]

B Kabra, SH Gehrke. Rate limiting steps for solvent sorption and desorption by microporous stimuli-sensitive absorbent gels. In FL Buchholz, NA Peppas, eds. Superabsorbent Polymers Science and Technology. ACS Symp Ser 573. Washington, DC American Chemical Society, 1994, pp 76-87. [Pg.547]

RFS Freitas, EL Cussler. Temperature sensitive gels as extraction solvents. Chem Eng Sci 41 97-105, 1986. [Pg.549]

Picer and Picer [357] evaluated the application ofXAD-2, XAD-4, and Tenax macroreticular resins for concentrations of chlorinated insecticides and polychlorinated biphenyls in seawater prior to analysis by electron capture gas chromatography. The solvents that were used eluted not only the chlorinated hydrocarbons of interest but also other electron capture sensitive materials, so that eluates had to be purified. The eluates from the Tenax column were combined and the non-polar phase was separated from the polar phase in a glass separating funnel. Then the polar phase was extracted twice with n-pentane. The -pentane extract was dried over anhydrous sodium sulfate, concentrated to 1 ml and cleaned on an alumina column using a modification of the method described by Holden and Marsden. The eluates were placed on a silica gel column for the separation of PCBs from DDT, its metabolites, and dieldrin using a procedure described by Snyder and Reinert [359] and Picer and Abel [360]. [Pg.421]


See other pages where Solvent Sensitive Gels is mentioned: [Pg.52]    [Pg.95]    [Pg.108]    [Pg.175]    [Pg.305]    [Pg.280]    [Pg.428]    [Pg.2]    [Pg.52]    [Pg.397]    [Pg.68]    [Pg.26]    [Pg.3]    [Pg.320]    [Pg.354]    [Pg.181]    [Pg.42]    [Pg.24]    [Pg.293]    [Pg.320]    [Pg.85]    [Pg.68]    [Pg.204]    [Pg.89]    [Pg.813]    [Pg.231]    [Pg.522]    [Pg.539]    [Pg.218]    [Pg.296]    [Pg.173]    [Pg.68]    [Pg.540]    [Pg.436]   
See also in sourсe #XX -- [ Pg.53 ]

See also in sourсe #XX -- [ Pg.53 ]